MSDS# 2044-A
Product Code: Q.QS05, Q.QS16
Date of Preparation: 4/05/00 Rev. A
Material Safety Data Sheet
SECTION 1 IDENTIFICATION
Product Name: QWIK SHOT? Manufacturer:
Intercontinental Lubricants Corp./
Spectro Oils of America
993 Federal Road
Brookfield, CT 06804
(203) 775-1291 Fax: (203) 775-8720
MSDS Date of Preparation: 4/05/2000
SECTION 2 PRODUCT COMPONENTS
INGREDIENTS CAS#. WT.% EXPOSURE LIMITS .
No hazardous Ingredients
SECTION 3: HAZARDS IDENTIFICATION
EMERGENCY OVERVIEW
This product is an opaque liquid with a lemon odor. May cause mild eye irritation.
HEALTH HAZARDS:
INHALATION: No adverse effects are expected from exposure.
SKIN CONTACT: No adverse effects are expected from exposure.
EYE CONTACT: May cause mild irritation.
INGESTION: No adverse effects expected from exposure.
CHRONIC EFFECTS OF OVEREXPOSURE: No adverse effects expected from exposure.
CARCINOGENICITY: None of the components of this product persent at greater than 0.1% are listed as a carcinogen or
suspected carcinogen by IARC, NTP or OSHA.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE: None expected.
SECTION 4 EMERGENCY and FIRST AID PROCEDURES
EYE CONTACT: Immediately flush eye with water for at least 15 minutes while lifting the upper and lower lids. Get
medical attention.
SKIN CONTACT: Wash skin with soap and water.
INHALATION: Remove victim to fresh air.
INGESTION: Get immediate medical attention by calling a Poison Control Center or hospital emergency department.
SECTION 5 FIRE and EXPLOSION HAZARD DATA
FLASH POINT: None (TCC)
METHOD: TCC
SECTION 5 FIRE and EXPLOSION HAZARD DATA (continued)
Page 1 of 1
MSDS# 2044-A
Product Code: Q.QS05, Q.QS16
Date of Preparation: 4/05/00 Rev. A
FLAMMABLE LIMITS: (vol % in air) Not determined
AUTOIGNITION TEMPERATURE: Not established
EXTINGUISHING MEDIA: Use media appropriate for surrounding fire.
SPECIAL FIREFIGHTING PROCEDURES: Firefighters should wear full emergency equipment and NIOSH approved
positive pressure self-contained breathing apparatus. Cool exposed intact containers with water spray or stream.
UNUSUAL FIRE AND EXPLOSION HAZARDS: None
SECTION 6 ACCIDENTAL RELEASE MEASURES
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED: Wear appropriate protective equipment.
Collect material for disposal using an absorbent material and place in a suitable container.
SECTION 7 HANDLING and STORAGE
Avoid eye and prolonged/repeated skin contact. Wash thoroughly after handling. Keep container closed. Keep out of
reach of children.
Protect containers from physical damage. Store in a cool area away from oxidizers.
Empty containers retain product residues. Do not cut, weld, braze, etc. on or near empty containers. Follow all MSDS
precautions in handling empty containers.
SECTION 8 EXPOSURE CONTROLS and PERSONAL PROTECTION
RESPIRATORY PROTECTION: None needed under normal use conditions with adequate ventilation.
VENTILATION: Good general room ventilation (equivalent to outdoors) should be adequate under normal conditions. If
the recommended exposure limit is exceeded increased mechanical ventilation such as local exhaust may be required.
GLOVES: None needed under normal use conditions.
EYE PROTECTION: Safety glasses recommended.
OTHER PROTECTIVE EQUIPMENT: None needed under normal use conditions. Suitable washing facilities should be
available.
SECTION 9 PHYSICAL and CHEMICAL PROPERTIES
BOILING POINT (@ 760 mmHg): ~212癋 MELTING POINT: Not available
SPECIFIC GRAVITY (H2O=1): 1.020 VOLATILE: Not available
VAPOR PRESSURE (@ 20 C mm Hg): ~18 (VAPOR DENSITY (AIR=1): ~1
EVAPORATION RATE : ): :~1 COEFFICIENT OF WATER/OIL: Not available
APPEARANCE AND ODOR: Opaque liquid with a lemon odor.
SECTION 10 STABILITY and REACTIVITY
STABILITY: This material is stable.
CONDITIONS TO AVOID: None.
INCOMPATIBILITY: Avoid strong oxidizers.
HAZARDOUS DECOMPOSITION PRODUCTS: Thermal decomposition may yield carbon monoxide and carbon dioxide.
HAZARDOUS POLYMERIZATION: Will not occur.
SECTION 11 TOXICOLOGICAL INFORMATION
Page 2 of 2
MSDS# 2044-A
Product Code: Q.QS05, Q.QS16
Date of Preparation: 4/05/00 Rev. A
ACUTE TOXICITY VALUES: Product: No data available
None of the components present at greater than 0.1% are listed as a carcinogen or suspect carcinogen by NTP, IARC or
OSHA.
None of the components have been found to be mutagenic.
None of the components are known to cause sensitization in animals or humans.
None of the components are known to cause adverse reproductive effects or teratogenic effects in animals or humans.
SECTION 12: ECOLOGICAL INFORMATION
There is no ecotoxicity data available for this product at this time.
SECTION 13: DISPOSAL INFORMATION
WASTE DISPOSAL METHOD: Dispose in accordance with all local, state and federal regulations.
SECTION 14: TRANSPORTATION INFORMATION
DOT SHIPPING DESCRIPTION: Not Regulated
DOT HAZARD CLASSIFICATION: None
DOT LABELS REQUIRED (49CFR172.101): None
UN NUMBER: None
SECTION 15: REGULATORY INFORMATION
OSHA HAZARD CLASSIFICATION: Not Hazardous
EPA SARA 302: This product does not contain chemicals regulated under SARA Section 302.
EPA SARA 311 HAZARD CLASSIFICATION: Not Hazardous.
EPA SARA 313: This product contains the following chemicals that are regulated under SARA Title III, section 313:
None
WHMIS CLASSIFICATION: Not a controlled product.
This product has been classified in accordance with the hazard criteria in the CPR and the MSDS contains all the
information required by the CPR.
EU CLASSIFICATION: Not a dangerous preparation.
EU RISK AND SAFETY PHRASES: None
TOXIC SUBSTANCES CONTROL ACT: All of the components of this product are listed on the TSCA inventory.
CANADA: All of the components of this product are listed on the Canadian Domestic Substances List (DSL).
CALIFORNIA PROPOSITION 65: This product contain the following chemicals which are known to the State of California
to cause cancer:
Ethylene Oxide 75-21-3 <0.000002%
1,4-Dioxane 123-91-1 <0.0000015%
Acetaldehyde 75-07-0 <0.0000006%
Formaldehyde 50-00-0 <0.0000004%