Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

101-68-8 9016-87-9

File Name: 101-68-8_9016-87-9.asp

Material Safety
Data Sheet P. O. Box 1528 MOUNT AIRY, NC 27030-1528
336-789-9161 FAX 336-789-9586 www.NCFI.com

Dalton, GA Hickory, NC High Point, NC Mount Airy, NC Salt Lake City, UT



PRODUCT IDENTIFICATION

Chemical Family: Polyol Resin System
Trade Name: NCFI 12-002 R
Formula: N/A
Chemical Name: Mixture
Date Prepared: 02/29/08
Synonyms: Polyurethane Resin

INGREDIENTS-HAZARD CLASSIFICATION

Name: CAS NO. % PEL
Tertiary Amine Catalysts1 <8 None Established.
1
Not listed as a carcinogen (NTA, IARC, OSHA)



SHIPPING INFORMATION
Not regulated when shipped domestically by land, water or air



PHYSICAL DATA

>200癋
Boiling Point (癋): Specific Gravity: 1.154
Solubility in Water: High % Volatile by Volume: 0
Appearance and Odor: Amber liquid, faint ammonia odor


FIRE AND EXPLOSION HAZARD DATA

Flash Point (test method): >200癋 (P-M) Flammable Limits (vapor)
Extinguishing Media: Water, dry chemicals, CO2 N/A
Special Fire Fighting Procedures: A self-contained breathing apparatus should be worn to protect against toxic and
irritating vapors.
Unusual Fire and Explosion Hazards:


REACTIVITY DATA

Stability: Stable Conditions to Avoid: N/A
Polymerization: Will not occur Conditions to Avoid: N/A
Incompatibility: Isocyanates and other chemicals that react with hydroxyl groups.
Hazardous Decomposition Products: When burned; CO, CO2, NOx, and aliphatic fragments



This information is furnished without warranty, expressed, or implied, except that it is accurate to the best knowledge of NCFI. The data on this sheet relates only to the specific
material designated herein. NCFI assumes no legal responsibility for use or reliance upon these data.
HEALTH HAZARD DATA

Permissible Exposure Limit:

Effects of Overexposure: May cause skin or eye irritation upon contact. Avoid breathing vapors. The dense vapors
can displace and reduce breathing air in confined or unventilated spaces causing asphyxiation. Overexposure may
cause tremors, confusion, irritation, and may result in cardiac sensitization.


First Aid Procedures

Eyes: Flush with water for at least 15 minutes. See a physician if irritation develops.
Skin: Wash with soap and water at first opportunity.
Inhalation: Move to fresh air if symptoms develop. If breathing is difficult, give
oxygen and call physician.
Ingestion: Induce vomiting; get medical attention.


SPECIAL PROTECTION INFORMATION

Ventilation: Local exhaust ventilation is recommended when working with this product. Uses requiring heating
and/or spraying may require more ventilation or personal protective equipment.

Respiratory Protection: The specific respirator selected must be based on contamination levels of this material found
in the workplace and the working limits of the respirator. A supplied air, full-face mask, positive pressure or
continuous flow respirator or a supplied air hood is required when airborne concentrations are unknown or exceed
threshold limit values. A positive pressure, self contained breathing apparatus can be used in emergencies or other
unusual situations. Full-face air purifying respirators equipped with organic vapor cartridges can be used in certain
situations, see OSHA standard 29CFR 1910.134. All equipment must be NIOSH approved and maintained.

Eye Protection: Goggles or chemical safety glasses.
Gloves: Chemically resistant rubber or plastic.
Other: Avoid eye and skin contact. Eye wash system and showers should be available.


SPILL OR LEAK PROCEDURES

Remove or extinguish ignition or combustion sources.
Contain spill. Absorb with sawdust, etc., and shovel into container. Waste material should be disposed of under
conditions which meet federal, state, and local environmental regulations.
Wash area with detergent and water.


SPECIAL PRECAUTIONS

Store between 65癋 and 85癋 out of sunlight. Keep tightly sealed. Relieve pressure slowly when opening container.
R Component drums can be sent to drum reconditioners or disposed of as ordinary industrial waste in compliance with
pertinent regulations.

CAUTION: Under no circumstances should empty drums be burned or cut open with an electric or gas torch.
Material Safety
Data Sheet P. O. Box 1528 MOUNT AIRY, NC 27030-1528
336-789-9161 FAX 336-789-9586 www.NCFI.com

Dalton, GA Hickory, NC High Point, NC Mount Airy, NC Salt Lake City, UT


PRODUCT IDENTIFICATION

Trade Name: NCFI 12-002 A Chemical Family: Aromatic Isocyanate
Chemical Name: Polymethylene polyphenylisocyanate Formula: N/A
Synonyms: Polymeric MDI Date Prepared: 02/29/08


INGREDIENTS-HAZARD CLASSIFICATION

Name: CAS NO. % PEL
Diphenylmethane diisocyanate (MDI)1 101-68-8 50 0.02 ppm ceiling
Higher polymers of similar structure 9016-87-9 50 None Established.
1
Not listed as a carcinogen (NTA, IARC, OSHA)


SHIPPING INFORMATION
Not regulated when shipped by land, water or air when packaged in single containers of 5000 pounds or less.


PHYSICAL DATA
Boiling Point (癋): 625癋
Specific Gravity: 1.24
Solubility in Water: Insoluble, reacts
% Volatile by Volume: None
Appearance and Odor: Brown liquid, slight aromatic odor


FIRE AND EXPLOSION HAZARD DATA
Flash Point (test method): 390癋 (P-M)
Extinguishing Media: Water, dry chemicals, CO2
Special Fire Fighting Procedures: A self-contained breathing apparatus should be worn to protect against toxic and
irritating vapors.
Unusual Fire and Explosion Hazards: At temperatures above 400癋, MDI can polymerize/decompose causing
pressure build-up in closed containers and possibly rupture. Avoid water contamination in closed containers which
may cause rupture (CO2 is evolved).


REACTIVITY DATA

Stability: Stable Conditions to Avoid: Contamination with water
Polymerization: May occur from contact with water, alcohols, glycols or other materials containing active hydrogens.
Incompatibility: Water, alcohols, amines, strong bases.
Hazardous Decomposition Products: By high heat or fire; CO, CO2, NOx, benzene, toluene, aliphatic fragments,
traces of HCN



This information is furnished without warranty, expressed, or implied, except that it is accurate to the best knowledge of NCFI. The data on this sheet relates only to the specific
material designated herein. NCFI assumes no legal responsibility for use or reliance upon these data.
HEALTH HAZARD DATA

Permissible Exposure Limit: 0.02 ppm ceiling for MDI.

Effects of Overexposure: May cause skin or eye irritation upon contact. Inhalation of MDI vapors may cause
breathlessness, chest discomfort, coughing and reduced pulmonary functions. Exposure may produce asthma-like
symptoms, also may lead to allergic sensitivity.


First Aid Procedures

Eyes: Flush with flowing water for at least 15 minutes, then obtain medical attention.
Skin: Remove contaminated clothing and wash off with soap & water.
Inhalation: Remove to fresh air, administer oxygen if necessary.
Ingestion: Drink large amounts of water. See a physician.

SPECIAL PROTECTION INFORMATION
Ventilation: MDI has a very low vapor pressure at room temperature. General/local ventilation typically control
exposure levels very adequately. Uses requiring heating and/or spraying may require more aggressive engineering
controls or personal protective equipment. Monitoring is required to determine engineering controls.

Respiratory Protection: The specific respirator selected must be based on contamination levels of this material found
in the workplace and the working limits of the respirator. A supplied air, full-face mask, positive pressure or
continuous flow respirator or a supplied air hood is required when airborne concentrations are unknown or exceed
threshold limit values. A positive pressure, self contained breathing apparatus can be used in emergencies or other
unusual situations. Full-face air purifying respirators equipped with organic vapor cartridges can be used in certain
situations, see OSHA standard 29CFR 1910.134. All equipment must be NIOSH approved and maintained.

Eye Protection: Wear goggles or chemical safety glasses.
Gloves: Chemically resistant rubber or plastic.
Other: Avoid eye and skin contact. Eye wash system and safety showers should be available.

SPILL OR LEAK PROCEDURES
Contain spill. Absorb with sawdust, etc., and shovel into open top drum. Decontaminate absorbent and spill area with
2% detergent/water solution. Let waste stand for 1 to 2 days, then dispose of waste in a licensed facility. Respiratory
protection/ventilation is recommended during clean-up.


SPECIAL PRECAUTIONS
Store between 65癋 and 85癋 out of sunlight. Keep tightly sealed to prevent moisture contamination. Relieve pressure
slowly when opening container. Once opened, protect contents from water with dry atmosphere (-40癋 dew point). If
isocyanate becomes contaminated, do not reseal. Empty isocyanate drums or other container should be
decontaminated by filling with water or decontamination solution, preferably outdoors. Allow to stand for 24-48
hours, open to the atmosphere. DO NOT SEAL DRUMS OR CONTAINERS. Drain the drums and puncture to
prevent reuse. Dispose of as ordinary industrial waste.
Material Safety
Data Sheet P. O. Box 1528 MOUNT AIRY, NC 27030-1528
336-789-9161 FAX 336-789-9586 www.NCFI.com

Dalton, GA Hickory, NC High Point, NC Mount Airy, NC Salt Lake City, UT



Date Prepared: 2/22/89
Last Revision Date: 6/16/00



SARA 313 INFORMATION




The isocyanate (A) component product of this NCFI system contains the following chemical(s) subject to the
reporting requirements of Section 313 of Title III of the Superfund Amendments and Reauthorization Act (SARA) of
1986, EPCRA Section 313 (40 CFR 372) and the Comprehensive Environmental Response, Compensation and
Liability Act (CERCLA).




CHEMICAL NAME CAS NUMBER CERCLA RQ CONCENTRATION

Methylene Bis Phenylisocyanate 101-68-8 5000 lbs. See MSDS ?A Component
(Same as Diphenylmethane diisocyanate (MDI)

Polymeric Diphenylmethane diisocyanate 9016-87-9 See MSDS ?A Component




IMPORTANT NOTICE

This notification is a part of the Material Safety Data Sheet document and must not be detached. Any copying and
redistribution of the Material Safety Data Sheet shall include copying of this notice and attaching the copy to the
redistributed Material Safety Data Sheet copies.




This information is furnished without warranty, expressed, or implied, except that it is accurate to the best knowledge of NCFI. The data on this sheet relates only to the specific
material designated herein. NCFI assumes no legal responsibility for use or reliance upon these data.

Search    ENTER KEYWORD
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
9016-87-9_101-68.asp 9016-87-9 101-68-8
67837-35-8_101-68-8_102-60-3_1477-55-0.asp 67837-35-8 101-68-8 102-60-3 1477-55-0
101-68-8_91-20-3_64742-94-5.asp 101-68-8 91-20-3 64742-94-5
101-68-8.asp 101-68-8
63439-95-2_101-68-8_9016-87.asp 63439-95-2 101-68-8 9016-87-9
009016-87-9_101-68-8_75-45.asp 009016-87-9 101-68-8 75-45-6
9016-87-9_101-68-8_108-90-7.asp 9016-87-9 101-68-8 108-90-7
101-68-8_85-68-7_26545-49.asp 101-68-8 85-68-7 26545-49-3
1330-20-7_100-41-4_64742-95-6_108-65-6_101-68-8.asp 1330-20-7 100-41-4 64742-95-6 108-65-6 101-68-8
25723-16-4_77-58.asp 25723-16-4 77-58-7
101-68-8_872-50-4.asp 101-68-8 872-50-4
9016-87-9_101-68-8_811-97.asp 9016-87-9 101-68-8 811-97-2
77-58-7_101-68-8.asp 77-58-7 101-68-8
9016-87-9_101-68-8_26447-40.asp 9016-87-9 101-68-8 26447-40-5
9016-87-9_101-68-8_8052-41-3.asp 9016-87-9 101-68-8 8052-41-3
68130-40-5_9002-86-2_91082-17-6_1330-20-7_64742-47-8_1317-61.asp 68130-40-5 9002-86-2 91082-17-6 1330-20-7 64742-47-8 1317-61-9 101-68-8
9016-87-9_101-68-8_26447-40-5_26471-62.asp 9016-87-9 101-68-8 26447-40-5 26471-62-5
94070-93-6_101-68-8_26447-40.asp 94070-93-6 101-68-8 26447-40-5
9016-87-9_101-68.asp 9016-87-9 101-68-8
9016-87-9_101-68-8_75-45.asp 9016-87-9 101-68-8 75-45-6
101-68-8_9016-87-9.asp 101-68-8 9016-87-9
101-68-8_5285-60-9_6485-22-2.asp 101-68-8 5285-60-9 6485-22-2
9016-87-9_101-68-8_111-46.asp 9016-87-9 101-68-8 111-46-6
101-68-8_9016-87-9_5873-54-1_108-88-3_64771-77-3_584-84-9_91-08.asp 101-68-8 9016-87-9 5873-54-1 108-88-3 64771-77-3 584-84-9 91-08-7 78-93-3
14808-60-7_65997-15-1_39445-23-3_101-68-8.asp 14808-60-7 65997-15-1 39445-23-3 101-68-8
75-45-6_101-68-8_9016-87.asp 75-45-6 101-68-8 9016-87-9
101-68.asp 101-68-8
9016-87-9_38-40-4_101-68.asp 9016-87-9 38-40-4 101-68-8
59675-67-1_112-15-2_101-68-8_9016-87.asp 59675-67-1 112-15-2 101-68-8 9016-87-9
9016-87-9_101-68-8_5873-54.asp 9016-87-9 101-68-8 5873-54-1
7447-40-7_25791-96-2_9016-87-9_7647-14-5_101-68-8_1332-58.asp 7447-40-7 25791-96-2 9016-87-9 7647-14-5 101-68-8 1332-58-7 120962-03-0 26447-40-5
80-62-6_101-68-8_9016-87-9_64742-55-8_26447-40-5.asp 80-62-6 101-68-8 9016-87-9 64742-55-8 26447-40-5
9016-87-9_101-68-8_53862-89-8.asp 9016-87-9 101-68-8 53862-89-8
101-68-8_9016-87-9_26447-40-5_103-71.asp 101-68-8 9016-87-9 26447-40-5 103-71-9
101-68-8_105-76-0_9003-11-6_9082-00-2.asp 101-68-8 105-76-0 9003-11-6 9082-00-2
9016-87-9_101-68-8_5873-54.asp 9016-87-9 101-68-8 5873-54-1
101-68-8_64742-95-6_11-17.asp 101-68-8 64742-95-6 11-17-0
101-68-8_74-98.asp 101-68-8 74-98-6
13463-67-7_26761-40.asp 13463-67-7 26761-40-0
811-97-2_101-68-8_9016-87-9.asp 811-97-2 101-68-8 9016-87-9
75-45-6_101-68-8_9016-87.asp 75-45-6 101-68-8 9016-87-9
9016-87-9_101-68-8_26447-40.asp 9016-87-9 101-68-8 26447-40-5
101-68-8_108-32-7.asp 101-68-8 108-32-7
009016-87-9_101-68-8_75-45.asp 009016-87-9 101-68-8 75-45-6
26447-40-5_101-68.asp 26447-40-5 101-68-8
9016-87-9_101-68-8_26447-40.asp 9016-87-9 101-68-8 26447-40-5
328235-05-8_115-10-6_74-98-6_75-28-5_101-68-8.asp 328235-05-8 115-10-6 74-98-6 75-28-5 101-68-8
811-97-2_101-68-8_9016-87.asp 811-97-2 101-68-8 9016-87-9
1317-65-3_85-68-7_13463-67-7_1330-20-7_1305-78-8_101-68-8_100-41.asp 1317-65-3 85-68-7 13463-67-7 1330-20-7 1305-78-8 101-68-8 100-41-4
9016-87-9_005-00-9_101-68-8_103-71.asp 9016-87-9 005-00-9 101-68-8 103-71-9


HBCChem,Inc

Chemical Information Net chemcas.orgCopyright Reserved

Trading Lead

Leputech HPLC Laboratory