Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

9002-84-0

File Name: 9002-84-0.asp

                                               Material Safety Data Sheet
Style DX Alltra 480 PTFE Sheet
DXSeal, Inc.
Revised: November 5, 2006



Section 1 鈥? Chemical Product and Company Identification

Product Name: Style DX Alltra 480 PTFE Sheet
Product Use: Gasketing Product
Manufacturer Information: DXSeal, Inc.
DXSeal, Inc.
P.O. Box 223
Vienna, OH 44473
(330) 856-4635
Emergency Contacts: Kathy Thomas
Prepared By
Rebecca Wentzel
(330) 856-4635
Preparation Date: November 5, 2006
Supercedes:

Section 2 鈥? Composition/Ingredient Information


Component/Ingredient CAS # OSHA ACGIH Percent by
PEL PEL Weight
Barium Sulfate --- --- 10 mg/m3 <40
PTFE Resin 9002-84-0 --- >60
See Section 8 of this MSDS for exposure limit data for these ingredients

Section 3 鈥? Hazards Identification
Appearance and Odor: Off-white sheet / no odor
Route(s) of Entry:
Inhalation: NA
Skin Contact: NA
Ingestion: NA.
Eye Contact: NA
Health Hazards (Acute and Chronic): Product does not pose a health
hazard under normal conditions of use.

Carcinogenicity: NTP-No* IARC-No* OSHA-No*



1
www.dxseal.com 330-856-4635
Material Safety Data Sheet
Style DX Alltra 480 PTFE Sheet
DXSeal, Inc.
Revised: November 5, 2006



Section 4 鈥? First Aid Measures
If overcome by thermal decomposition products from a fire, move to fresh air. If
victim is unconscious, exhibits breathing difficulty or if recovery is not prompt
contact a physician for treatment.

Section 5 鈥? Fire Fighting Measures
Lower Flammability
No
Is this product flammable? Limit Not Available
Flammability
Not Applicable
Flash Point Classification Not Determined
Explosion Data 鈥?
Not Applicable
Upper Flammable Limit Sensitivity to Not Available
mechanical impact
Explosion Data 鈥?
None Not Available
Auto Ignition Temperature Sensitivity to static
discharge
Hazardous Combustion
Not Applicable
Flash Point Method Products Data Not Available

General Fire Hazards: DX Alltra 480 is flame resistant. If an ignition source is
present, Alltra will burn in atmospheres containing at least 95% oxygen. When
flame is applied to Alltra in air, it will ignite due to gaseous decomposition, but will
not continue to burn once the flame is removed.
Extinguishing Media: Dry chemical, foam, carbon dioxide, and water fog.
Fire Fighting Instructions: Self-contained breathing apparatus should be worn.
Use normal fire fighting procedures. Neoprene or other impervious gloves should
be worn when handling refuse from a fire due to the possible presence of
hydrofluoric acid.



Section 6 鈥? Accidental Release Measures
Containment Procedures: Pick up any large pieces.
Clean-Up Procedures: Collect material and place in a suitable container for
disposal as non-hazardous waste.




2
www.dxseal.com 330-856-4635
Material Safety Data Sheet
Style DX Alltra 480 PTFE Sheet
DXSeal, Inc.
Revised: November 5, 2006



Section 7 鈥? Handling and Storage
General Storage: Use good and safe workplace practices when handling this
material.
Handling: Handling and use in a manner consistent with good industrial &
manufacturing techniques and practices.
Storage: Store in un-opened containers under cool and dry conditions.
Storage Temperature: Not Determined
Loading Temperature: Not Applicable

Section 8 鈥? Exposure Controls / Personal Protection
Engineering Controls: Over exposure to thermal decomposition may cause
temporary symptoms of polymer fume fever. Some symptoms may be delayed 1
to 2 days. If overcome by thermal decomposition due to fire, remove patient to
fresh air.
Personal Protective Equipment:
Eyes and Face: Wear safety glasses with side shields or goggles when
handling this material.
Skin: Use appropriate workplace clothing and procedures when using this
material
Respiratory: If airborne dust is present, use a NIOSH approved particulate
respirator. (3M 8710)
Comments This product contains no known OSHA hazardous ingredients per 29
CFR 1910.1200

Hazardous Ingredients OSHA PEL ACGIH TLV Other


Section 9 鈥? Physical and Chemical Properties

Off-White Sheet None
Appearance Odor
Gasketing Sheet 7
Physical State pH in water
Not Applicable
Vapor Density Melting Point 327掳C / 620掳F
Not Applicable Not Applicable
Vapor Pressure Freezing Point
2.88 Insoluble
Specific Gravity Solubility
Not Applicable Not Applicable
Odor Threshold Boiling Point
Evaporation Volatiles
Rate (By Weight)
Not Applicable Not Applicable



3
www.dxseal.com 330-856-4635
Material Safety Data Sheet
Style DX Alltra 480 PTFE Sheet
DXSeal, Inc.
Revised: November 5, 2006



Section 10 鈥? Chemical Stability & Reactivity Information
Stability: Stable 鈥? Direct flame will ignite product. Avoid heating product above
500掳F without adequate ventilation. Shelf life is measured in years.
Reactivity Hazards: : In service, avoid incompatible media such as molten alkali
metals, fluorine, and certain fluorine bearing compounds.
Decomposition: Decomposition when burned, this material will release
tetrafluoroethylene carbonyl fluoride, perfluorocarbon, olefins, and possibly some
hydrogen fluoride.
Incompatible Material: In service, avoid incompatible media such as molten
alkali metals, fluorine, and certain fluorine bearing compounds.
Hazardous Polymerization: May occur


Section 11 鈥? Toxicological Information
Acute Toxicity:
A) General Product Information: As a general practice, individuals working with
or handling this product should not smoke.

B) Component Analysis:

Component Carcinogenicity: None known

Irritancy of the Product:
Acute Inhalation:
Skin Contact:


Section 12 鈥? Ecological Information
No ecological concerns can be identified with this product

Section 13 鈥? Disposal Considerations
US EPA Waste Number and Descriptions:
A) General Product Information: This product is not expected to be a
characteristic waste under RCRA.
B) Component Waste Numbers: No EPA Numbers are applicable for this
product鈥檚 components.



4
www.dxseal.com 330-856-4635
Material Safety Data Sheet
Style DX Alltra 480 PTFE Sheet
DXSeal, Inc.
Revised: November 5, 2006


Disposal Instructions: This product can be disposed of in a normal manner.
Local regulations may apply.

Section 14 鈥? Transportation Information
US DOT Regulations:
Primary Hazard Class / Division: This product has no classification.
Other Shipping Information: Product should remain in a proper container
during transportation.

Section 15 鈥? Regulatory Information
US Federal Regulations:
A) General Product Information: No additional information available
B) Component Analysis: None of the components of this product are listed
under SARA Section 302 (40 CFR 355 Appendix A), SARA Section 313 (40 CFR
372.65) and/or CERCLA (40 CFR 302.4).


State Regulations:
A) General Product Information: No Additional Information available.
B) Component Analysis 鈥? State: The Following Components appear on one or
more of the state hazardous substance list:

Component CAS# CA FL MA MN NJ PA


Other Regulations:
A) General Product Information: No additional Information available.
B) TSCA Status: This Product and its components are listed on the TSCA 8(b)
inventory. None of the components listed on the TSCA Export Notification
12(b) list.
C) Component Analysis - Inventory

Component CAS# TSCA DSL ELNCS


D) Canada Workplace Hazardous Materials Information System (WHMIS)
This product has been classified in accordance with the hazard criteria
of the Controlled Products Regulations and the MSDS contains all of the
information required by the Controlled Products Regulations.


5
www.dxseal.com 330-856-4635

ALL Chemical Analysis PAGES IN THIS GROUP
NAMECAS
draglamsalt_com_Landscapers_Choice.asp N/A
7791-18-6.asp 7791-18-6 10035-04-8 7447-40-7 7647-14-5 7732-18-5
7440-44-0.asp 7440-44-0 9002-84-0
drewscientific_com_A_MSDS3SS.asp N/A
7664-93-9.asp 7664-93-9
drug_che_kuas_edu_tw_msds0228.asp N/A
124-38-9.asp 124-38-9
124-38-9.asp 124-38-9
124-38-9.asp 124-38-9
9003-53-6.asp 9003-53-6 109-66-0 3194-55-6
74-98-6.asp 74-98-6 106-97-8 100-41-4 1330-20-7 67-64-1 14807-96-6 471-34-1 13463-67-7 1333-86-4
1330-20-7.asp 1330-20-7 108-88-3 95-63-6 100-42-5 71-43-2 100-41-4 110-54-3 110-82-7 91-20-3 1634-04-4 637-92-3 994-05-8 108-20-3
7085-85-0.asp 7085-85-0 9011-14-7 123-31-9
111-77-3.asp 111-77-3 84-74-2 7664-41-7
14808-60-7.asp 14808-60-7 1309-48-4 7783-20-2
2551-62-4.asp 2551-62-4
dsc_dixie_edu_000257.asp N/A
dtsc_ca_gov_HWM_FS_Perchlorate_7061.asp N/A
8032-32-4.asp 8032-32-4
duallite_com_mflagelmsds.asp N/A
7439-92-1.asp 7439-92-1 7664-93-9
duallite_com_mfncmsds.asp N/A
duallite_com_mfplmsds.asp N/A
7440-66-6.asp 7440-66-6 7429-90-5 7440-36-0 7439-89-6 7440-44-0 7440-47-3 7439-96-5 8049-19-2 7439-98-7 7440-02-0 7440-21-3 7704-34-9
ductworks_com_FosterAfterFlood.asp N/A
durasystems_com_Enzyme_Magic_Septic_Tank_Treatment_MSDS.asp N/A
5989-27-5.asp 5989-27-5 25265-71-8 25168-05-0 9036-19-5
109-99-9.asp 109-99-9 78-93-3 108-94-1
14808-60-7.asp 14808-60-7 7704-34-9
5700-49-2.asp 5700-49-2
durvet_com_252_MSDS.asp N/A
100-51-6.asp 100-51-6 50-00-0 1405-41-0 8012-95-1 1338-43-8 102-71-6
durvet_com_381_MSDS.asp N/A
dustbane_ca_Aqua_Scrub_en.asp N/A
9002-84-0.asp 9002-84-0
9025-57-4.asp 9025-57-4
9025-57-4.asp 9025-57-4
208064-14-4.asp 208064-14-4 25068-38-6
d_umn_edu_UMD604_Procedure.asp N/A
6834-92-0.asp 6834-92-0 9016-45-9 5197-80-8 1310-73-2 64-02-8
0123-86-4.asp 0123-86-4 13463-67-7
25068-38-6.asp 25068-38-6 25154-52-3 68410-23-1 111-40-0 80-05-7
ebarnett_com_000232.asp N/A
64742-88-7.asp 64742-88-7 1317-65-3 107-21-1 27138-31-4 7664-41-7 9036-19-5
ebarnett_com_001313.asp N/A
ebarnett_com_002358.asp N/A
7775-14-6.asp 7775-14-6 7681-57-4
108-78-1.asp 108-78-1 127-09-3 64-19-7 7732-18-5
7446-08-4.asp 7446-08-4 7440-50-8 7786-81-4
7696-12-0.asp 7696-12-0 51-03-6 74-98-6


HBCChem,Inc

Chemical Information Net chemcas.orgCopyright Reserved

Trading Lead

Leputech HPLC Laboratory