NuGenTec
NuKut SO 15 P Page 1 of 8
PRD Number: MGD215 June 4, 2007
MATERIAL SAFETY DATA SHEET
1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
Product Identification
----------------------
Product Name: NuKut SO 15 P Product Number: MGD215
Synonyms: Soluble oil - heavy duty - NO Chlorine, NO Sulfur
CAS Number: Blend
Company Identification
----------------------
NuGeneration Technologies, LLC
100 Professional Center Drive Suite 101, Rohnert Park, CA 94928 USA
(707) 820-4080 (For product information)
1-800-424-9300 or 1-202-483-7616 (CHEMTREC: For emergencies)
SPECIAL NOTES:
This product contains <0.01% water.
2. COMPOSITION/INFORMATION ON INGREDIENTS
100.0% NuKut SO 15 P
CONTAINING:
HAZARDOUS AND/OR REGULATED COMPONENTS
Chemical Name Amount CAS Number
------------- -------- ----------
78.0 % 64742-52-5
SEVERELY HYDROTREATED HEAVY NAPTHENIC DISTILLATE
BIOCIDE 2.0 % 4719-04-4
NON-HAZARDOUS COMPONENTS
Chemical Name Amount CAS Number
------------- -------- ----------
EMULSIFER 15.0 % tradesecret
PROPRIETARY LUBRICANT PACKAGE 5.0 % TRADESECRET
Note: non-hazardous components are listed for informational purposes only.
(See Section 8 for exposure guidelines)
(See Section 15 for regulatory information)
COMPOSITION COMMENT:
California Prop 65: This product does not contain any ingredients which
are know to the state of california to cause cancer, birth defects, or
other reproductive harm.
HAZARDS DISCLOSURE
This product contains hazardous materials as defined by the OSHA Hazard
Communication Standard 29 CFR 1910.1200.
As defined under Sara 311 and 312, this product contains no known
hazardous materials.
MISCELLANEOUS:
This product contains Mineral oil.
NuGenTec
NuKut SO 15 P Page 2 of 8
PRD Number: MGD215 June 4, 2007
3. HAZARDS IDENTIFICATION
***************** EMERGENCY OVERVIEW *****************
* *
* Low hazard for usual industrial or commercial *
* handling. Keep out of waterways. In case of fire, *
* hazardous vapors may become an inhalation hazard. *
* Avoid breathing mist. *
* *
**********************************************************
HMIS Rating - Health: 1
Flammability: 1
Reactivity: 0
Personal Protection Index: C
NFPA Rating - Health: 1
Flammability: 1
Reactivity: 0
Special Hazard: None
NFPA/HMIS Definitions: (0-Least, 1-Slight, 2-Moderate, 3-High,
4-Extreme). These values are obtained using the guidelines or published
evaluations prepared by the National Fire Protection Association (NFPA) or
the National Paint and Coating Association (for HMIS ratings).
POTENTIAL HEALTH EFFECTS
EYE:
May cause slight irritation.
SKIN:
Not expected to be a skin irritant.
INHALATION:
No hazards expected in normal industrial use at room temperature. Vapors
and/or aerosols may be irritating to eyes and respiratory tract.
INGESTION:
Essentially non-toxic. Ingestion is not considered a potential route of
exposure. If ingested may cause a laxative effect.
SIGNS AND SYMPTOMS OF EXPOSURE:
If exposed areas are flushed promptly and thoroughly with SOAP & water,
there should be little or no harm. Overexposure may lead to skin
irritation or inflammation.
CHRONIC EFFECTS:
Prolonged and/or repeated contact may produce mild to moderate skin
irritation or inflammation.
REPRODUCTIVE HAZARDS:
No reproductive hazards.
CARCINOGENICITY INFORMATION:
This product has been shown not to be carcinogenic, it is not included as
a carcinogen by IARC, OSHA, NTP, or EPA.
NuGenTec
NuKut SO 15 P Page 3 of 8
PRD Number: MGD215 June 4, 2007
TARGET ORGAN:
Skin, mucus membranes and lungs.
MEDICAL CONDITIONS AGRAVATED BY EXPOSURE:
Personnel with pre-existing skin disorders and chronic respiratory
diseases should avoid contact with this product.
MISCELLANEOUS:
Solutions extremely slippery when spilled. Poses little or no immediate
hazard.
4. FIRST AID MEASURES
EYE CONTACT FIRST AID:
Hold eyelids apart and flush eyes with plenty of water for at least 15
minutes. Get medical attention if irritation develops or persists.
SKIN CONTACT FIRST AID:
Immediately wash skin with plenty of soap and water while removing
contaminated clothing and shoes. Get medical attention if irritation
develops or persists.
INHALATION FIRST AID:
Although this product is not known to cause respiratory problems, if
breathing is difficult, remove to fresh air and provide oxygen. Get
medical attention if cough or other symptoms develop.
Remove from area of exposure. Seek immediate medical attention if
respiratory irritation or distress continues.
INGESTION FIRST AID:
Ingestion is not considered a potential route of exposure. May act as a
laxative. Give water or milk and induce vomiting. Get medical attention
immediately.
STATEMENT OF PRACTICAL TREATMENT:
Always have plenty of water available for first aid.
NOTES TO PHYSICIAN:
Treat patient symptomatically.
5. FIRE FIGHTING MEASURES
FLAMMABLE PROPERTIES
COC Flash Point: 165.6 C (330.1 F)
Autoignition Temperature: 329.4 C (624.9 F)
FLAMMABLE LIMITS IN AIR
LEL: 1.0 AP %
UEL: 7.0 AP %
FLAMMABLE PROPERTIES:
This product is considered Slightly Combustible! OSHA/NFPA Class-IIIB
Combustible Liquid.
NuGenTec
NuKut SO 15 P Page 4 of 8
PRD Number: MGD215 June 4, 2007
EXTINGUISHING MEDIA:
Carbon dioxide, foam, or dry powder.
FIRE & EXPLOSION HAZARDS:
Can release vapors that form explosive mixtures at temperatures at or
above the flashpoint.
FIRE FIGHTING INSTRUCTIONS:
Contain runoff water. Contaminated extinguishing water must be disposed
of in accordance with applicable regulations. As in any fire, wear
self-contained breathing apparatus pressure-demand MSHA/NIOSH (approved or
equivalent) and full protective gear. Avoid breathing smoke, fumes, and
decomposition products. Evacuate non-emergency personnel to a safe area.
Water runoff can cause environmental damage. Comply with all laws and
regulations.
COMBUSTION PRODUCTS:
Dense smoke may be generated while burning. Carbon Monoxide, carbon
dioxide, and other oxides may be generated as products of combustion.
6. ACCIDENTAL RELEASE MEASURES
SAFEGUARDS (PERSONNEL):
Eliminate all sources of ignition - heat, sparks, flame, electricity,
impact and friction. Evacuate non-emergency personnel to a safe area.
Review Fire Fighting Measures and Handling (Personnel) Sections before
proceeding with clean-up. Wear appropriate personal protective equipment.
INITIAL CONTAINMENT:
Floor may become slippery. Contain spilled material. Absorb spills with
inert material. Wash area to prevent slipping. Treat or dispose of waste
material in accordance with all local, state/provincial, and national
requirements.
LARGE SPILLS PROCEDURE:
Forms smooth, slippery surfaces on floors, posing an accident risk. Clean
up spills immediately, observing precautions in Protective Equipment
section. Absorb spill with inert material (e g, dry sand or earth), then
place in a chemical waste container. After removal, flush contaminated
area thoroughly with soap and water. Dispose of in an approved sanitary
landfill. Treat or dispose of waste material in accordance with all
local, state/provincial, and national requirements. May be a regulated
waste. Materials should be recycled if possible.
SMALL SPILLS PROCEDURE:
Floor may become slippery. Absorb spills with inert material. Avoid
disposal into waste water treatment facilities. After cleaning spill with
absorbent material wash area with soap and water. Treat or dispose of
waste material in accordance with all local, state/provincial, and
national requirements.
7. HANDLING AND STORAGE
RECOMMENDED STORAGE TEMPERATURE
Minimum: 4.4 C (39.9 F)
Maximum: 48.9 C (120.0 F)
NuGenTec
NuKut SO 15 P Page 5 of 8
PRD Number: MGD215 June 4, 2007
SHELF LIFE: (in original, sealed containers)
>10 years @ 4.4 C
>3 years @ 48.9 C
HANDLING (PERSONNEL):
Avoid contact with eyes, skin, and clothing. Empty drums should be
completely drained (triple rinsed), properly bunged, and promptly returned
to a drum reconditioner, or properly disposed of. Wash hands thoroughly
after handling. Wash contaminated clothing before reuse.
HANDLING (PHYSICAL ASPECTS):
Eliminate all sources of ignition - heat, sparks, flame, electricity,
impact and friction. Keep container closed to avoid contamination. Avoid
contact with strong oxidizing agents. Avoid extreme temperatures.
STORAGE PRECAUTIONS:
Store in a cool dry place. Do not stack drums more than three pallets
high. Store in a tightly closed container.
MISCELLANEOUS:
Do not stack over three pallets high.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
ENGINEERING CONTROLS:
Good general ventilation should be sufficient to control airborne levels.
Facilities storing or utilizing this material should be equipped with an
eyewash facility and a safety shower.
EYE / FACE PROTECTION REQUIREMENTS:
When splashing of the material may occur, chemical goggles and a face
shield are recommended. This material does not have established exposure
limits. A NIOSH/MSHA approved air purifying respirator with an organic
vapor cartridge or canister may be permissible under certain circumstances
where airborne concentrations are expected to exceed exposure limits.
SKIN PROTECTION REQUIREMENTS:
Wear protective gloves to minimize skin contact. Nitrile rubber and PVC
are suitable protective materials; Neoprene is recommended. Wash hands
thoroughly after handling.
RESPIRATORY PROTECTION REQUIREMENTS:
Under normal use conditions, with adequate ventilation, no special
handling equipment is required. When there is potential for airborne
exposures in excess of applicable limits, wear NIOSH/MSHA approved
respiratory protection.
MISCELLANEOUS:
Where an apron and protective clothing.
EXPOSURE GUIDELINES:
Severely hydrotreated heavy naphthenic distillate
OSHA PEL: 5 mg/m^3
NuGenTec
NuKut SO 15 P Page 6 of 8
PRD Number: MGD215 June 4, 2007
9. PHYSICAL AND CHEMICAL PROPERTIES
FORM ...............................: Liquid
COLOR ..............................: light Brown
ODOR ...............................: hydrocarbon lube oil odor
BOILING POINT ......................: > 500 F
VAPOR PRESSURE .....................: <0.1 mm Hg @ 70 F
VAPOR DENSITY ......................: >10 (Air = 1)
SOLUBILITY IN WATER ................: Emulsifiable
SPECIFIC GRAVITY ...................: 0.91 (Water = 1)
BULK DENSITY .......................: 7.6
MELTING/FREEZING POINT .............: -20 F
PH .................................: N/A
% VOLATILES ........................: Zero %
VISCOSITY ..........................: ~100 SUS @ 100F
EVAPORATION RATE ...................: <1 (EE=1)
VOLATILE ORGANIC COMPOUNDS (VOC) ...: Nil
PH (5% B.V.) .......................: 9.5
10. STABILITY AND REACTIVITY
STABILITY:
Stable.
POLYMERIZATION:
Hazardous polymerization will not occur.
INCOMPATIBILITY WITH OTHER MATERIALS:
Avoid contact with strong oxidizing agents.
DECOMPOSITION:
Decomposition may produce fumes, smoke, oxides of carbon and
hydrocarbons. Decomposition will not occur if handled and stored
properly.
CONDITIONS TO AVOID:
This material is safe under normal storage and handling conditions.
11. TOXICOLOGICAL INFORMATION
EYE EFFECTS:
This product is minimally irritating to the eyes upon direct contact.
SKIN EFFECTS:
This product is not expected to cause any skin irritation upon direct
single or repeated contact.
ACUTE ORAL EFFECTS:
No know hazards in normal industrial use.
ACUTE INHALATION EFFECTS:
This product has a low vapor pressure and is not expected to present an
inhalation hazard at ambient conditions. Caution should be taken to
prevent aerozolization or misting of this product. The permissible
exposure limit (PEL) and Threshold Limit value (TLV) for this product as
oil mist is 5 mg/m3. Exposures below 5 mg/m3 appear to be without
NuGenTec
NuKut SO 15 P Page 7 of 8
PRD Number: MGD215 June 4, 2007
significant health risk. The short term exposure limit for this product
as an oil mist is 10 mg/m3.
REPRODUCTION AND BIRTH EFFECTS:
There are no known or reported effects on reproductive function or fetal
development.
CHRONIC EFFECTS /:
There are no know or reported effects from repeated exposure.
Severely Hydrotreated Heavy Napthenic Distillate
Test Code: Oral LD50
Species: Rat
Results: > 5,000 mg/kg
12. ECOLOGICAL INFORMATION
No information available.
13. DISPOSAL CONSIDERATIONS
WASTE DISPOSAL:
Uncleaned empty containers should be disposed of in the same manner as
the contents. Recycling of this material is recommended if possible,
otherwise incinerate or bury in an approved sanitary landfill. Treat or
dispose of waste material in accordance with all local, state/provincial,
and national requirements. For additional waste disposal information
contact your local NuGenTec representative at (888) 99-NuGen or (209)
234-5930.
CONTAMINATED MATERIALS:
Wash contaminated clothing before reuse.
CONTAINER DISPOSAL:
Clean out containers prior to disposal. Misuse of containers may be
hazardous. Empty containers can be dangerous if used to store toxic,
flammable, or reactive materials. Cutting or welding containers might
cause fire, explosion, or toxic fumes from residues. Do not pressurize
or expose to open flames or heat. Keep container closed and drum bungs
in place.
MISCELLANEOUS:
Maximize product use for reuse or recycling. Conditions may cause this
product to become 'hazardous waste' as defined by state or federal laws.
NuGenTec
NuKut SO 15 P Page 8 of 8
PRD Number: MGD215 June 4, 2007
14. TRANSPORTATION INFORMATION
PRODUCT LABEL .............: NuKut SO 15 P
D.O.T. SHIPPING NAME ......: Non-Regulated Material
TECHNICAL SHIPPING NAME ...: Class 55
D.O.T. HAZARD CLASS .......: Non-Hazardous
UN NUMBER .................: N/A
PRODUCT RQ (LBS) ..........: N/A
D.O.T. LABEL ..............: NOBIN Non-Hazardous
D.O.T. PLACARD ............: N/A
BULK CLASS ................: N/A
PACKAGE CLASS .............: 55
15. REGULATORY INFORMATION
EEC Symbols and Indications of Danger:
None
WHMIS Hazard Symbols:
None
MISCELLANEOUS INFORMATION:
This material or all of its components are listed on the Inventory of
Existing Chemical Substances under the Toxic Substance Control Act
(TSCA). This material or all of its components are listed on the
Canadian Domestic Substances List (DSL). This material or all of its
components are listed (or considered as having been notified) on the
European Inventory of Existing Chemical Substances (EINECS).
16. OTHER INFORMATION
PREPARED BY .......: Donato Polignone
APPROVAL DATE .....: June 4, 2007
SUPERCEDES DATE ...: September 3, 2002
PRD NUMBER ........: MGD215 (Official Copy)
ADDITIONAL INFORMATION:
The data in this Material Safety Data Sheet relates only to the specific
material designated herein. It does not relate to use in combination
with any other material or in any process.
**********************************************************************
This information is furnished without warranty, expressed or implied,
except that it is accurate to the best knowledge of NuGeneration
Technologies, LLC. The data on this sheet are related only to the
specific material designated herein. NuGeneration Technologies, LLC
assumes no legal responsibility for use or reliance upon these data.
**********************************************************************
END OF MSDS
**********************************************************************
|