TECHNICAL BULLETIN:
Colloidal Silver Shaft Coating PN: CS015

Application: Used to enhance shaft surface
conductivity for use with AEGIS
Bearing Protection Ring Technology

Background: Maintaining a conductive shaft surface is
required to allow efficient discharge of VFD induced shaft
voltage to the AEGIS Bearing Protection Ring micro fibers
(also known as the AEGIS Shaft Grounding Ring). Our
AEGIS micro fiber shaft grounding technology was designed to discharge voltages by applying a
circumferential ring of conductive micro fibers directly to the steel shaft surface in VFD driven
electric motors.

Shaft surface conductivity: Improving the conductivity of the steel shaft surface enhances the
shaft voltage discharge capability in AEGIS shaft grounding applications. Maintaining a highly
conductive shaft surface is especially important in critical applications or in applications where
the conductive shaft surface of steel could become compromised. Environmental elements
could create a potential for decreased conductivity on the shaft of the motor.

Test results: Applying Colloidal Silver Shaft Coating to the shaft surface before AEGIS is
installed significantly increased the surface conductivity of the shaft and decreased the residual
voltage level measured on the shaft. The Colloidal Silver Shaft Coating increases the
conductivity between the motor shaft and the AEGIS conductive microfibers.

Recommendation: Apply AEGIS CS015 Colloidal Silver Shaft Coating to any VFD driven motor
shaft prior to installing AEGIS Bearing Protection RingTM. Treating the shaft of the motor prior
to installing AEGIS shaft grounding ring technology is a low cost performance enhancement
option.




AEGIS SGRTM Prevents Electrical Bearing Damage
31 Winterbrook Road
Mechanic Falls, ME 04256-5724
Toll free: 1-866-738-1857
Ph: 207-998-5140
Fax: 207-998-5143
sales@est-aegis.com
www.est-aegis.com




Application Notes for Part Number CS015:
Thoroughly stir the silver coating.

Shaft must be clean & free of any coatings, paint, or other nonconductive material. The

shaft must be clean to bare metal. Depending on the condition of the shaft, it may
require using emery cloth or Scotch-Brite. If the shaft is visibly clean, a non petroleum
based solvent may be used to remove any residue. If possible, check the conductivity of
the shaft using an ohms meter.
Ohms test: Place the positive and negative meter leads on the shaft at a place
o
where the microfibers will contact the shaft. Each motor will have a different
reading but in general you should have a maximum reading of 2 ohms. If the
reading is higher, clean the shaft again and retest.
Apply a light coat of the AEGIS Colloidal Silver Shaft Coating to the area where the

AEGIS microfibers are in contact with the motor shaft. Apply evenly all around the
shaft.
Allow to dry before installing the AEGIS Shaft Grounding Ring. Coating will cure at room

temperature in 16-20 hours or in 30 minutes at 120-200癈. A heat gun will cure the
materials in seconds.

Shelf Life: 6 months; material should be jar rolled at 1-6 rev/hr. Avoid exposure to extreme
temperatures.
Storage: Store in a dry location at 5-30癈. Allow paint to come to room temperature prior
to opening.

Refer to the Material Safety Data Sheet for additional information.



Best regards,

Adam Willwerth
AEGIS Sales/Marketing Manager




AEGIS SGRTM Prevents Electrical Bearing Damage
31 Winterbrook Road
Mechanic Falls, ME 04256-5724
Toll free: 1-866-738-1857
Ph: 207-998-5140
Fax: 207-998-5143
sales@est-aegis.com
www.est-aegis.com




Material Safety Data Sheet:

Colloidal Silver Shaft Coating Product Number: CS015
Issue Date (03-13-07)
Review Date (03-22-07)

Section 1: Product and Company Identification
Product Name: Colloidal Silver Shaft Coating
Manufactured for: Electro Static Technology-ITW, 31 Winterbrook Road, Mechanic Falls, ME 04256
Ph: 207-998-5140 Fx: 207-998-5143 www.est-aegis.com
Chemtrec Emergency Number 1-800-424-9300 24 hrs a day.

Section 2: Composition / Information on Ingredients

Principle Hazardous % OSHA ACGIH NTP IARC OSHA
Component(s) PEL TLV regulated
(chemical and common name(s)) mg/m3 mg/m3
(Cas. No)
Silver (7440-22-4)* ~60 0.01 0.1 No No No
Arcosolve PM (107-98-2) 100 PPM ND No No No
Toluene (108-88-3) 10 100 PPM ND No 3 No
Ethanol (64-17-5) 1000 PPM ND No No No
Ethyl Acetate (141-78-6) 4 400 PPM ND No No No
*NIOSH IDLH: 10 mg/m (as Ag) 0.1 mg/m3
3



Section 3: Hazard Identification
Emergency overview
Appearance: Gray liquid or paste
Immediate effects: Flammable material. Caution! May cause skin irritation.
Potential health effects
Primary routes of entry: Inhalation, ingestion, skin, and eye contact.
Signs and Symptoms of Overexposure: ND
Eyes: May cause eye irritation.
Skin: May cause skin irritation.
Ingestion: NIF
Inhalation: NIF
Chronic Exposure: NIF
Chemical Listed As Carcinogen or Potential Carcinogen: No
See Toxicological Information (Section 11)
Potential environmental effects
See Ecological Information (Section 12)


Page 1
31 Winterbrook Road
Mechanic Falls, ME 04256-5724
Toll free: 1-866-738-1857
Ph: 207-998-5140
Fax: 207-998-5143
sales@est-aegis.com
www.est-aegis.com



Section 4: First Aid Measures
If accidental overexposure is suspected
Eye(s) Contact: Flush immediately with large amounts of water for at least 15 minutes. Eyelids should be
held away from the eyeball to ensure thorough rinsing. Get medical attention if irritation persists.
Skin Contact: Wash area thoroughly with soap and water. Get medical aid if irritation develops or persist.
Inhalation: Remove from exposure to fresh air immediately. Get medical aid if cough or other symptoms
appear.
Ingestion: Do not induce vomiting. Never give anything by mouth to an unconscious person. If victim is
conscious and alert, give 2-4 cups full of milk or water. Get medical aid.
Note to physician
Treatment: ND
Medical Conditions generally Aggravated by Exposure: ND

Section 5: Fire Fighting Measures
Flash Point: 24?F (Ethyl Acetate).
Flammable Limits: ND
Auto-ignition point: ND
Fire Extinguishing Media: Carbon dioxide, foam, dry chemical, water
Special Fire Fighting Procedures: As in any fire, wear self-contained breathing apparatus pressure-
demand, (MSHA/NIOSH approved or equivalent) and full protective gear.
Unusual Fire and Explosion Hazards: Can burn in fire, releasing toxic vapors. Vaporized easily at normal
temperatures.
Hazardous combustion products: Forms carbon dioxide and carbon monoxide.
DOT Class: Flammable

Section 6: Accidental Release Measures
Steps to be Taken in Case Material is Released or Spilled: Wear protective equipment. For an
uncontrolled release of this product to the environment, take immediate steps to stop and contain
release. Notify local authorities, if required. Clean up with rags or paper and place in container for
refining.
Waste Disposal Methods: Dispose of waste according to Federal, State and Local Regulations.

Section 7: Handling and Storage
Precautions to be Taken in Handling and Storage: Used with adequate ventilation. Avoid contact with skin
and eyes. Wash thoroughly after handling. Keep container closed when not in use.
Storage temperature: Store at ambient or lower temperature.
Storage Pressure: NA

Section 8: Exposure Controls / Personal Protection
Engineering Controls
Ventilation required: Use adequate general or local exhaust ventilation to keep airborne concentrations
below the permissible exposure limits.
Personal Protection Equipment
Respiratory protection: Good general ventilation should be sufficient to control airborne levels. A NIOSH
approved dust/mist respirator is recommended when TLV levels are exceeded.
Protective gloves: Use appropriate chemical gloves when handling.
Skin protection: Use appropriate protective clothing, gloves and shoes.
Eye protection: Wear chemical safety glasses with side shields or face shield


Page 2
31 Winterbrook Road
Mechanic Falls, ME 04256-5724
Toll free: 1-866-738-1857
Ph: 207-998-5140
Fax: 207-998-5143
sales@est-aegis.com
www.est-aegis.com

Additional clothing and/or equipment: Eye wash facilities available where eye contact can occur.
Exposure Guidelines
See Composition/Information on Ingredients (Section2)

Section 9 Physical and Chemical Properties
Appearance and Physical State: Grey paste liquid.
Odor (threshold): Strong odor
Specific Gravity (H2O=1): ND
Vapor Pressure (mm Hg): ND
Vapor Density (air=1): ND
Percent Volatile by volume: ND

Evaporation Rate (butyl acetate=1): ND
Boiling Point: 167?F
Freezing point / melting point: ND
pH: NA
Solubility in Water: ND
Molecular Weight: NA

Section 10: Stability and Reactivity
Stability: Stable under normal conditions of use. Keep cap tight.
Conditions to Avoid: Incompatible materials
Materials to Avoid (Incompatibility): Strong oxidizers, acids and alkali.
Hazardous Decomposition Products: Carbon dioxide and carbon monoxide
Hazardous Polymerization: Will not occur.

Section 11: Toxicological Information
Results of component toxicity test performed: ND
Human experience: ND
This product does not contain any compounds listed by NTP or IARC or regulated by OSHA as a
carcinogen.

Section 12: Ecological Information
Ecological Information: Ecological data are not available. Material should be treated as harmful to aquatic
organisms.
Chemical Fate Information: ND

Section 13 Disposal Considerations
RCRA 40 CFR 261 Classification: Can be recycled to recover precious metal.
Federal, State and local laws governing disposal of materials can differ. Ensure proper disposal
compliance with proper authorities before disposal.

Section 14: Transportation Information
US DOT Information: Proper shipping name: Flammable liquid, n.o.s. (1-Methyoxy-2-Propanol, Toluene)
Hazard Class: 3
Packaging group: III
UN Number: UN1993
IATA: Proper shipping name: Flammable liquid, n.o.s. (1-Methyoxy-2-Propanol, Toluene)
Hazard Class: 3



Page 3
31 Winterbrook Road
Mechanic Falls, ME 04256-5724
Toll free: 1-866-738-1857
Ph: 207-998-5140
Fax: 207-998-5143
sales@est-aegis.com
www.est-aegis.com

Packing group: III
UN Number: UN1993
IMO: Proper shipping name: Flammable liquid, n.o.s. (1-Methyoxy-2-Propanol, Toluene)
Class: 3
UN Number: UN1993
Packing group: III
Marine Pollutant: No
Canadian TDG: Flammable liquid, n.o.s. (1-Methyoxy-2-Propanol, Toluene)

Section 15: Regulatory Information
United States Federal Regulations
MSDS complies with OSHA's Hazard Communication Rule 29, CFR 1910.1200.
SARA:
SARA Title III: Following ingredients of this product are listed in SARA 313: Toluene: CAS# 108-88-3, 10%
Maximum Ethyl Acetate: CAS# 141-78-6, 4% Maximum.
Silver: CAS# 7440-22-4, 60% Maximum.
RCRA: ND
TSCA: All components of this product are listed on the TSCA Inventory.
CERCLA: Toluene: RQ = 1000 lbs (45.4 Kg), Silver: RQ = 1000 lbs (45.4 Kg), Ethyl Acetate: RQ = 5000
lbs (2270 Kg)
State Regulations
California Proposition 65: Contains Toluene and Ethanol. These chemicals are known to the State of
California to cause birth defects or other reproductive harm.
International Regulations
Canada WHMIS: ND
Europe EINECS Numbers: ND

Section 16: Other Information
Label Information: ND
European Risk and Safety Phrases: ND
European symbols needed: ND
Canadian WHMIS Symbols: ND
Hazard Rating HMIS? Health: 2; Fire: 3; Reactivity: 0; Personal Protection Equip.: B
NFPA Ratings: ND
(0=least, 1=Slight, 2=Moderate, 3=High, 4=Extreme)
Abbreviations used in this document
NE= Not established
NA= Not applicable
NIF= No Information Found
ND= No Data
Disclaimer
Electro Static Technology-ITW makes no warranty of any kind regarding the information furnished herein.
Users should independently determine the suitability and completeness of information from all sources.
While this data is presented in good faith and believed to be accurate, it should be considered only as a
supplement to other information gathered by the user. It is the User's responsibility to assure the proper
use and disposal of these materials as well as the safety and health of all personnel who may work with
or otherwise come in contact with these materials.

MSDS Form 001CS015 V1



Page 4

Search    ENTER KEYWORD
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
107-98-2_108-32.asp 107-98-2 108-32-7
7732-18-5_7722-84-1_107-98-2_75-21.asp 7732-18-5 7722-84-1 107-98-2 75-21-8
1333-86-4_2786-76-7_15793-73-4_111-76-2_822-06-0_2807-30-9_51274-00.asp 1333-86-4 2786-76-7 15793-73-4 111-76-2 822-06-0 2807-30-9 51274-00-1 12225-18-2 147-14-8 28182-81-2 21645-51-2 7631-86-9 7727-43-7 68551-65-5 107-98-2 1047-16-1 13463-67-7 7732-18-5
68476-86-8_107-98-2_7732-18-5.asp 68476-86-8 107-98-2 7732-18-5
107-98-2_109-86-4_100-51-6_108-94-1_68410-23-1_7440-47-3_2210-79.asp 107-98-2 109-86-4 100-51-6 108-94-1 68410-23-1 7440-47-3 2210-79-9
9016-45-9_7320-34-5_25155-30-0_68130-47-2_34590-94-8_111-77.asp 9016-45-9 7320-34-5 25155-30-0 68130-47-2 34590-94-8 111-77-3 107-98-2 6834-92-0
123-86-4_10-66-6_108-65-6_107-98-2_64742-95-6_123-42-2_95-63.asp 123-86-4 10-66-6 108-65-6 107-98-2 64742-95-6 123-42-2 95-63-6 10-20-3 108-67-8 10-37-5 98-82-8
107-98-2.asp 107-98-2
98-82-8_95-63-6_108-67-8_1330-20-7_64742-95-6_107-98-2.asp 98-82-8 95-63-6 108-67-8 1330-20-7 64742-95-6 107-98-2
107-98-2_111-76-2_1589-47-5_7732-18.asp 107-98-2 111-76-2 1589-47-5 7732-18-5
107-98-2_78-93-3_1589-47.asp 107-98-2 78-93-3 1589-47-5
77182-82-2_32612-48-9_107-98.asp 77182-82-2 32612-48-9 107-98-2
25036-25-3_107-98-2_34590-94-8_1330-20-7_100-41-4_67-56.asp 25036-25-3 107-98-2 34590-94-8 1330-20-7 100-41-4 67-56-1
107-98-2_66455-14-9_67-63-0_34395-72-7_1300-72-7.asp 107-98-2 66455-14-9 67-63-0 34395-72-7 1300-72-7
107-98-2_64-17-5.asp 107-98-2 64-17-5
107-98-2_67-63-0.asp 107-98-2 67-63-0
1333-86-4_107-98-2.asp 1333-86-4 107-98-2
100-41-4_107-98-2_108-65-6_108-88-3_110-43-0_112-07-2_25068-38.asp 100-41-4 107-98-2 108-65-6 108-88-3 110-43-0 112-07-2 25068-38-6 50-00-0 71-36-3 7429-90-5 8052-41-3
107-98-2.asp 107-98-2
7732-18-5_111-76-2_107-98-2_137-16-6_142-87.asp 7732-18-5 111-76-2 107-98-2 137-16-6 142-87-0
107-98-2_111-76-2_872-50-4.asp 107-98-2 111-76-2 872-50-4
107-98-2_1333-86-4.asp 107-98-2 1333-86-4
107-98-2_69011-36-5_10-10.asp 107-98-2 69011-36-5 10-10-2
1330-20-7_025068-38-6_108-88-3_78-93-3_107-98-2_64742-95.asp 1330-20-7 025068-38-6 108-88-3 78-93-3 107-98-2 64742-95-6
1333-86-4_2807-30-9_107-98-2_7732-18.asp 1333-86-4 2807-30-9 107-98-2 7732-18-5
1330-20-7_107-98-2.asp 1330-20-7 107-98-2
67-63-0_107-98-2.asp 67-63-0 107-98-2
107-98-2.asp 107-98-2
107-98.asp 107-98-2
123-86-4_10-66-6_108-65-6_108-88-3_38-48-6_67-64-1_11-36-6_107-98.asp 123-86-4 10-66-6 108-65-6 108-88-3 38-48-6 67-64-1 11-36-6 107-98-2
107-98-2_111-76-2_7732-18-5_1589-47-5_107-21.asp 107-98-2 111-76-2 7732-18-5 1589-47-5 107-21-1
294-36-8_78-93-3_67-56-1_107-98.asp 294-36-8 78-93-3 67-56-1 107-98-2
111-90-0_107-98-2_9046-10.asp 111-90-0 107-98-2 9046-10-0
107-98-2.asp 107-98-2
107-98-2_7732-18-5_141-43-5_68478-65-9_67-63-0_27176-87-0_1559-35.asp 107-98-2 7732-18-5 141-43-5 68478-65-9 67-63-0 27176-87-0 1559-35-9 1589-47-5 1559-36-0
7732-18-5_34590-94-8_107-98.asp 7732-18-5 34590-94-8 107-98-2
03-13-0_03-22-0_7440-22-4_107-98-2_108-88-3_64-17-5_141-78.asp 03-13-0 03-22-0 7440-22-4 107-98-2 108-88-3 64-17-5 141-78-6
34590-94-8_111-76-2_107-98-2.asp 34590-94-8 111-76-2 107-98-2
34590-94-8_107-98-2_111-41.asp 34590-94-8 107-98-2 111-41-1
107-98-2_108-65-6.asp 107-98-2 108-65-6
107-98-2_25068-38-6_100-51-6_7732-18-5.asp 107-98-2 25068-38-6 100-51-6 7732-18-5
107-98-2_68-12-2_78-93-3_78-59-1_541-85.asp 107-98-2 68-12-2 78-93-3 78-59-1 541-85-5
14808-60-7_1314-13-2_107-98-2_26530-20-1.asp 14808-60-7 1314-13-2 107-98-2 26530-20-1
7779-90-0_14807-96-6_108-10-1_107-98-2_1330-20-7_68855-54.asp 7779-90-0 14807-96-6 108-10-1 107-98-2 1330-20-7 68855-54-9 60580-61-2
108-65-6_108-94-1_107-98.asp 108-65-6 108-94-1 107-98-2
107-98-2_1569-02-4_7732-18.asp 107-98-2 1569-02-4 7732-18-5
107-98-2_64-17-5_1589-47-5_67-63-0_141-78.asp 107-98-2 64-17-5 1589-47-5 67-63-0 141-78-6
25068-38-6_1330-20-7_78-83-1_100-41-4_107-98.asp 25068-38-6 1330-20-7 78-83-1 100-41-4 107-98-2
9016-45-9_68081-81-2_68130-47-2_34590-94-8_111-77-3_107-98.asp 9016-45-9 68081-81-2 68130-47-2 34590-94-8 111-77-3 107-98-2 7320-34-5 6834-92-0
57472-68-1_13048-33-4_25584-83-2_15625-89-5_52408-84-1_28961-43.asp 57472-68-1 13048-33-4 25584-83-2 15625-89-5 52408-84-1 28961-43-5 53879-54-2 27306-39-4 25035-69-2 64-17-5 78-83-1 67-63-0 71-23-8 126-86-3 123-86-4 141-78-6 109-60-4 61790-31-6 7664-41-7 1336-21-6 112-84-5 141-43-5 57-13-6 84-61-7 10287-53-5 119313-12-1 947-19-3 7473-98-5 5495-84-1 83846-86-0 71868-10-5 68131-40-8 112-34-5 9014-85-1 111-90-0 25322-68-3 64742-47-8 64741-89-5


HBCChem,Inc

Chemical Information Net chemcas.orgCopyright Reserved

Trading Lead

Leputech HPLC Laboratory