Prepared By: An Other Building: Hilton
School: Science Room Number: CBD 1
2.0
Current Version Date Next Review Date Current Version No
1/01/2007 1/07/2007 1/12/2007
Initial Issue Date
**RA is
Hazardous in accordance
Packing n/a; n/r;
MSDS <
C.A.S. DG U.N. Exact Pack Size No. of Total
with NOHSC? Y or N Req.
Chemical Name Grp. Manufacturer Uses 5yrs old
note the main health
Number class Number Location L or Kgs packs Quantity { dat e }
I, II, III hazard
Y highly flammable, skin
2.5 L 5 12.5 May-03
Acetone 3 1090 II n/r
FLC solvent
67-64-1 APS
irritant
Ethanol 3 1170 II n/r
Y flammable 2.5 L 6 15 Jun-04
FLC solvent
64-17-5 Sigma-Aldrich
used in
Y highly toxic, mutagenic 0.5 Kg 2 1 Mar-04
Ethidium Bromide 6.1 2811 I Req
Toxic cabinet electrophoresis
1239-45-8 Sigma-Aldrich
Y highly toxic by inhalation
0.5 Kg 2 1 Sep-04
and skin contact
Sodium Azide 6.1 1687 II Req
Toxic cabinet bactericide
26628-22-8 Sigma-Aldrich
Y highly flammable,
2.5 L 5 12.5 Mar-03
possible reproductive toxin
Petroleum Spirit 60-800C 3 3295 II Req
FLC solvent
mixture Sigma-Aldrich
Y corrosive liquid and lab reagent, used for
2.5 L 5 12.5 Jun-04
Corrosives production of
vapour, causes burns,
Hydrochloric acid 8 1789 II Req
cabinet chlorides
reactive
7647-01-0 Sigma-Aldrich
Sodium Chloride n/a n/a n/a n/a
N 2.5 Kg 8 20 Jun-05
shelf glazing, curing
7647-14-5 Merck
lab reagent, used for
Picric acid Y explosive when dry 0.5 Kg 4 2 Sep-03
dedicated production of
(Trinitrophenol] 4.1 1344 I Req
cabinet chlorides
88-89-1 APS
manufacture of
Y 1L 2 2 Feb-05
20% Urea n/a n/a n/a n/a
shelf resins
57-13-6 APS
Y explosive when dry, locked
0.5L 2 1 Sep-04
Perchloric acid 70% 5.1/8 1873 I Req
cupboard dehydrating agent
7601-90-3 Sigma-Aldrich
powerful oxidiser
Y causes skin and eye
2.5 L 1 2.5 Jan-05
Phenol 6.1 1671 II Req
Toxic cabinet disinfectant
108-95-2 Sigma-Aldrich
burns, toxic
n/a = Not Applicable i.e. a risk assessment is not mandatory (e.g the substance is not hazardous nor, is the way the substance being used, hazardous)
**RA=n/a; RA=n/r; RA=Req. n/r = Not Required i.e. a separate documented risk assessment is not required as the substances is being used in accordance with the MSDS and for the purpose for which it was
intended (i.e simple and obvious assessment)
Req. = Required i.e. a separate documented risk assessment is required as the substance is being mixed or used in a manner that increases the risk controls required above
those indicated on the MSDS
Template_Chemical_Register Date Effective: 01/02/2007
Page 1 of 1
Uncontrolled document when printed Current Version: 2.1, 04/09/2007