KLEEN-FLO TUMBLER INDUSTRIES LIMITED MATERIAL SAFETY DATA SHEET PAGE 1
SECTION I-MATERIAL IDENTIFICATION AND USE
Material Name/Identifier: Rim Slip Tire Mounting Lube Stock No. 571/572
Manufacturer's Name: Kleen-Flo Tumbler Industries Ltd Street Address: 75 Advance Blvd.
City: Brampton Province: Ontario
Postal Code: L6T 4N1 Emergency Phone #: (905) 793-4311
Chemical Name: N. Ap (Mixture) Chemical Family: N. Ap (Mixture)
Chemical Formula: N. Ap (Mixture) Trade name & Synonysms: None
Material Use: Tire Lubricant Molecular Weight: N. Ap (Mixture)
Physical State: liquid Odour/Appearance: odourless/Light yellow -green fluid
Specific Gravity: 1.005 Odour Threshold(p.p.m.): N/E
Boiling Point: N/E Evaporation Rate: N/E
Freezing Point: N/E Solubility in Water: Soluble in all proportion.
% Volatile(by volume): > 80% Vapour Pressure(mm)Hg: N/E
Vapour Density(Air=1): N/E Coefficient of Water/Oil Distribut: N/E
pH 10 - 11
SECTION IV-FIRE AND EXPLOSION HAZARD OF MATERIAL
Flammability Yes/No No If yes under which conditions: N.Ap.
Auto Ignition Temperature: N/E Means of Extinction: Waterspray, dry chemical, carbon dioxide foam,
Flashpoint and Method: None Hazardous Combustion Products: Carbon monoxide,
Special fire fighting procedure None required carbon dioxide, chloride or phosgene
Upper Flammable limit N.Ap. Lower Flammable Limit(% by volume): N.Ap.
Explosion Data: Sensitivity to mechanical impact : No Sensitivity to Static Discharge: No
SECTION V-REACTIVITY DATA
Chemical Stability Yes/No: Yes If NO under which conditions? N.Ap.
Incompatibility to Other Substances Yes/No: Yes If so which ones? Strong oxidizers
Reactivity and under what conditions? Open flame and welding arcs can cause small amounts of phosgene & chlorine fumes.
Hazardous Decomposition Products: Carbon monoxide, carbon dioxide and other unknown combustible materials.
Hazardous polymerization: None known
N/E: not established N.Ap.: not applicable N/Av.: not available
Material Name/Identifier: Rim Slip Tire Mounting Lube Stock No. 571/572 PAGE 2
SECTION VI-TOXICOLOGICAL PROPERTIES OF PRODUCT
Route of Entry: --SKIN CONTACT -xSKIN ABSORPTION -xEYE CONTACT -xINHALATION -xINGESTION
Effects of Acute Exposure: Prolonged or repeated contact with skin may cause damage to kidneys and depression of the central nervous
central nervous system due to ethylene glycol. A mouthful ingested would have no toxic effect.
Effects of Chronic Exposure: N/E
LD 50 of Product N/E LC 50 of Product N/E
Irritancy of Product: Mild eye irritant(no permanent damage) Exposure Limits of Product: N/E
Sensitization of Product: None Known Toxicologically Synergistic Materials: N/A
--CARCINOGENICITY --REPRODUCTIVE EFFECTS --TERATOGENICITY --MUTAGENICITY None known
SECTION VII-PREVENTIVE MEASURES
Personal Protective Equipment to be used:
Gloves(specify): Polyethylene type Eye(specify): Glass goggles
Respiratory(specify): Not required Clothing: plastic apron. Footwear: Not required
Respiratory Protection: If used indoors or on a continuous basis, use of cartridge type respirator is recommended
Engineering Controls: Local or mechanical exhaust recommended.
Leak and Spill Procedure: Hose off with plenty of water. Soak area for 10 to 20 minutes. Repeat if necessary.
Waste Disposal: Contain into waste container or absorb with non-combustible absorbent material.
Storage Requirements: Keep container closed when not in use.
Handling Procedures and
Equipment: Avoid skin and prolonged inhalation contact.
DSL listing All components are listed in the inventory.
TDG Classification: Not regulated
WHMIS Classification: #571: Consumer Commodity # 572 D2B
SECTION VIII-FIRST AID MEASURES
Eye: Rinse with plenty of water for 15 minutes. If discomfort persists, consult a doctor.
Skin: Remove contaminated clothing. Wash with soap and water. If rash persists, seek medical help.
Inhalation: Remove to fresh air
Ingestion: Give two glasses of milk. INDUCE VOMITING. Seek medical attention.
SECTION IX-PREPARATION DATE OF M.S.D.S.
Additional Info/Comments: Sources Used: Supplier's data
Phone Number: (905) 793-4311 Prepared By: Quality Control Laboratory
Date prepared: January 2,2009. Kleen-Flo Tumbler Industries Limited
THIS SHEET SUPERSEDES ANY OTHER M.S.D.S. PREVIOUSLY PREPARED
N/Av.: not available N/Ap.: not applicable N/E: not established