MATERIAL SAFETY DATA SHEET 03/28/2006
For Coatings, Resins and Related Materials
===============================================================================
-------------------------------------------------------------------------------
SECTION I - PRODUCT IDENTIFICATION
-------------------------------------------------------------------------------
Manufacturer: Crawford Laboratories, Inc. Information Phone: 773-376-7132
4165 South Emerald Avenue Emergency Phone: 800-424-9300
-----------------------------------
Chicago IL 60609 ! Hazard Ratings: Health - 3
Product Class: MCU ! none -> extreme Fire - 3
Trade Name : SYSTEM 7000 LIGHT-NEUTRAL ! 0 ---> 4 Reactivity - 0
Product Code : R0-142 !
C.A.S. Number: see below !
===============================================================================
-------------------------------------------------------------------------------
SECTION II - HAZARDOUS INGREDIENTS
-------------------------------------------------------------------------------
Weight --- Exposure Limits ---- VP
Ingredients CAS # % ACGIH/TLV OSHA/PEL mm HG
___________ ____________ _____________________________________
* XYLENE 1330-20-7 20-50 100 ppm 100 21.
S.T.E.L.= 150 150
The above item contains approx. 15 % Ethylbenzene,CAS# 100-41-4
The International Agency for Research on Cancer (IARC) has
evaluated ethylbenzene and classified it as a possible human
carcinogen (group 2B) based on sufficient evidance for carcinogy
in experimantal animals, but inadequate evidance for cancer in
exposed humans.
AROMATIC HYDROCARBON 64742-95-6 5-20 50 ppm 50 9.
PM ACETATE 108-65-6 1-5 Undetermined 4.
* see below 101-68-8 5-20 .005 ppm .02
ABOVE ITEM IS 4,4'-Diphenylmethane-diisocyanate
PHYSICIAL HAZZARDS : UNSTABLE
HEALTH HAZZARDS : Irritant (eyes, skin, respiratory passages,
skin sensitizer). Inhalation (TLV). Based on MDI - harmful
(respiratory sensitizer, lung injury)
MODIFIED MDI 5-20 Undetermined
MANUFACTURER OF ABOVE ITEM FURNISHES NO C.A.S. #
OR T.L.V.
* SECTION 313 SUPPLIER NOTIFICATION
This ingredient is subject to the reporting requirements
of section 313 of the Emergency Planning and Community
Right-To-Know Act of 1986 and of 40 CFR 372.
WARNING - DO NOT SPRAY APPLY THIS PRODUCT
===============================================================================
-------------------------------------------------------------------------------
SECTION III - PHYSICAL DATA
-------------------------------------------------------------------------------
Boiling Range: 243 - 484 Deg. F Vapor Density: Heavier than Air.
Evap. Rate: 0.56 x n-Butyl Acetate Liquid Density: Heavier than Water.
Volatiles volume: 47.1 % Wgt per gallon: 9.09 Pounds.
Appearance: NEUTRAL V.O.C.: 413 gpl
Crawford Laboratories, Inc.
Material Safety Data Sheet for: R0-142
Page 1
R0-142.TXT
===============================================================================
-------------------------------------------------------------------------------
SECTION IV - FIRE AND EXPLOSION HAZARD DATA
-------------------------------------------------------------------------------
Flammability Class: Flash Point: 93F SETA LEL : 1.1 %
-EXTINGUISHING MEDIA:
FOAM, CO2, OR DRY CHEMICAL
IF WATER IS USED, USE VERY LARGE QUANTITIES. THE REACTION
BETWEEN WATER AND HOT ISOCYANATE MAY BE VIGOROUS.
-SPECIAL FIREFIGHTING PROCEDURES:
WATER MAY BE USED TO KEEP EXPOSED CONTAINERS COOL, AND TO KEEP
FLAMMABLE STRUCTURES WET
DO NOT ENTER FIRE AREA WITHOUT PROPER PROTECTION BECAUSE
HAZARDOUS DECOMPOSITION PRODUCTS MAY BE PRESENT. (SEE VI)
-UNUSUAL FIRE & EXPLOSION HAZARDS:
WATER PRESSURE MAY SPREAD A FLAMMABLE LIQUID FIRE.
SEALED CONTAINERS MAY EXPLODE IF OVERHEATED.
DO NOT RESEAL CONTAMINATED CONTAINERS AS PRESSURE BUILDUP
MAY RUPTURE THEM.
===============================================================================
-------------------------------------------------------------------------------
SECTION V - HEALTH HAZARD DATA
-------------------------------------------------------------------------------
-PERMISSIBLE EXPOSURE LEVEL:
IF PEL'S ARE KNOWN, THEY ARE LISTED IN SECT. II
W A R N I N G CARE MUST BE TAKEN NOT TO EXCEED THE EXPOSURE
LIMIT FOR THE LOWEST TLV SHOWN IN SECTION II. WHEN IN DOUBT,
WEAR AN APPROVED RESPIRATOR AND ORDER AIR SAMPLING TESTS.
(SEE SECTION VIII)
-EFFECTS OF OVEREXPOSURE:
OVEREXPOSURE MAY PRODUCE VARIOUS EFFECTS, INCLUDING:
1-ACUTE TOXICITY, RESULTING IN HEADACHE, DIZZINESS, NAUSEA, AND
LOSS OF CONSCIOUSNESS.
2-SEVERE EYE IRRITATION POSSIBLY RESULTING IN PERMANENT DAMAGE.
3-IRRITATED MUCOUS MEMBRANES.
4-VOMITING DUE TO INGESTION.
5-DEFATTING AND DRYING OF THE SKIN.
6-SENSITIZATION AFTER REPEATED CONTACT.
MDI vapors or mist at concentrations above the TLV can irritate
the mucous membranes in the respiratory tract causing runny nose
sore throat and reduced lung fuction. Exposure well above the
TLV may lead to bronchitis, bronchial spasm and pulmonary
edema. These effects are usually reversible.
THERE ARE REPORTS THAT CHRONIC OVEREXPOSURES MAY RESULT IN
PERMENANT DECREASES IN LUNG FUNCTION.
-FIRST AID:
--EYE CONTACT-FLUSH WITH PLENTY OF CLEAN LUKEWARM LOW PRESSURE
WATER FOR 15 MIN., OCCASIONALY LIFTING EYELIDS OPEN.
GET MEDICAL ATTENTION.
--INHALATION-REMOVE VICTIM TO FRESH AIR AND PROVIDE OXYGEN IF
BREATHING IS DIFFICULT. GIVE ARTIFICIAL RESPIRATION IF NOT
BREATHING. GET MEDICAL ATTENTION. KEEP VICTOM WARM AND
COMFORTABLE. NEVER GIVE AN UNCONSCIOUS PERSON LIQUIDS.
--INGESTION-IF SWALLOWED, CALL PHYSICIAN IMMEDIATELY. ONLY
INDUCE VOMITING ON INSTRUCTIONS OF PHYSICIAN. IF VOMITING
OCCURS SPONTANEOUSLY, KEEP HEAD BELOW HIPS TO PREVENT
(cont.)
Crawford Laboratories, Inc.
Page 2
R0-142.TXT
Material Safety Data Sheet for: R0-142
===============================================================================
-------------------------------------------------------------------------------
SECTION V - HEALTH HAZARD DATA (cont.)
-------------------------------------------------------------------------------
-FIRST AID: (cont.)
ASPIRATION OF LIQUID INTO THE LUNGS. NEVER GIVE ANYTHING BY
MOUTH TO UNCONSCIOUS PERSON.
--SKIN CONTACT-FLUSH WITH WATER WHILE REMOVING CONTAMINATED
CLOTHING AND SHOES. FOLLOW BY WASHING WITH SOAP AND WATER.
DO NOT REUSE CONTAMINATED CLOTHING OR SHOES. IF IRRITATION
PERSISTS, GET MEDICAL ATTENTION.
===============================================================================
-------------------------------------------------------------------------------
SECTION VI - REACTIVITY DATA
-------------------------------------------------------------------------------
STABLITY: [ ] Unstable [x] Stable
HAZARDOUS POLYMERIZATION: [ ] May occur [x] Will not occur
-INCOMPATABILITY:
MAY BE INCOMPATIBLE WITH OXIDIZING AGENTS AND STRONG ALKALIES.
THIS PRODUCT WITH ANY MATERIALS CONTAINING ACTIVE HYDROCARBONS
SUCH AN WATER, ALCOHOL, AMMONIA, AMINES, ALKALIES AND ACIDS.
SOME REACTIONS MAY BE VIOLENT.
-CONDITIONS TO AVOID:
AVOID HEAT, SPARKS, OPEN FLAMES, AND INCOMPATIBILITIES ABOVE
HIGH TEMPERATURE, STRONG OXIDIZING CONDITIONS, EXTENDED
CONTACT WITH AIR/OXYGEN.
-HAZARDOUS DECOMPOSITION PRODUCTS:
INCOMPLETE COMBUSTION FOR PRODUCTS LIKE THIS MAY GENERATE
HIGHLY POISONOUS CARBON MONOXIDE AND OTHER TOXIC GASES.
===============================================================================
-------------------------------------------------------------------------------
SECTION VII - SPILL OR LEAK PROCEDURES
-------------------------------------------------------------------------------
-STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
WARNING - FLAMMABLE. ELIMINATE ALL IGNITION SOURCES.
HANDLING EQUIPMENT MUST BE GROUNDED TO PREVENT SPARKING.
SOAK UP WITH AN ABSORBENT AND PLACE IN NON-LEAKING
CONTAINERS. SEAL TIGHTLY FOR PROPER DISPOSAL.
WEAR SKIN, EYE, AND RESPIRATORY PROTECTION DURING CLEANUP. SOAK
UP MATERIAL WITH ABSORBENT AND SHOVEL INTO A CHEMICAL WASTE
CONTAINER. COVER CONTAINER, BUT DO NOT SEAL, AND REMOVE FROM
WORK AREA. PREPARE A DECONTAMINATION SOLUTION OF 0.2-0.5%
LIQUID DETERGENT AND 3-8% CONCENTRATED AMMONIUM HYDROXIDE IN
WATER (5-10% SODIUM CARBONATE MAY BE SUBSTITUTED FOR THE
AMMONIUM HYDROXIDE). FOLLOW THE PRECAUTIONS ON THE SUPPLIER'S
MATERIAL SAFETY DATA SHEETS. ALL OPERATIONS SHOULD BE
PERFORMED BY TRAINED PERSONNEL FAMILIAR WITH THE HAZARDS OF THE
CHEMICALS USED. TREAT THE SPILL AREA WITH THE DECONTAMINATION
SOLUTION, USING ABOUT 10 PARTS OF SOLUTION FOR EACH PART OF THE
SPILL, AND ALLOW IT TO REACT FOR AT LEAST 10 MINUTES. CARBON
DIOXIDE WILL BE EVOLVED, LEAVING INSOLUBLE POLYUREAS. FOR
MAJOR SPILLS, CALL CHEMTREC (CHEMICAL TRANSPORTATION EMERGENCY
CENTER) AT 800-424-9300.
Crawford Laboratories, Inc.
Material Safety Data Sheet for: R0-142
===============================================================================
-------------------------------------------------------------------------------
Page 3
R0-142.TXT
SECTION VII - SPILL OR LEAK PROCEDURES (cont.)
-------------------------------------------------------------------------------
-WASTE DISPOSAL METHOD:
DISPOSAL MUST BE IN ACCORDANCE WITH CURRENT LOCAL, STATE AND
FEDERAL REGULATION. CONTACT AN APPROVED DISPOSAL FACILITY.
SLOWLY STIR THE ISOCYANATE WASTE INTO THE DECONTAMINATION
SOLUTION DESCRIBED ABOVE USING 10 PARTS OF THE SOLUTION
FOR EACH PART OF THE ISOCYANATE. LET STAND FOR 48 HOURS,
ALLOWING THE EVOLVED CARBON DIOXIDE TO VENT AWAY. NEUTRALIZE
THE WASTE. NEITHER THE SOLID NOR THE LIQUID PORTION IS A
HAZARDOUS WASTE UNDER RCRA, 40 CFR 261.
DRUMS MUST BE DECONTAMINATED IN PROPERLY VENTILATED AREAS BY
PERSONNEL PROTECTED FROM THE INHALATION OF ISOCYANATE VAPORS.
SPRAY OR POUR 5-15 LITERS OF DECONTAMINATING SOLUTION INTO THE
DRUM, MAKING SURE THE WALLS ARE WELL RINSED. LEAVE THE DRUM
SOAKING UNSEALED FOR 48 HOURS. POUR OUT THE DECONTAMINATING
SOLUTION AND TRIPLE RINSE THE EMPTY CONTAINER. PUNCTURE OR
OTHERWISE DESTROY THE RINSED CONTAINER BEFORE DISPOSAL.
===============================================================================
-------------------------------------------------------------------------------
SECTION VIII - SPECIAL PROTECTION INFORMATION:
-------------------------------------------------------------------------------
-RESPIRATORY PROTECTION:
PROPERLY FITTED NIOSH/MSHA APPROVED RESPIRATORS SHALL BE USED
DURING APPLICATION UNLESS AIR MONITORING DEMONSTRATES VAPOR/MIST
LEVELS ARE BELOW APPLICABLE LIMITS.
-VENTILATION:
EFFECTIVE ENGINEERING CONTROLS SHOULD BE USED WHENEVER POSSIBLE
-PROTECTIVE GLOVES:
USE RUBBER GLOVES
-EYE PROTECTION:
WEAR APPROVED SAFETY GOGGLES AND/OR FACE SHIELD.
-OTHER PROTECTIVE EQUIPMENT:
HAVE EYE BATH AND SAFETY SHOWER AVAILABLE.
===============================================================================
-------------------------------------------------------------------------------
SECTION IX - SPECIAL PRECAUTIONS
-------------------------------------------------------------------------------
-PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING:
TREAT AS A HAZARDOUS-FLAMMABLE MATERIAL.
KNOW APPLICABLE D.O.T REGULATIONS BEFORE ATTEMPTING TO
TRANSPORT THIS MATERIAL.
"WARNING: HOT ORGANIC CHEMICAL VAPORS OR MISTS ARE
SUSCEPTIBLE TO SUDDEN SPONTANEOUS COMBUSTION WHEN MIXED WITH
AIR. IGNITION MAY OCCUR AT TEMPERATURES BELOW THOSE PUBLISHED
IN THE LITERATURE AS "AUTOIGNITION" OR "IGNITION" TEMPERATURES.
IGNITION TEMPERATURES DECREASE WITH INCREASING VAPOR VOLUME AND
VAPOR/AIR CONTACT TIME AND ARE INFLUENCED BY PRESSURE CHANGES.
IGNITION MAY OCCUR AT TYPICAL ELEVATED TEMPERATURE PROCESS
CONDITIONS, ESPECIALLY IN PROCESS OPERATING UNDER VACUUM IF
SUBJECTED TO SUDDEN INGRESS OF AIR, OR OUTSIDE PROCESS
EQUIPMENT OPERATING UNDER ELEVATED PRESSURE IF SUDDEN ESCAPE OF
VAPORS OR MISTS TO THE ATMOSPHERE OCCURS. ANY PROPOSED USE OF
THIS PRODUCT IN ELEVATED TEMPERATURE PROCESSES SHOULD BE
THOROUGHLY EVALUATED TO ASSURE THAT SAFE OPERATING CONDITIONS
(cont.)
Crawford Laboratories, Inc.
Material Safety Data Sheet for: R0-142
Page 4
R0-142.TXT
===============================================================================
-------------------------------------------------------------------------------
SECTION IX - SPECIAL PRECAUTIONS (cont.)
-------------------------------------------------------------------------------
-PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING: (cont.)
ARE ESTABLISHED AND MAINTAINED."
-OTHER PRECAUTIONS:
NOTE
All information and opinions in this report are based on
experience and computer programming which we believe to be
reliable. We believe that the information contained herein is
current as of the date of this report. Since the use of this
information and of these opinions and the conditions of the use
of the product are not within the control of Crawford
Laboratories, Inc. it is the user's obligation to determine the
conditions of safe use of this product.
Crawford Laboratories Inc. makes no warranty, expressed or
implied, as to the accuracy of the information and opinions, and
assumes no responsibility for any damage to person, property or
business arising from such use.
text01
Page 5
|