Material Safety Data Sheet
R e v i si o n : 0 1 / 0 9 / 20 0 1
Haza rd inform ation is p rovide d for co mplia nce w ith both the UK Chem icals
(Hazard Inform ation and Pac kaging) (CHIP ) Regulations and the US H azard
C o m m u n i c a ti o n S ta n d a r d ( H C S )
I D E N T IF I C A T IO N O F T H E PRODUCT NA ME: PRODUCT CO DE: EEC NUMBER:
S U B S T A N CE / P RE P A R A TI O N F a s t G re e n F C F (C . I . 4 2 0 5 3 ) 32814 None
AND COMPANY
SUPPLIER: Emergency Contact :
U S B C o r p o ra t io n , 2 6 1 1 1 M il e s R oa d , C le v e l an d , O h io 4 4 1 2 8 P h o n e: ( 2 1 6 ) 7 6 5 - 5 0 0 0 C h e m t r ec ( 8 0 0 ) 4 2 4 - 9 3 0 0
O u t s id e U S A & C a n a da 7 0 3 5 2 7 3 8 8 7
C O M P O S I T IO N /
%WT TLV
HAZARDOUS COMPONENTS HAZARD CAS NO. CHIP R & S Phrases
F a s t G re e n F C F 2353 -45-9 ~100% --- R:20/21/22 Harmful by
inhalat ion, in co ntact w ith skin
and if swallowed
R:40 Possible risk of
irreversible effects
S:22 Do not breathe dust
S:36 /37 W ear suit able
protective clothing and gloves
H A Z A R D S ID E N T IF I C AT I O N CHIP
Carcinogen, Category 3
HCS
Irritant, Group 3 Carcinogen
FIRST-AID MEASURES EYES : Flush w ith wate r for 15 m inutes. Se ek me dical advic e if irritation persists .
SKIN: Flush with water, then wash thoroughly with soap and water. Remove contaminated clothing and wash
before reuse. Seek medical attention if irritation persists.
INHALA TION: Re move th e victim from exposure an d move to fresh air. If breathing is difficult, give oxygen . If
not breath ing, give artificial re spiration. K eep victim quiet and warm . Seek im media te med ical attention .
INGESTION: Drink water and seek immediate medical attention. Avoid alcoholic beverages. Never give
anything by mo uth to an uncon scious pe rson.
F I R E- F IG H T I N G I N F O RM A T I O N Use m edia su itable to exting uish th e supp orting o r surrou nding fire. W ear NIO SH (o r equiv alent) a pprov ed self
contained breathing apparatus. For small fires only: use carbon dioxide, dry powder or foam. Emits toxic fumes
under fire conditions.
Flash Point = No data available.
ACCIDENTAL RELEASE MEA SURES Wear appropriate personal protective equipment and clothing including lab coat, safety glasses, gloves and
NIOSH -approved res pirator. Collect in a man ner that does no t create dust and place in a suitable w aste
container. Avoid contact of material with skin or eyes. Use adequate ventilation.
HANDLING AND STORAGE Wear appropriate personal protective equipment and clothing including lab coat, safety glasses, gloves and
NIOSH -approved res pirator. Avoid con tact of material w ith skin or eyes. Use adequate v entilation. Store
ambient away from strong oxidizing agents. Protect from moisture.
This data sheet is based upon information believed to be reliable. The Company makes no statement or warranty as to the accuracy or completeness of the information
contained herein which is offered for your consideration, investigation and verification. Any use of the information contained in this data sheet must be determined by the user
to be in accordance with appropriate applicable regulations.
For Further Asia Pacific Canada Former Soviet Union Japan Norway Spain USA
Information, +852 2811 8693 1 800 463 5800 +7 (095) 232 0250 81 3 5331 9337 63 89 23 10 935 944 950 USB Corporation
contact your (216) 765-5000
local USB Australia Central and East Europe France Latin America Portugal Sweden If purchased from
authorized +61 2 9894 5188 +43 1 982 3826 0169 18 28 00 +55 11 3667 5700 01 417 70 35 018 164000 Amersham Pharmacia
distributor, Biotech use
Amersham Austria Denmark Germany Middle East and Africa South East Asia Switzerland 1 800 526 3593
Pharmacia 01 576 0616 10 +45 4516 2400 07 61 49 03 0 +30 (1) 96 00 687 60 3 724 2080 01 802 81 50
Biotech
Belgium Finland Italy Netherlands South East Europe UK
0800 73888 358 (9) 512 3940 02 27322 1 0165 580 410 +43 (1) 982 3826 0800 515313
MSDS information may be continued on back of page.
P E R S O N AL P R O T EC T I O N Wear appropriate personal protective equipment and clothing including lab coat, safety glasses, gloves and
NIOSH-approved respirator. A qualified industrial hygienist should evaluate the need for respiratory protection.
Use respiratory protection approved by NIOSH (or equivalent) and appropriate to the hazard. Avoid contact of
material with skin o r eyes. Mec hanical ventilation or local exh aust as neede d to control expo sure to dust,
vapors or mists. Access to a safety shower and eye-wash.
PHYSICAL AN D CHEMICA L App earan ce: Da rk gree n pow der w ith me tallic luste r Boiling P oint: N o data availab le
Vapo r Press ure: N o data availab le Vapo r Den sity: No data av ailable
PROPERTIES
Solub ility (Wa ter): So luble Specific Gra vity: N o data availab le
Perce nt Vo latile: No data av ailable Evapo ration R ate: No data av ailable
C h e m i c a l f o r m u la : C 3 7 -H 3 6 - N 2 - O 1 0 -S 3 酶P N a
3
S T A B I L IT Y A N D R E A C T I V IT Y Product is stable. Incompatible with strong oxidizing agents. Protect from moisture. Hazardous decomposition
products include carbon monoxides, carbon dioxide, nitrogen oxides and sulfur dioxides. Hazardous
polymerization will not occur.
T O X I C OL O G I CA L I NF O R M A T IO N EFFECTS OF OVEREXPO SURE:
EYES: Contact may cause irritation.
SKIN: Contact may cause irritation and hypersensitive individuals may experience an allergic reaction. May be
harmful if absorbed through the skin.
INHALATION: May cause irritation to the respiratory system. May be harmful if inhaled.
INGESTION: Chronic ingestion or excessive dosage may cause irritation to the mouth, throat, esophagus and
gastrointestinal tract. May be harmful if swallowed. Possible carcinogen.
A D D I T IO N A L I N FO R M A T I O N :
T u m o r i ge n i c , m u t a t io n a n d to x i c it y d a ta l is t e d in R T E C S u n d er B Q 4 4 2 5 0 0 0 .
Oral Rat LD50 = > 2 gm/kg (1989) Details of toxic effects not reported other than lethal dose value.
Carcino genicity d ata:
IARC C ancer R eview : Anima l - Limited Ev idence (1 978).
Hum an - No A dequa te Data (1 978).
Group 3 - Agent is n ot classifiable a s to its carcino genicity to huma ns (198 7).
Definition(s ):
IARC = International Agency for Research on Cancer
RTECS = Reg istry of Toxic Effects of Chemical Substances.
E C O L O G IC A L IN F O R M A T IO N No inf orma tion av ailable
D I S P O S A L C O N S I D E RA T I O N S Dispose of material in accordance with applicable local, state, and federal regulations.
T R A N S P O RT A T I ON I N F OR M A T I O N US DOT / IATA: No applicable information.
R E G U L AT O R Y IN F O R M A T IO N RCRA - No applicable information.
SARA 302 - No applicable information.
SARA 313 - No applicable information.
EPA TSCA Section 8(b) - Chemical Inventory.
Exposure Limits - Not established.
California Proposition 65 - No applicable information.
|