MATERIAL SAFETY DATA SHEET
For chemicals, coatings and related material
DATE: SUPERSEDES: PREPARED BY:
January 8, 2008 October 10, 2007 ECORE International
Manufacturer
NAME: ECORE International, Inc.
ADDRESS: 715 Fountain Avenue EMERGENCY PHONE NUMBER
ADDRESS: P.O. Box 989 DAY: (717) 295-3400
ADDRESS: Lancaster, PA CHEMTREC: 800-424-9300
ZIP CODE: 17608-0989 INFORMATION PHONE NUMBER: 800-322-1923
Section I ?Product
NUMBER: P-700 H.M.I.S. Hazard Codes
1
HEALTH
FLAMMABILITY 1
NAME: ECOguard
0
REACTIVITY
CLASS: Floor Sealer
CAS NUMBER: Not Established
PERSONAL PROTECTION B
Section II ?Information on Ingredients
Ingredient: Material Description Percent By Weight CAS Registry Number
1-METHYL-2-PYRROLIDINONE <13.0 872-50-4
Section III ?Hazards Identification
Eye Hazards
May cause eye irritation and redness
Skin Hazards
May cause skin irritation.
Ingestion Hazards
May be harmful if swallowed or inhaled.
Inhalation Hazards
May be harmful if or inhaled.
Section IV ?First Aid Measures
Eye
In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention.
Skin
Wash thoroughly with soap and water. Get medical attention immediately if irritation develops or persists.
Ingestion
Dilute by drinking large quantities of water. Call a physician or poison control center immediately.
Inhalation
Remove to fresh air. Get medical attention.
Section V ?Fire Fighting Measures
COC Flash Point: >199.9 癋; >93.3 癈
Autoignition Point: N/Av 癋
Lower Explosive Limit: 1.3%
Upper Explosive Limit: 9.5%
Flammable Properties: Non-combustible
Fire and Explosion Hazards
No known unusual hazards in a fire/explosion situation
Extinguishing Media
Any available
Fire Fighting Instructions
Wear self-contained, positive pressure breathing apparatus.
...ECORE International ECOguard Floor Sealer, Page 1 of 4
MATERIAL SAFETY DATA SHEET
For chemicals, coatings and related material
Section VI ?Accidental Release Measures
Initial Containment:
Absorb spills with inert material. Flush the area thoroughly with water and scrub to remove residue.
Large Spills Procedure:
Recover and reclaim product where possible. Flush spill area with water to wastewater treatment system.
Small Spills Procedure:
Small spills may be flushed with water.
Section VII ?Handling and Storage
Handling and Storage Precautions
Keep containers tightly closed when not in use.
Recommended Storage Temperature
Minimum: 4 C (39.2 F)
Maximum: 40 C (104.0 F)
Handling Precautions
Keep containers closed when not in use
Storage Precautions
Store in a cool dry place. Keep from freezing. Keep container closed when not in use.
Section VIII ?Exposure Controls/Personal Protection
Engineering Controls
No special ventilation requirements.
Eye/Face Protection
Wear safety glasses.
Skin Protection
Protective gloves.
Respiratory Protection
Under normal use conditions, with adequate ventilation, no special handling equipment is required.
Other/General Protection
Eye wash and safety shower in the work area.
Ingredient(s) ?Exposure Limits
No Information Available.
Section IX ?Physical and Chemical Properties
Appearance
Translucent
Odor
Characteristic
Chemical Type: Mixture
Physical State: Liquid
Melting Point: N/Av 癋
Boiling Point: 100 癋
Specific Gravity: 1.02 (Water =1)
pH: 7-9
Solubility in water: Soluble
...ECORE International ECOguard Floor Sealer, Page 2 of 4
MATERIAL SAFETY DATA SHEET
For chemicals, coatings and related material
Section X ?Stability and Reactivity
Stability: STABLE
Hazardous Polymerization: WILL NOT OCCUR
Incompatible Materials
Strong oxidizers
Hazardous Decomposition Products
Ammonia
Conditions to Avoid:
None known.
XI ?Toxicological Information
Skin Effects:
Ammonium chloride LD50> 8000 mg/kg (Dermal; Rabbit).
Acute Oral Effects:
Oral LD50 > 4200 mg/kg (rat).
XII ?Ecological Information
No Information Available...
XIII ?Disposal Considerations
Waste Disposal:
Treat or dispose of waste material in accordance with all local, state/provincial, and national requirements.
Contaminated Materials:
Treat or dispose of waste material in accordance with all local, state/provincial, and national requirements.
XIV ?Transport Information
Proper Shipping Name
NOT REGULATED BY D.O.T.
XV ?Regulatory Information
U.S. Regulatory Information
This product is not known to contain any known materials on the Priority Substance List under CEPA.
SARA Tit1e III - Section 313
I-METHYL-2-PYRROLIDINONE (872-50-4)
Miscellaneous Information:
This material or all of its components are listed on the Canadian Domestic Substances List (DSL).
This material or all of its components are listed on the Inventory of Existing Chemical Substances under the Toxic Substance Control Act
(TSCA).
XVI ?Other Information
HMIS Rating
Health: 1
Fire: 1
Reactivity: 0
PPE: B
Revision/Preparer Information
MSDS Preparer: Gregory M. Bachman
...ECORE International ECOguard Floor Sealer, Page 3 of 4
MATERIAL SAFETY DATA SHEET
For chemicals, coatings and related material
ABBREVIATIONS USED:
N/Av = Information or data Not Available NTP = National Toxicology Program
IARC = International Agency for Research on Cancer NIOSH = National Institute of Occupational Safety and Health
ACGIH = American Conference on Governmental Industrial Hygienists OSHA = Occupational Safety and Health Administration
PEL = Permissible Exposure Limit (8-hr. TWA) (OSHA) TLV = Threshold Limit Value (8-hr. TWA) (ACGIH)
STEL = Short Term Exposure Limit (15-min. TWA) (OSHA) C = Ceiling Value
HMIS = Hazardous Material Information System
DISCLAIMER
This information is furnished without warranty, representation, or license of any kind, except that this information is accurate to the best of ECORE
International's knowledge, or is obtained from sources believed by ECORE International to be accurate. No warranty is expressed or implied regarding
the accuracy of this information or the results to be obtained from its use thereof. ECORE International assumed no responsibility for injuries proximately
caused by the use of the Material if reasonable safety procedures are not followed as stipulated in this Data Sheet. Additionally, ECORE International
assumes no responsibility for injuries proximately caused by abnormal use of the Material even if reasonable safety procedures are followed. Buyer
assumes the risk in its use of the Material.
REASON FOR REVISION: REISSUE REQUIRED:
Not Applicable
...ECORE International ECOguard Floor Sealer, Page 4 of 4
|