Page 1 sur 5
MATERIAL SAFETY DATA SHEET
1.Chemical product and company identification
Trade name: RNA Instapur
References: KP-0100-01 (100ml)
Chemical name: No
Company:
Eurogentec s.a.
Parc scientifique du Sart Tilman
B-4102 Seraing, Belgium
Tel. 00 32 4 372 74 00
Fax. 00 32 4 372 75 00
2.Information on ingredients
CAS #: N/A
Hazardous ingredients:
Chemical/Common Name CAS-Number % PEL-OSHA TLV-ACGIH
PHENOL (Carbolic Acid, Hydroxybenzene) 108-95-2 <50 T5.PPM T5.PPM
GUANIDINE THIOCYANATE 593-84-0 >50 N/A N/A
NFPA HAZARD IDENTIFICATION RATING SYSTEM
HEALTH 3
FIRE 2
REACTIVITY 0
HAZARD T, CO
3.Effects of direct contact
Health Effects (Acute and Chronic)
This product may be harmful if swallowed, inhaled, or absorbed through skin. It contains Phenol that can cause severe
burns to splashed eyes or skin. Effects of overexposure may include Nausea, headache, dizziness, and dark urine. Some
studies indicate that phenol may cause cancer in laboratory animals.
Target organs include CNS, liver, spleen, and kidneys.
It also contains Guanidine THIOCYANATE that can cause eye/skin irritation.
Primary Routes of Entry
Splash on skin or in eye(s)
Medical conditions aggravated by exposure
N/A
Eurogentec Headquarters
LIEGE SCIENCE PARK ?4102 SERAING ?Belgium ?Tel: +32 4 372 76 65
Fax: +32 4 372 75 00 ?info@eurogentec.com ?www.eurogentec.com
Eurogentec North America
3347 Industrial Ct ?Suite A ?San Diego, CA 92121 ?USA ?Tel: +1 858 793 26 61
Fax: +1 858 793 26 66 ?info.usa@eurogentec.com ?www.eurogentec.com
Page 2 sur 5
MATERIAL SAFETY DATA SHEET
4.First aid
If swallowed:
Ingestion-keep victims warm and calm. Seek immediate medical assistance.
If inhaled:
Inhalation-remove victim to fresh air. Give oxygen if breathing becomes labored. Should breathing stop-give artificial
respiration.
In case of contact:
Skin contact-flush contaminated skin with large volumes of water for at least 15 minutes as contaminated clothing is
removed. Get medical attention if area remains irritated. Do not wear contaminated clothing until after it has been properly
cleaned.
In case of contact with eyes:
Eye contact flush-contaminated eye(s) with large volumes of water for at least 15 Minutes. Ensure that water gets up
under the eyelids. See medical attention (after flushing).
5.Fire fighting measures
Extinguishing media
Water Spray, CO2, Dry chemical, alcohol
Special fire fighting procedures
N/A
Unusual Fire and Explosion Hazards:
N/A
6.Accidental release measures
Steps to be taken in case material is released or spilled
Evacuate the area. Initiate cleaning up the spill using a self-contained breathing apparatus and other methods to minimize
exposure. If the product is dry mop up. If the material is in solution use an absorbent material to contain/pick up the
spilled solution, seal, label and hold for disposal.
7.handling and storage
Precautions to be taken in handling and storage
See package insert for storage information
Maintenance Precautions
N/A
Other Precautions
N/A
Eurogentec Headquarters
LIEGE SCIENCE PARK ?4102 SERAING ?Belgium ?Tel: +32 4 372 76 65
Fax: +32 4 372 75 00 ?info@eurogentec.com ?www.eurogentec.com
Eurogentec North America
3347 Industrial Ct ?Suite A ?San Diego, CA 92121 ?USA ?Tel: +1 858 793 26 61
Fax: +1 858 793 26 66 ?info.usa@eurogentec.com ?www.eurogentec.com
Page 3 sur 5
MATERIAL SAFETY DATA SHEET
8.exposure control / personal protection
Ventilation Data
Provide adequate local exhaust ventilation.
Respiratory Protection
Should not be necessary if ventilation is adequate.
Protective Gloves
Impervious gloves are to be worn to prevent skin contact.
Other Protective Equipment
Safety glasses with side shields should be worn. Eye wash stations and deluge showers should be accessible (29 CFR
1910.151 (C). Finally, a lab coat should be worn.
Other Engineering Controls
N/A
Work Practices
Good laboratory technique should be used when handling this product. Observe appropriate chemical hygiene. Avoid
contact with skin or eyes.
Hygienic Practices
Do not eat, drink or smoke while using this product. Upon completion of work activity with the reagent wash exposed body
parts with soap and water.
9.Physical and chemical properties
Boiling point (F) 180C Specific gravity (Water=1) 1.057
Vapor pressure (MMHG) N/A Percent volatile by volume (%) N/A
Vapor density (Air=1) 3.24 Evap rate (N/I=1) N/A
Solubility in Water: soluble
Flash point (Method used) 174 F (79C) Flammable limits-LEL= 1.5 UEL= 10
Appearance and odor:
Clear, bright and red liquid
10.Stability and reactivity
Stability:
Stable
Conditions to avoid stability:
Heat, flame or pressure
Incompatibilities:
Eurogentec Headquarters
LIEGE SCIENCE PARK ?4102 SERAING ?Belgium ?Tel: +32 4 372 76 65
Fax: +32 4 372 75 00 ?info@eurogentec.com ?www.eurogentec.com
Eurogentec North America
3347 Industrial Ct ?Suite A ?San Diego, CA 92121 ?USA ?Tel: +1 858 793 26 61
Fax: +1 858 793 26 66 ?info.usa@eurogentec.com ?www.eurogentec.com
Page 4 sur 5
MATERIAL SAFETY DATA SHEET
Oxidizers, Acids, Bases, Copper, Magnesium, Lead, Aluminum and other metals
Hazardous polymerization:
Hazardous polymerization should not occur
Conditions to avoid polymerization:
N/A
Hazardous Decomposition Products:
N/A
11.Toxicological information
The product should be handled with the care usual when dealing with chemicals.
For details see chapter 3
12.Ecological information
Eco-toxic effects:
Quantitative data on the ecological effect of this product are not available.
Further ecological data:
Do not allow entering waters, wastewater or soil.
13.Disposal consideration
Waste Disposal Method
Dispose of in accordance with all local, state and federal regulations.
14.Transportation information
Land transport GGVS, GGVE, ADR, RID
Classification 6.1/25c and 6.1/147b
Name 2811 Guanidium thiocyanat, 1671 Phenol
River transport ADN, ADNR
Classification not tested
See transport IMDG, GGVSee
Classification 6.1/UN 2811/PG III and 6.1/UN 1671/PGII
Ems 6.1-0
MFAG 4.2, 710
Name Guanidium thiocyanat, Phenol
Air transport ICAO, IATA
Classification 6.1/UN 2811/PG III and 6.1/UN 1671/PGII
Name Guanidium thiocyanat, Phenol
Eurogentec Headquarters
LIEGE SCIENCE PARK ?4102 SERAING ?Belgium ?Tel: +32 4 372 76 65
Fax: +32 4 372 75 00 ?info@eurogentec.com ?www.eurogentec.com
Eurogentec North America
3347 Industrial Ct ?Suite A ?San Diego, CA 92121 ?USA ?Tel: +1 858 793 26 61
Fax: +1 858 793 26 66 ?info.usa@eurogentec.com ?www.eurogentec.com
Page 5 sur 5
MATERIAL SAFETY DATA SHEET
The transport regulations are cited according to international regulations and in the form applicable in Germany
(GGVS/GGVE). Possible national deviations in the other countries are not considered.
15.Regulatory information
Code of federal regulations 29 CFR 1910.1000 and .151; 1988.
American Conference of governmental industrial hygienists TLVS; 1991-92.
16.Other information
The above information is believed to be correct but does not purport to be all-inclusive and shall be used only as a guide.
Eurogentec shall not be held liable for any damage resulting from handling or from contact with the above product. See
reverse side of invoice or packing slip for additional terms and conditions of sale.
Eurogentec Headquarters
LIEGE SCIENCE PARK ?4102 SERAING ?Belgium ?Tel: +32 4 372 76 65
Fax: +32 4 372 75 00 ?info@eurogentec.com ?www.eurogentec.com
Eurogentec North America
3347 Industrial Ct ?Suite A ?San Diego, CA 92121 ?USA ?Tel: +1 858 793 26 61
Fax: +1 858 793 26 66 ?info.usa@eurogentec.com ?www.eurogentec.com
|