Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

298-93-1

File Name: 298-93-1.asp

                           Material Safety Data Sheet (MSDS)
CellQuanti-MTT Cell Viability Assay Kits
Revision Number: 1.0 Last updated 04/10/2004



Product and Company Identification Physical and Chemical Properties
Component Name: CellQuanti-MTT Reagent Solid
Form:
Catalog Number: CQMT-500, CQMT-01K Odorless
Odor:
Manufacturer/Supplier: BioAssay Systems Yellowish
Color:
3423 Investment Blvd, Suite 11 Soluble
Solubility in Water:
Hayward, CA 94545. USA Not determined
Specific Gravity:
Fax: 510-739-0535 Not applicable
Flash Point:
Email: info@bioassaysys.com 0%
Organic Solvents:
http://www.bioassaysys.com 0%
Water:
100%
Solids Content:
Composition / Information on Ingredients
3-(4,5-Dimethyl-2-thiazolyl)-2,5-diphenyltetrazolium bromide (CAS Stability and Reactivity
Number: 298-93-1) Thermal Decomposition: no decomposition if used according to
specifications.
Hazards Identification
Dangerous Products of Decomposition: nitrogen and sulfur
Emergency Overview: Avoid contact and inhalation. To our
oxides.
knowledge, the hazards of this material have not been thoroughly
Dangerous Reactions: reacts with strong acids and oxidizing
investigated. We recommend handling all chemicals with caution.
agents.
Potential Health Effects
Toxicological Information
Toxic
Inhalation:
Not determined.
Toxicity:
Toxic
Ingestion:
Not thoroughly investigated.
Health Hazards:
Potentially irritating effect
Skin:
The complete properties have not been
Potential Hazards:
Irritating effect
Eyes:
investigated. Irritating effect on the
Toxic
Chronic Exposures:
skin. Irritating effects on the eye.
Not determined
Target Organs:
Ecological Information
Potentially harmful. Avoid prolonged or repeated exposure. Wash
Do not allow product to reach ground water, water course, or
thoroughly after handling. If eye or skin contact occurs, immediately
sewage system.
wash affected area with soap and copious amounts of water for at
least 15 minutes. Assure adequate flushing by separating the Disposal Considerations
eyelids with fingers. Call a physician to seek medical advice. If Must not be disposed of together with household garbage. Do not
swallowed, wash out mouth with water provided person is allow product to reach sewage system. Consult local, state or
conscious and call a physician to seek medical advice. If inhaled, national regulations for proper disposal.
move individual to fresh air and call a physician to seek medical
Transport Information
advice.
Not determined
Hazard Class:
Fire Fighting Measures Not determined
Identification Number:
Extinguishing media: water spray, carbon dioxide, dry chemical Not classified
Packing Group:
powder or appropriate foam. Not determined
Proper Shipping Name (Technical Name):
Special firefighting procedures: wear self-contained breathing
Regulations
apparatus and protective clothing to prevent contact with skin and
Not listed
US Toxic Substances Control Act (TSCA):
eyes.
Not applicable
US Other:
Unusual fire and explosion hazards: emits toxic fumes under fire
Not identified
EEC EINICS Number:
conditions.
None identified
Other Country Regulations:
Accidental Release Measures Not determined
EEC Risk Statements:
Use appropriate protective equipment and methods to clean up
Other Information
spilled substances promptly. Absorb spill onto an appropriate
This material is sold for research purposes only. It is not intended
material. Collect and dispose of all waste in accordance with
for food, drug, household, agricultural or cosmetic use. Its use
applicable laws.
must be supervised by a technically qualified individual
Handling and Storage experienced in handling potentially hazardous chemicals. The
Keep receptacles tightly sealed. Protect material from long-term above information is believed to be correct but does not purport to
exposure to light; may be exposed to light for short periods of time. be all inclusive and shall be used only as a guide. Users should
Store at -20 掳C. make independent decisions regarding completeness of the
information based on all sources available. This shall not constitute
Exposure Controls / Personal Protection
a guarantee for any specific product features and shall not
Keep away from foodstuffs and beverages. Wash hands before and
establish a legally valid contractual relationship. BioAssay Systems
after the work. Wear appropriate gloves, protective clothing and
shall not be held liable for any damage resulting from handling or
eyewear and follow safe laboratory practices.
from contact with the above product.
ACGIH/OSHA Permissible Exposure Limit Data
Not determined




CQMT-MSDS.pdf www.i-dna.biz Page 1 of 2
Material Safety Data Sheet (MSDS)
CellQuanti-MTT Cell Viability Assay Kits
Revision Number: 1.0 Last updated 04/10/2004



Product and Company Identification Physical and Chemical Properties
Component Name: Solubilization Buffer Liquid
Form:
Catalog Number: CQMT-500, CQMT-01K Characteristic
Odor:
Manufacturer/Supplier: BioAssay Systems Colorless
Color:
3423 Investment Blvd, Suite 11 Fully miscible
Solubility in Water:
Hayward, CA 94545. USA Not determined
Specific Gravity:
Fax: 510-739-0535 Not applicable
Flash Point:
Email: info@bioassaysys.com 0%
Organic Solvents:
http://www.bioassaysys.com 60-90%
Water:
2-40%
Solids Content:
Composition / Information on Ingredients
Sodium dodecanesulfonate (CAS Number: 13419-61-9):2-40% Stability and Reactivity
hydrochloric acid: 2-200 mM. Thermal Decomposition: no decomposition if used according to
specifications.
Hazards Identification
Dangerous Products of Decomposition: carbon monoxide and
Emergency Overview: Avoid contact and inhalation. To our
carbon dioxide.
knowledge, the hazards of this material have not been thoroughly
Dangerous Reactions: reacts with bases.
investigated. We recommend handling all chemicals with caution.
Toxicological Information
Potential Health Effects Not determined.
Toxicity:
Toxic by inhalation
Inhalation: Not thoroughly investigated.
Health Hazards:
Harmful if swallowed
Ingestion: The complete properties have not been
Potential Hazards:
Harmful if absorbed through the skin
Skin: investigated. Prolonged exposure may
Causes eyes irritation
Eyes: cause nausea, headache and vomiting.
Toxic
Chronic Exposures:
Ecological Information
Nerves, kidneys, cardiovascular
Target Organs:
Do not allow product to reach ground water, water course, or
system, GI system
sewage system.
Potentially harmful. Avoid prolonged or repeated exposure. Wash
Disposal Considerations
thoroughly after handling. If eye or skin contact occurs, immediately
Must not be disposed of together with household garbage. Do not
wash affected area with soap and copious amounts of water for at
allow product to reach sewage system. Consult local, state or
least 15 minutes. Assure adequate flushing by separating the
national regulations for proper disposal.
eyelids with fingers. Call a physician to seek medical advice. If
swallowed, wash out mouth with water provided person is Transport Information
conscious and call a physician to seek medical advice. If inhaled, Not determined
Hazard Class:
move individual to fresh air and call a physician to seek medical Not determined
Identification Number:
advice. Not classified
Packing Group:
Not determined
Proper Shipping Name (Technical Name):
Fire Fighting Measures
Extinguishing media: water spray, carbon dioxide, dry chemical Regulations
powder or appropriate foam. Not listed
US Toxic Substances Control Act (TSCA):
Special firefighting procedures: wear self-contained breathing Not applicable
US Other:
apparatus and protective clothing to prevent contact with skin and Not identified
EEC EINICS Number:
eyes. None identified
Other Country Regulations:
Unusual fire and explosion hazards: emits toxic fumes under fire Not determined
EEC Risk Statements:
conditions.
Other Information
Accidental Release Measures This material is sold for research purposes only. It is not intended
Use appropriate protective equipment and methods to clean up for food, drug, household, agricultural or cosmetic use. Its use
spilled substances promptly. Absorb spill onto an appropriate must be supervised by a technically qualified individual
material. Collect and dispose of all waste in accordance with experienced in handling potentially hazardous chemicals. The
applicable laws. above information is believed to be correct but does not purport to
be all inclusive and shall be used only as a guide. Users should
Handling and Storage
make independent decisions regarding completeness of the
Keep receptacles tightly sealed. Can be stored at room
information based on all sources available. This shall not constitute
temperature.
a guarantee for any specific product features and shall not
Exposure Controls / Personal Protection establish a legally valid contractual relationship. BioAssay Systems
Keep away from foodstuffs and beverages. Wash hands before and shall not be held liable for any damage resulting from handling or
after the work. Wear appropriate gloves, protective clothing and from contact with the above product.
eyewear and follow safe laboratory practices.
ACGIH/OSHA Permissible Exposure Limit Data
Not determined




CQMT-MSDS.pdf www.i-dna.biz Page 2 of 2

ALL Chemical Analysis PAGES IN THIS GROUP
NAMECAS
hyne_com_au_07_SawdustNonTreatedHwd.asp N/A
hzlhx_com_msdslhx.asp N/A
298-93-1.asp 298-93-1
ifront_sekisui_co_jp_ebbls.asp N/A
2002-01-1.asp 2002-01-1
78-11-5.asp 78-11-5 118-96-7 13424-46-9 7758-97-6
icorecomposites_com_EGBLCMSDS.asp N/A
idccorp_com_roxul_minerwool.asp N/A
idimn_com_SilverShield_MSDS.asp N/A
ifa_hawaii_edu_Aluminum_Alloys.asp N/A
ifa_hawaii_edu_Chevron_Supreme_Motor_Oil_SAE_30.asp N/A
9002-84-0.asp 9002-84-0 50-00-0
5989-27-5.asp 5989-27-5
7440-50-8.asp 7440-50-8 7440-31-5 7440-48-4 7440-66-6 7440-02-0
65997-17-3.asp 65997-17-3 25104-55-6
64742-93-4.asp 64742-93-4 7704-34-9 7783-06-4
56-81-5.asp 56-81-5 111-46-6 25322-68-3 26172-55-4 102-71-6
56-40-6.asp 56-40-6 107-21-1 57-55-6 56-81-5 616-45-5 68072-38-8 9014-85-1 2634-33-5 214559-61-2
123-31-9.asp 123-31-9 22-40-4
79-10-7.asp 79-10-7 061-00-8 22-35-5 39-45-6
64-18-6.asp 64-18-6 001-00-0 23-26-4
6153-56-6.asp 6153-56-6 006-00-8
64742-94-5.asp 64742-94-5
ilrc_ucf_edu_MSDS_00000189.asp N/A
64742-88-7.asp 64742-88-7 74-98-6 64741-88-4 64742-52-5 64742-54-7 64741-96-4 471-34-1 61789-86-4 75-28-5 64742-47-8 64742-95-6 25551-13-7 95-63-6
111-76-2.asp 111-76-2 8052-41-3
images_cableorganizer_com_firebarrierMSDS.asp N/A
50800-85-6.asp 50800-85-6 7647-01-0 7732-18-5
7732-18-5.asp 7732-18-5 01333-86-4 57-55-6 100-42-5
11-01-0.asp 11-01-0
11-01-0.asp 11-01-0 25535-16-4
64742-47-8.asp 64742-47-8 66402-68-4 14808-60-7 14464-46-1 64741-44-2 68855-54-9 67-63-0 57-55-6 7732-18-5 8004-87-3
5989-27-5.asp 5989-27-5
64742-47-8.asp 64742-47-8 66402-68-4 14808-60-7 14464-46-1 64741-44-2 68855-54-9 67-63-0 57-55-6 7732-18-5 8004-87-3
5989-27-5.asp 5989-27-5
imscompany_com_sp_purgex.asp N/A
7440-02-0.asp 7440-02-0 7782-42-5
10101-97-0.asp 10101-97-0
598-63-0.asp 598-63-0 13099-33-7 10102-49-5 7631-86-9 7787-59-9
7440-02-0.asp 7440-02-0 7429-90-5
52315-07-8.asp 52315-07-8
7782-44-7.asp 7782-44-7 74-82-8 7783-06-4 630-08-0 7727-37-9
25068-38-6.asp 25068-38-6 25085-99-8 13463-67-7 14807-96-6 68515-49-1 26761-40-0
25068-38-6.asp 25068-38-6 14808-60-7 13463-67-7 78-93-3 123-86-4 1330-20-7 67-63-0
110-54-3.asp 110-54-3 63148-62-9 75-28-5 74-98-6
1314-13-2.asp 1314-13-2 68476-85-7
9002-88-4.asp 9002-88-4
7727-37-9.asp 7727-37-9
infab_org_NewMSDS.asp N/A
9002-88-4.asp 9002-88-4 25087-34-7 25213-02-9


HBCChem,Inc

Chemical Information Net chemcas.orgCopyright Reserved

Trading Lead

Leputech HPLC Laboratory