MATERIAL SAFETY DATA SHEET                             EOS- A/P-EC CLEANER
REVISION DATE: APRIL 30,2003 (Efflorescence Cleaner) PAGE 1 OF4
============================================================================
SECTION 1. PRODUCT IDENTIFICATION
ORIGINAL: MARCH 26, 1999
REVISION: APRIL 30,2003
REASON FOR REVISION: TRANSPORT INFORMATION CHANGES BASED ON CONTAINER SIZE.
PRODUCT NAME(S): EOS A/P-EC ALL PURPOSE MASONRY CLEANER
EOS ALL PURPOSE MASONRY/EFFLORESCENCE CLEANER
EOS SYSTEMS
ENDUR-O-SEAL USA, INC.
12502 LAZYWOOD
PINEHURST, TEXAS, 77362
TEL (281) 356-5117 /FAX (281) 356-9332

CHEMICAL FAMILY: N/A; PROPRIETORY
FORMULA: PROPRIETARY FORMULATION

THESE PRODUCTS ARE AQUEOUS BASED PENETRATING COMPOUNDS FOR REMOVAL
OF SALT, LIME STAINS FROM PORPOUS AND NON POROUS CEMENTITIOUS OR CLAY
CONSTRUCTION MATERIALS. REFER TO PRODUCT BULLETINS FOR SPECIFIC
APPLICATION DATA.

=========================================================================
SECTION 2. INGREDIENTS/ COMPOSITION
---------------------------------------------------------------------------------------------------------------------------------
ACGIH TLV OSHA PEL APPROX.
PRODUCTS/
TWA STEL TWA STEL UNITS WGHT.%
CAS NUMBER(S)

NON HAZARDOUS
TRADE SECRET FDA&FEMA "GENERALLY RECOGNIZED AS SAFE" < 7
EXPANSION AGENTS (MIXTURE)
68155-38-4 NE NE NE NE NA <2
112-90-3
68554-67-6
CYCLIC AMIDE NE NE NE NE NA <20
872-50-4
DEIONIZED WATER
112-90-3 NE NE NE NE NA 40 - 60
TRADE SECRET NE NE NE NE NA <19
HAZARDOUS
HYDROGEN PEROXIDE
7722 ?84 ?1 (ACGIH TLV @ CONCENTRATION) 7.1 PPM, 10MG/M3, - 8 HR. TWA
(OSHA PEL @ CONCENTRATION) 7.1 PPM, 10MG/M3, - 8 HR. TWA

HYDROGEN CHLORIDE SOLUTION
7647 ?01 ? 5 PPM 5PPM PPM <1
=========================================================================
SECTION 3. HAZARDS IDENTIFICATION
---------------------------------------------------------------------------------------------------------------------------------
POTENTIAL HEALTH EFFECTS:

INGESTION:
THIS MATERIAL IS A SIGNIFICANT HEALTH HAZARD IF INGESTED IN LARGE QUANTITIES. IRRITATION OF
MUCOUS MEMBRANES OF THROAT, ESOPHAGUS AND STOMACH WHICH MAY RESULT IN VOMITTING,
DIGESTIVE TRACT SHOCK OR DEATH MAY OCCUR.

SKIN CONTACT:
NOT SIGNIFICANT: MAY CAUSE MILD SKIN IRRITATION. SKIN CHAPPING MAY DEVELOP AFTER EXTREME
REPEATED CONTACT,
INHALATION:
MATERIAL SAFETY DATA SHEET EOS - A/P-EC CLEANER PAGE 2 OF 4
REVISION DATE: APRIL 30, 2003
============================================================================================
INHALATION OF CONCENTRATED VAPORS CAN CAUSE MILD IRRITAION OF THE UPPER RESPIRATORY
TRACT (NOSE, THROAT) POSSIBLE FOLLOWED BY CHEST DISCOMFORT, COUGH AND SHORTNESS OF
BREATH.
EYE CONTACT:
MAY CAUSE A MILD BURNING SENSATION/ IRRITTATION TEARING, REDNESS AND SWELLING. PROLONGED
UNTREATED CONTACT WILL CAUSE SEVERE BURNS AND OR PERMANENT DAMAGE.

MEDICAL CONDITIONS AGGRAVATED AS STATED ABOVE.

CHRONIC EFFECTS / CARCINOGENICITY:
THIS PRODUCT OR ONE OF ITS INGREDIENTS PRESENT 0.1% OR MORE IS NOT LISTED AS A CARCINOGEN OR
SUSPECTED CARCINOGEN BY OSHA, IARC, NTP OR ACGIH.

MEDICAL LIMITAIONS:
RESTRICT CONTACT BY PERSONS WITH ACNE, SKIN SENSITIVITY OR SKIN DISEASESFOR EXPOSURE COULD
AGGRAVATE THESE CONDITIONS.

EFFECTS OF OVER EXPOSURE:
ACUTE: CENTRAL NERVOUS SYSTEM DEPRESSION WITH EXTREME EXPOSURE; EFFECTS MAY INCLUDE
ANESTHESIA, COMA, RESPIRATORY ARREST. OXYGEN DEPRIVATION IS POSSIBLE IF WORKING IN A
CONFINED NON VENTILATED AREA.

CHRONIC: NO KNOWN MAJOR CUMMULATIVE OR LATENT EFFECTS HAVE BEEN REPORTED.
=========================================================================
SECTION 4. FIRST AID MEASURES
---------------------------------------------------------------------------------------------------------------------------------
INGESTION:
DO NOT INDUCE VOMITING. IF VOMITING OCCURS KEEP AIRWAY CLEAR. NEVER GIVE ANYTHING BY MOUTH
TO AN UNCONSCIOUS PERSON. SEEK MEDICAL ATTENTION IMMEDIATELY. IF SWALLOWED IN LARGE
AMOUNTS OXYGEN MAY BE RELEASED. THE DISTENTION OF THE STOMACH OR ESOPHAGUS MAY BE
INJURIOUS. INSERTION OF A GASTRIC TUBE MAY BE ADVISABLE.

SKIN CONTACT:
WASH WITH SOAP AND WATER. REMOVE CONTAMINATED CLOTHES AND FOOTWEAR. SEEK MEDICAL
ATTENTION IF SYMPTOMS ARISE.

INHALATION:
REMOVE TO FRESH AIR, RESTORE BREATHING IF NEEDED; ADMINISTER OWYGEN; SEEK MEDICAL HELP IF
REQUIRED.

EYE CONTACT:
FLUSH EYES THOROUGHLY WITH LARGE AMOUNTS OF WATER FOR 15 MINUTES. SEEK MEDICAL
ATTENTION.

NOTES TO PHYSICIAN:
GASTRIC LAVAL ONLY IF A LARGE QUANTITY HAS BEEN INGESTED. TREAT SYMPTOMATICALLY.
=========================================================================
SECTION 5. FIRE FIGHTING MEASURES
---------------------------------------------------------------------------------------------------------------------------------

FLASH POINT: (AQUEOUS SOLUTION) NA NA
METHOD: TCC
>285 癈 >513 癋
AUTOIGNITION TEMP:
FLAMMABLE LIMITS IN AIR:
% BY VOLUME UPPER N/A
% BY VOLUME LOWER N/A
SENSITIVITY TO MECHANICAL IMPACT: NO
SENSITIVITY TO STATIC DISCHARGE: NONE EXPECTED; MATERIAL HAS A FLASHPOINT ABOVE 200 癋.

EXTINGUISHING MEDIA:
FOAM, DRY CHEMICAL, CARBON DIOXIDE. WATER MAY BE INEFFECTIVE UNLESS USED IN FAVORABLE
CONDITIONS BY TRAINED FIREFIGHTERS.

SPECIAL FIREFIGHTING PROCEDURES: NONE
MATERIAL SAFETY DATA SHEET EOS A/P-EC CLEANER PAGE 3 OF 4
REVISION DATE: APRIL, 30, 2003
=========================================================================
SECTION 6. ACCIDENTAL RELEASE MEASURES
---------------------------------------------------------------------------------------------------------------------------------
CONFINE AREA TO CLEANUP PERSONNEL. VENTILATE AREA AND WEAR PROTECTIVE GEAR AS REQUIRED,
WIPE UP SPILL WITH AN INERT MATERIAL AND PLACE IN AN APPROVED NON METALLIC CONTAINER FOR
DISPOSAL. REMOVE SOURCES OF IGNITION. DISPOSE OF EXPENDED MATERIAL AND ABSORBENTS WITH
ALL APPLICABLE LOCAL, STATE AND FEDERAL REGULATIONS.
=========================================================================
SECTION 7. HANDLING AND STORAGE
--------------------------------------------------------------------------------------------------------------------------------
-USE A PROPER GROUP STRAP ON HANDLING AND PUMPING EQUIPMENT.
-PREFERABLY UTILIZE EXPLOSION PROOF ELECTRICAL EQUIPMENT.
-RECOMMENDED STORAGE SHOULD BE ABOVE 0 癈 (32 癋) AND BELOW 38 癈 (100 癋.)
-KEEP ORIGINAL OR STORAGE CONTAINERS CLOSED WHEN NOT IN USE.
-AVOID BREATHING VAPORS.
-AVOID CONTACT WITH SKIN AND EYES.
-USE ONLY IN WELL VENTILATED AREAS.
=========================================================================
SECTION 8. PERSONAL PROTECTION/ EXPOSURE LIMITS
---------------------------------------------------------------------------------------------------------------------------------
RESPIRATORY PROTECTION: USE IN WELL VENTILATED AREA. USE APPROVED NIOSH RESPIRATOR IF TLV
IS EXCEEDED.

PROTECTIVE GLOVES: RUBBER

EYE AND FACE PROTECTION: SAFETY GLASSES

ENGINEERING: EXHAUST VENTILATION, SHOWERS, EYE WASH STATIONS
=========================================================================
SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES
---------------------------------------------------------------------------------------------------------------------------------
100 癈 212 癋
INTITAL BOILING POINT:
VAPOR PRESSURE (20 癈) <5
VAPOR DENSITY: (AIR=1) UNKNOWN
MELTING POINT: UNKNOWN
0 癈 32 癋
FREEZING POINT:
APPEARANCE: HAZY CLEAR LIQUID
ODOR: SLIGHT AMINE / LEMON ODOR
EVAPORATION RATE (BuAc =1) <1
VOLITILE CHARACTERISTICS NEGLIBLE
SPECIFIC GRAVITY (WATER = 1) 1.03
SOLUBILITY IN H20 AT 20 癈 COMPLETE
=========================================================================
SECTION 10. STABILITY AND REACTIVITY
---------------------------------------------------------------------------------------------------------------------------------
STABILITY: STABLE
HAZARDOUS POLYMERIZATION: WILL NOT OCCUR
HAZARDOUS THERMAL DECOMPOSITON/ COMBUSTION PRODUCTS: FUMES/ SMOKE/ CARBON
MONOXIDE/ ALDEHYDES/ SILICON DIOXIDE/ FORMALDEHYDE/
INCOMPATIBILITY (MATERIALS TO AVOID): STRONG OXIDANTS/ CONCENTRATED OXYGEN/ SODIUM HYPO
CHLORITE/ CALCIUM HYPO CHLORITE.

CONDITONS TO AVOID: KEEP AWAY FROM HEAT, SPARKS, AND L=FLAMES, AVOID ANY SOURCE
OF IGNITION. AVOID CONTACT WITH ACIDIC, BASIC, OR OXIDIZING
AGENTS AND METALLIC CATALSYTS LIKE TIN SOAPS AND NOBLE
METALS.
MATERIAL SAFETY DATA SHEET EOS A/P-EC CLEANER PAGE 4 OF 4
REVISION DATE: APRIL 30,2003
=========================================================================
SECTION 11. TRANSPORT INFORMATION
---------------------------------------------------------------------------------------------------------------------------------
SHIPPING NAME: AQUEOUS BIODEGRADABLE MASONRY CLEANER
DOT HAZARD CLASS: N/A (Below Threshold quantity of 30 gallons)
PLACARDS: N/A
DOT I.D. NUMBER: N/A
REPORTABLE QUANTITY: 100 LBS.
PLEASE CHECK WITH MANUFACTURER FOR TRANSPORT INFORMATION FOR CONTAINERS EXCEEDING 30
GALLONS.
=========================================================================
SECTION 12. REGULATORY INFORMATION
---------------------------------------------------------------------------------------------------------------------------------
TSCA: THIS MATERIAL OR ITS COMPONENTS ARE LISTED ON THE TSCA INVENTORY LIST AND
COMPLY WITH APPLICABLE RULES AS OF THIS WRITING.

SARA 302: NONE FOUND

SARA 311 & 312: NONE FOUND

SARE 313: THIS MATERIAL DOES NOT CONTAIN ANY INGREDIENTS ON THE LIST OF TOXIC
CHEMICALS SUBJECT TO SECTION 313 OF THE SUPERFUND AMENDEMENTS AND REAUTHORIZATION ACT
OF 1986 (SARA TITLE III), IN EXCESS OF THE APPLICABLE MINIMUM CONCENTRATIONS AS PER SECTION
372.38 (a).


HAZARD RATING SYSTEM:
MFPA No. 704, 1985 EDITION 1 HEALTH 0 FLAMMABLILITY 2 REACTIVITY

HMIS 1 HEALTH 0 FLAMMABILITY 2 REACTIVITY

=========================================================================
SECTION 13. ADDITIONAL INFORMATION
---------------------------------------------------------------------------------------------------------------------------------
THIS MATERIAL SAFETY DATA SHEET HAS BEEN PREPARED IN ACCORDANCE WITH CFR 1910. 1200. ALL
INFORMATION, RECOMMENDATIONS AND SUGGESTIONS APPEARING HEREIN CONCERNING OUR
PRODUCT(S) ARE BASED UPON TESTS AND DATA BELIEVED TO BE RELIABLE, HOWEVER, IT IS THE USER'S
SOLE RESPONSIBILITY TO DETERMINE THE SAFETY, TOXICITY AND SUITABILITY FOR HIS OWN USE OF THE
PRODUCTS DESCRIBED HEREIN. SINCE THE ACTUAL USE OF THESE PRODUCTS IS BY OTHERS AND BEYOND
OUR CONTROL, NO GUARENTEE EXPRESSED OR IMPLIED IS MADE BY ENDUR-O-SEAL USA, INC. AS TO THE
EFFECTS OF SUCH USE, INCLUDING THE RESULTS TO BE OBTAINED OR THE SAFETY AND TOXICITY OF THE
PRODUCTS NOR DOES ENDUR-O-SEAL USA, INC ASSUME ANY LIABILITY ARISING OUT OF THE USE BY
OTHERS OF THE PRODUCTS REFFERED TO HEREIN. NOR IS THE INFORMATION HEREIN TO BE CONSTRUED
AS ABSOLUTELY COMPLETE SINCE ADDITIONAL INFORMATION MAY BE NECESSARY OR DESIRABLE WHEN
PARTICULAR OR EXCEPTIONAL CONDITIONS OR CIRCUMSTANCES EXIST OR BECUASE OF APPLICABLE LAWS
OR GOVERNMENT REGULATION.




NA = NOT APPLICABLE
NE = NOT ESTABLISHABLE
NF = NONE FOUND

Search    ENTER KEYWORD
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
64741-88-4_64742-54-7_68649-42.asp 64741-88-4 64742-54-7 68649-42-3
872-50-4.asp 872-50-4
07-31-0_06-15-0_64741-65-7_64741-66-8_8042-47-5_68476-85-7_872-50-4.asp 07-31-0 06-15-0 64741-65-7 64741-66-8 8042-47-5 68476-85-7 872-50-4
34590-94-8_67-63-0_872-50-4.asp 34590-94-8 67-63-0 872-50-4
34590-94-8_872-50-4_121-44-8.asp 34590-94-8 872-50-4 121-44-8
872-50-4.asp 872-50-4
111-76-2_872-50-4.asp 111-76-2 872-50-4
872-50-4_111-76-2_7732-18-5.asp 872-50-4 111-76-2 7732-18-5
64741-65-7_64741-66-8_872-50-4_8042-47-5_68476-85-7.asp 64741-65-7 64741-66-8 872-50-4 8042-47-5 68476-85-7
8052-41-3_872-50-4.asp 8052-41-3 872-50-4
872-50-4_1330-20-7_100-41-4_71-43-2.asp 872-50-4 1330-20-7 100-41-4 71-43-2
14807-96-6_7727-43-7_111-76-2_112-34-5_872-50.asp 14807-96-6 7727-43-7 111-76-2 112-34-5 872-50-4
82657-04-3_872-50-4_67-63-0_75-28-5_74-98-6.asp 82657-04-3 872-50-4 67-63-0 75-28-5 74-98-6
872-50.asp 872-50-4
872-50.asp 872-50-4
872-50-4_1119-40-0_627-93-0.asp 872-50-4 1119-40-0 627-93-0
100646-51-3_64742-94-5_872-50-4.asp 100646-51-3 64742-94-5 872-50-4
64-17-5_34590-94-8_872-50-4_68476-86-8_1330-20-7.asp 64-17-5 34590-94-8 872-50-4 68476-86-8 1330-20-7
627-93-0_1119-40-0_106-65-0_872-50-4.asp 627-93-0 1119-40-0 106-65-0 872-50-4
71751-41-2_14769-73-4_872-50-4.asp 71751-41-2 14769-73-4 872-50-4
872-50.asp 872-50-4
13463-67-7_21645-51-2_1336-21-6_872-50-4_121-44-8_25265-77.asp 13463-67-7 21645-51-2 1336-21-6 872-50-4 121-44-8 25265-77-4 7732-18-5 34590-94-8 1317-65-3
68155-38-4_112-90-3_68554-67-6_872-50-4.asp 68155-38-4 112-90-3 68554-67-6 872-50-4
872-50-4_112-34-5_57-55-6_5131-66.asp 872-50-4 112-34-5 57-55-6 5131-66-8
57-55-6_121-44-8_872-50-4.asp 57-55-6 121-44-8 872-50-4
107-21-1_872-50-4.asp 107-21-1 872-50-4
872-50-4_112-34-5_57-55.asp 872-50-4 112-34-5 57-55-6
872-50-4_5989-27-5_9016-45.asp 872-50-4 5989-27-5 9016-45-9
100-41-4_1330-20-7_872-50-4_28262-63-7.asp 100-41-4 1330-20-7 872-50-4 28262-63-7
64741-65-7_64741-66-8_8042-47-5_68476-85-7_872-50-4.asp 64741-65-7 64741-66-8 8042-47-5 68476-85-7 872-50-4
872-50-4.asp 872-50-4
872-50.asp 872-50-4
872-50-4.asp 872-50-4
7732-18-5_872-50-4_50-00.asp 7732-18-5 872-50-4 50-00-0
01-08-0_64742-94-5_68476-86-8_64741-44-2_9003-13-8_872-50-4.asp 01-08-0 64742-94-5 68476-86-8 64741-44-2 9003-13-8 872-50-4
872-50-4.asp 872-50-4
7732-18-5_111-76-2_112-34-5_872-50-4.asp 7732-18-5 111-76-2 112-34-5 872-50-4
7732-18-5_872-50-4_57-55-6_25498-49-1_112945-52.asp 7732-18-5 872-50-4 57-55-6 25498-49-1 112945-52-5
107-98-2_872-50-4_770-35-4_67-56-1_1310-58-3.asp 107-98-2 872-50-4 770-35-4 67-56-1 1310-58-3
872-50.asp 872-50-4
123-42-2_67-63-0_115-10-6_872-50-4_108-88-3.asp 123-42-2 67-63-0 115-10-6 872-50-4 108-88-3
872-50-4.asp 872-50-4
763-69-9_872-50-4_57018-52-4.asp 763-69-9 872-50-4 57018-52-4
577-11-7_872-50-4.asp 577-11-7 872-50-4
60207-90-1_94361-06-5_872-50.asp 60207-90-1 94361-06-5 872-50-4
7732-18-5_53320-86-8_872-50-4_67-66.asp 7732-18-5 53320-86-8 872-50-4 67-66-3
34590-94-8_872-50-4.asp 34590-94-8 872-50-4
9005-64-5_872-50-4.asp 9005-64-5 872-50-4
101-68-8_872-50-4.asp 101-68-8 872-50-4
12-44-8_101-77-9_73138-88-2_1330-20-7_71-43-2_108-88-3_9002-84.asp 12-44-8 101-77-9 73138-88-2 1330-20-7 71-43-2 108-88-3 9002-84-0 872-50-4


HBCChem,Inc

Chemical Information Net chemcas.orgCopyright Reserved

Trading Lead

Leputech HPLC Laboratory