Toxicity: Skin and eye irritant. Skin sensitizer.
Moderately toxic by ingestion.
Primary Routes of Entry: Skin, ingestion, inhalation.
Signs and symptoms
of Exposure: May cause eye irritation and other allergic
responses such as skin sensitization or dermatitis
Existing Conditions
Aggravated by Exposure: None known
Literature Referenced Carcinogen
Ingredients Target Organ and Other Health Effects NTP IARC OSHA
RESIN
Epoxy resin ALG IRR NO NO NO
Barium sulfate LUN NO NO NO
Calcium carbonate NUI NO NO NO
Iron oxide No Data NO NO NO
SILICA, AMORPHOUS TREATED NUI NO N/A NO
HARDENER
Calcium carbonate NUI NO NO NO
Polymercaptan No Data NO NO NO
Barium sulfate LUN NO NO NO
Aluminum silicate No Data NO NO NO
DIETHYLENETRIAMINE ALG IRR NO NO NO
Heptakis(dipropyleneglycol)-
triphosphate No Data NO NO NO
TITANIUM DIOXIDE IRR NUI NO NO NO
SILICA, AMORPHOUS TREATED NUI NO N/A NO
-------------------------------------------------------------------------------
LOCTITE CORPORATION 09/11/96
ROCKY HILL, CONNECTICUT 06067
EMERGENCY PHONE: (860) 571-5100
Ingestion: Do not inuce vomiting. Keep individual
calm. Obtain medical attention.
Inhalation: Remove to fresh air. If symptoms persist,
obtain medical attention.
Skin Contact: Wash thoroughly with soap and water.
Eye Contact: Flush at least 15 minutes with water. Obtain
medical attention.
5. FIRE FIGHTING MEASURES
Flash Point: More than 400癋 Method: Open cup
Recommended
Extinguishing Agents: Carbon dioxide, foam, dry chemical
Hazardous Products formed
by Fire or Thermal Decomp Irritating organic vapors
Unusual Fire or
Explosion Hazards: None
Explosive Limits:
(% by volume in air)Lower Not available
(% by volume in air)Upper Not available
6. ACCIDENTAL RELEASE MEASURES
Steps to be taken in case
of spill or leak: Scrape up as much as possible. Store in closed
containers until disposal. Do not store scrap
resin with scrap hardener.
7. HANDLING AND STORAGE
Safe Storage: Store in a cool, dry area.
DO NOT STORE SCRAP RESIN WITH SCRAP HARDENER
(Contact Loctite Customer Service 1-800-243-4874 for shelf Life information)
Handling: Avoid skin contact. Keep away from eyes.
Avoid prolonged breathing of vapors.
LOCTITE CORPORATION 09/11/96
ROCKY HILL, CONNECTICUT 06067
EMERGENCY PHONE: (860) 571-5100
Eyes: Safety glasses or goggles.
Skin: Rubber or plastic gloves.
Ventilation: Sufficient to maintain vapor concentration
below TLV.
See Section 2 for Exposure Limits.
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance: Resin: Black paste
Hardener: Beige paste
Odor: Resin: Mild
Hardener: Sulfur
Boiling Point: More than 300癋
pH: Does not apply
Solubility in Water: Insoluble
Specific Gravity Resin: 1.82
Hardener: 1.75
Volatile Organic Compound
(EPA Method 24) Not available
Vapor Pressure: Not available
Vapor Density: Not available
Evaporation Rate
(Ether = 1) Not available
10. STABILITY AND REACTIVITY
Stability: Stable
Hazardous Polymerization: Will not occur
Incompatibility: Oxidizing agents.
Hazardous Decomposition
Products (non-thermal): None
11. TOXICOLOGICAL INFORMATION
See Section 3.
12. ECOLOGICAL INFORMATION
No data available
13. DISPOSAL CONSIDERATIONS
Recommended methods of
disposal: Incinerate following EPA and local regulations.
EPA Hazardous Waste
Number D005 - May be a TCLP waste per 40CFR 261.24/Barium
LOCTITE CORPORATION 09/11/96
ROCKY HILL, CONNECTICUT 06067
EMERGENCY PHONE: (860) 571-5100
DOT (49 CFR 172)
Domestic Ground Transport
Proper Shipping Name: Unrestricted
Hazard Class or
Division: Unrestricted
Identification Number: None
Marine Pollutant: None
IATA
Proper Shipping Name: Unrestricted
Class or Division: Unrestricted
UN or ID Number: None
15. REGULATORY INFORMATION
CA Proposition 65: No Prop65 chemicals are known to be present.
16. OTHER INFORMATION
Estimated NFPA(R) Code:
Health Hazard: 2
Fire Hazard: 1
Reactivity Hazard: 0
Specific Hazard: Does not apply
Estimated HMIS(R) Code:
Health Hazard: 2
Flammability Hazard: 1
Reactivity Hazards: 0
Personal Protection: See Section 8.
NFPA is a registered trademark of the National Fire Protection Assn.
HMIS is a registered trademark of the National Paint and Coatings Assn.
Prepared By: Stephen Repetto
Title: Research Chemist, Health and Safety
Company: Loctite Corp., 1001 Tr Br Cr, Rocky Hill CT 06067
(24hr.) Phone: (860) 571-5100
Revision Date: January 22, 1996 Revision: 0015