Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

N/A

File Name: icorecomposites_com_EGBLCMSDS.asp

                         MATERIAL SAFETY DATA SHEET

Balsa 鈥? Lite (contourable)
EG

I-Core Composites LLC
802 23rd Street SW
Cullman, AL 35055
256-739-6627


Section I Product Identification


Product Name: Balsa 鈥? Lite (contourable)
EG

General or generic ID: Balsa wood end-grain panel, scoured, scrim backed
finished
Appearance: Tan kiln-dried wood with yellow-white or white
fiberglass scrim adhered
Odor: None
D.O.T. Hazard Classification: ORM-C no label required



Section II Hazardous Ingredients


Components: Balsa wood, non-hazardous in available state
Scrim components: Continuous filament E Glass and Ethylene Vinyl
Acetate 鈥? non-hazardous above minimum
concentrations.

Note: cutting, milling, routing, sanding or otherwise abrading this material may render
airborne components subject to PEL 鈥? TWA = 15mg/m3
Section III Physical and Chemical Characteristics


Boiling Point: N/A Vapor Pressure: N/A
Vapor Density: Solid N/A Percentage Volatility by Volume: N/A
Evaporation Rate: Nil Solubility in Water by Weight: N/A
Description: light tan wood grain Electrical conductivity: none
Solubility: Insoluble
Specific Gravity (balsa): 0.05 鈥? 0.250
Specific Gravity (scrim): 2.6


Section IV Fire and Explosion Hazard Data


Flash Point (ASTM D1929) balsa: > 400掳F (200掳C)
Flash Point (scrim): > 800掳F (425掳C)
Auto-ignition: > 750掳F (400掳C)
Melting Point (scrim): > 240掳F (115掳C)
Flammability Limits in Air: Not determined
Explosive Limits in Air: Not determined
Extinguishing Media: Water, water fog, CO2, dry chemical
Special Fire-fighting Procedures: Self-contained breathing apparatus and protective
clothing while battling sustained fire
Avoid contact with molten EVA
Unusual Fire & Explosion Hazards: Product may smolder unless doused with water
Wood dust cloud may ignite



Section V Reactivity Data


Hazardous Polymerization: Will not occur
Stability: Stable
Storage: Store at room temperature
Incompatibility: Strong oxidizers can cause ignition/burning
Conditions to Avoid: Exposure to flame, heat or ignition source
Hazardous Decomposition Products: Carbon monoxide, carbon dioxide and traces of low
molecular weight hydrocarbons and organic acids




2
Section VI Health Hazard Data


Effects of Overexposure

Eyes 鈥? Can cause mild irritation, redness, tearing

Skin 鈥? No known adverse effects, but may cause itching or allergic reaction in sensitive
persons

Breathing 鈥? Inhalation of excessive dust from product can cause asphyxiation due to
coating of lung tissue; may cause nasal dryness, irritation and obstruction; coughing,
sneezing, may occur.

Swallowing 鈥? No known adverse effect

Emergency/First Aid Procedures

Eyes -- flush eye, upper lid and lower lid with water; seek medical attention if irritation
persists

Skin -- Flush with water or wash with soap and water, do not blow. If molten EVA comes
in contact with skin, do not pull from skin, but cool with water.

Breathing 鈥? evacuate individual to clear air area, if difficulty in breathing persists,
administer oxygen, if breathing stops or asphyxia is apparent, administer CPR and call
for emergency assistance. Keep individual warm and quite.

Swallowing 鈥? drink water or, if large quantities have been ingested, seek medical
attention.

Primary Exposure Method

Contact from handling and inhalation of wood dust from sawing, sanding, routing or
abrading material

Effects of Chronic Exposure

No known adverse chronic health effects are known for this product, but enhanced
allergic conditions may occur for certain persons. No information available to us suggests
that any medical condition might be aggravated by exposure to this product. However,
wood dust has been classified as a human carcinogen (Group 1, 4/1995) by the
International Agency for Research on Cancer, such classification being based primarily



3
on evaluation of nasal cavities and Para nasal sinuses. Similarly, the American
Conference of Governmental Industrial Hygienists classifies hardwood dust as a
confirmed human carcinogen (Class 1A, 5/1996).


Section VII Precaution for Safe Handling and Use


Protective Equipment to be Used

Respiratory Protection 鈥? use of a dust/mist respirator approved by NIOSH/MSMA (TC-
21C-132) is recommended whenever use of product results in creation of dust.

Ventilation 鈥? while the product does not require special ventilation, whenever use of
product results in creation of dust, mechanical exhaust, ventilation or vacuum assisted
dust removal is recommended to prevent the potential accumulation of potentially
explosive airborne dust clouds and to decrease inhalation.

Protective Clothing 鈥? Clothing covering the arms and legs of workers is recommended as
is the wearing of goggles whenever use of product results in creation of dust.
Precautions to be Taken in Handling and Storage

Product is combustible wood and fiberglass and should be stored in cool, dry location
away from open flame, heat sources or other means of ignition.


Section VIII Waste Disposal


Contents and Hazards Associated with Waste

Balsa dust does not contain any hazardous substances. However, as stated above, dust
inhalation, or collection of dust on floors may cause injury or a hazardous condition to
exist.

Methods of Waste Disposal

Use of brooms, vacuums and dust removal systems are recommended. A shop vacuum is
a useful tool for dust and debris removal from floors and work areas.

User of product should review local, state, and federal regulations concerning health and
pollution disposal procedures to assure its compliance with disposal.




4
Section IX Additional Comments


The US Department of Occupational Safety and Health Administration (OSHA) has
determined that the presence of certain amounts and types of wood dust raises a
workplace safety issue. OSHA has established rules to address this issue that are
contained at 29 CFR 搂搂 1900 et. Seq. In accordance with these rules, we provide
customers of wood products that may produce wood dust when used for their intended
purposes this Material Safety Data Sheet.

The spill reporting information required by 40 CFR 搂 117 and 49 CFR 搂 171.8 do not
apply to this product in that it is not a hazardous substance, has no concentrations of
hazardous substances and does not require reporting of quantities of hazardous
substances.

This document was prepared in accordance with the requirements contained at 29 CFR 搂
1910.1200.


Section X Document Control


Prepared by: James Nearen
Date originally prepared: April 3, 2006
Last Revised On: April 3, 2006
Previous Revision Date: None



Section XI Disclaimer of Liability


The information and data contained herein is believed to be accurate, is similar to
information provided by other industry participants, and has been compiled from several
sources believed to be reliable.

I-Core Composites LLC makes no express or implied warranties about the accuracy or
the completeness of the information contained herein and offers it to the user as a basis
for consideration, investigation and independent verification.

I-Core Composites LLC disclaims any liability for claims by parties who use or rely on
information and data contained herein regardless of the nature of such claim, including
specifically, but without limitation, that the information contained herein was inaccurate,
incomplete or materially misleading.



5

ALL Chemical Analysis PAGES IN THIS GROUP
NAMECAS
hyne_com_au_07_SawdustNonTreatedHwd.asp N/A
hzlhx_com_msdslhx.asp N/A
298-93-1.asp 298-93-1
ifront_sekisui_co_jp_ebbls.asp N/A
2002-01-1.asp 2002-01-1
78-11-5.asp 78-11-5 118-96-7 13424-46-9 7758-97-6
icorecomposites_com_EGBLCMSDS.asp N/A
idccorp_com_roxul_minerwool.asp N/A
idimn_com_SilverShield_MSDS.asp N/A
ifa_hawaii_edu_Aluminum_Alloys.asp N/A
ifa_hawaii_edu_Chevron_Supreme_Motor_Oil_SAE_30.asp N/A
9002-84-0.asp 9002-84-0 50-00-0
5989-27-5.asp 5989-27-5
7440-50-8.asp 7440-50-8 7440-31-5 7440-48-4 7440-66-6 7440-02-0
65997-17-3.asp 65997-17-3 25104-55-6
64742-93-4.asp 64742-93-4 7704-34-9 7783-06-4
56-81-5.asp 56-81-5 111-46-6 25322-68-3 26172-55-4 102-71-6
56-40-6.asp 56-40-6 107-21-1 57-55-6 56-81-5 616-45-5 68072-38-8 9014-85-1 2634-33-5 214559-61-2
123-31-9.asp 123-31-9 22-40-4
79-10-7.asp 79-10-7 061-00-8 22-35-5 39-45-6
64-18-6.asp 64-18-6 001-00-0 23-26-4
6153-56-6.asp 6153-56-6 006-00-8
64742-94-5.asp 64742-94-5
ilrc_ucf_edu_MSDS_00000189.asp N/A
64742-88-7.asp 64742-88-7 74-98-6 64741-88-4 64742-52-5 64742-54-7 64741-96-4 471-34-1 61789-86-4 75-28-5 64742-47-8 64742-95-6 25551-13-7 95-63-6
111-76-2.asp 111-76-2 8052-41-3
images_cableorganizer_com_firebarrierMSDS.asp N/A
50800-85-6.asp 50800-85-6 7647-01-0 7732-18-5
7732-18-5.asp 7732-18-5 01333-86-4 57-55-6 100-42-5
11-01-0.asp 11-01-0
11-01-0.asp 11-01-0 25535-16-4
64742-47-8.asp 64742-47-8 66402-68-4 14808-60-7 14464-46-1 64741-44-2 68855-54-9 67-63-0 57-55-6 7732-18-5 8004-87-3
5989-27-5.asp 5989-27-5
64742-47-8.asp 64742-47-8 66402-68-4 14808-60-7 14464-46-1 64741-44-2 68855-54-9 67-63-0 57-55-6 7732-18-5 8004-87-3
5989-27-5.asp 5989-27-5
imscompany_com_sp_purgex.asp N/A
7440-02-0.asp 7440-02-0 7782-42-5
10101-97-0.asp 10101-97-0
598-63-0.asp 598-63-0 13099-33-7 10102-49-5 7631-86-9 7787-59-9
7440-02-0.asp 7440-02-0 7429-90-5
52315-07-8.asp 52315-07-8
7782-44-7.asp 7782-44-7 74-82-8 7783-06-4 630-08-0 7727-37-9
25068-38-6.asp 25068-38-6 25085-99-8 13463-67-7 14807-96-6 68515-49-1 26761-40-0
25068-38-6.asp 25068-38-6 14808-60-7 13463-67-7 78-93-3 123-86-4 1330-20-7 67-63-0
110-54-3.asp 110-54-3 63148-62-9 75-28-5 74-98-6
1314-13-2.asp 1314-13-2 68476-85-7
9002-88-4.asp 9002-88-4
7727-37-9.asp 7727-37-9
infab_org_NewMSDS.asp N/A
9002-88-4.asp 9002-88-4 25087-34-7 25213-02-9


HBCChem,Inc

Chemical Information Net chemcas.orgCopyright Reserved

Trading Lead

Leputech HPLC Laboratory