232376 E. Pacifica Place Rancho Dominguez, CA 90220 (800) 675-1118 www.alliedhightech.com
MATERIAL/CHEMICAL SAFETY DATA SHEET
SECTION 3: HAZARDS IDENTIFICATION
SECTION 1: CHEMICAL PRODUCT & COMPANY IDENTIFICATION
Hazard Statement: Gross overexposure by inhalation may cause suffocation if air is
Product Details displaced by vapors and central nervous system stimulation with increased activity or sleeplesness
tremors or convulsions. These effects may be followed by central nervous system depression with
Silicone Cold Mold Release
Product Name: dizziness, confusion, incoordination, drowsiness or unconsciousness. May cause irregular
- Liquid heartbeat, "heart thumping", apprehension, lightheadedness, feeling faint, weak, sometimes
progressing to loss of consciousness and death. Intentional misuse or deliberate inhalation may
cause death without warning. Vapor reduces oxygen available for breathing and is heavier than air.
200-10015
Allied Item No.: Major ingestion hazard is aspiration (liquid entering the lungs) which may result in "chemical
pneumonia". Symptoms include coughing, gasping, choking, shortness of breath, bluish
discoloration in skin, rapid breathing and heart rate and fever. Pulmonary edema or bleeding,
drowsiness, confusion, coma and seizures may occur in serious cases. Pre-existing disease of the
central nervous system or cardiovascular system will increase susceptibility. Ingestion may cause
Chemical Name: Dry Lubricant Release Agent pathological changes in liver, central nervous system or heart muscle tissue.
SECTION 4: FIRST AID MEASURES
Company Identification Potential First Aid/
Health Effects Medical Info.
Allied High Tech Products, Inc.
Eye Contact: May cause irritation with Flush with water, lifting
2376 East Pacifica Place
discomfort, tearing or eyelids occasionally until
Rancho Dominguez, CA 90220 blurring of vision. Liquid no evidence of the
(310) 635-2466 will irritate eyes and may chemical remains. Get
cause conjunctivitis. medical attention.
Contact Point
Transportation for United States
Skin Contact: May cause irritation with Wash with soap and
Chemtrec (800) 424-9300 * (202) 483-7616
itching, redness or water. Get medical
swelling. attention if irritation
SECTION 2: COMPOSITION/INFORMATION ON INGREDIENT persists.
Exposure Limits in Air Carcin.
Chemical Name CAS No. ACGIH TLV or TWA OSHA PEL Y/N
Inhalation: Remove to fresh air
See hazard statement
2,3-Dihydrodeca- 138495-42-8 NE NE N
immediately. Keep person
above. DO NOT INHALE
fluoropentane 23-
calm. If not breathing, give
THIS PRODUCT!
28%
CPR. If breathing is difficult,
give oxygen. Seek medical
1,1,1,3,3-Penta- 406-58-6 NE NE N
attention immediately.
fluorobutane 32-38%
Ingestion: See hazard statement DO NOT induce vomiting
Trans, 1,2-Dichloro- 156-60-5 200 ppm 200 ppm N above. DO NOT INGEST unless instructed by
ethylene 32-38% THIS PRODUCT! physician. DO NOT give
stimulants. Take immedi-
Tetrafluoroethylene ately to a hospital or
Telomer 1-5% 65530-85-0 NE NE N physician.
9002-84-0
Note: Because of possible disturbance of cardiac rhythm, catechola-
mine drugs, such as adrenaline or epinephrine should be
reserved for emergencies and then used only with special
caution.
SECTION 5: FIRE FIGHTING MEASURES
Extinguishing Media: Use media appropriate for surrounding material.
Fire Fighting Instruction: Wear full protective clothing and OSHA/NIOSH
self-contained breathing apparatus with full facepiece. Water may be
used to cool containers and reduce pressure.
Special Hazards: Use water spray or fog to cool containers. Drums
may rupture under fire conditions. Decomposition may occur.
SECTION 6: ACCIDENTAL RELEASE MEASURES
Review Section 6 before proceeding with clean up. Remove any
ignition sources. Ventilate area, especially low places where heavy
vapors might collect. Contain liquid, soak up with sawdust, sand or
HMIS Ratings other absorbent material. Do not flush to sewer. Composition of
Ingredients are listed on the TSCA Inventory of
Health: vapors above the liquid may fall within the LEL/UEL and become
1
Chemical Substances.
flammable. Transfer to properly labeled closed metal containers.
Flammability: 1
Those not identified are non-hazardous.
Reactivity: 1
Page 1 of 2:
2376 E. Pacifica Place ?Rancho Dominguez, CA 90220 ?(800) 675-1118 ?www.alliedhightech.com
SECTION 7: HANDLING & STORAGE SECTION 12: ECOLOGICAL INFORMATION
Handling: Observe good housekeeping practices. NA
Storage: Store in a clean dry area. Do not heat above
125 癋 (52 癈). Do not store or consume food, drink
or tobacco in areas where they may become contami-
nated with this material. Rotate stock to shelf life of
one year.
SECTION 8: EXPOSURE CONTROL & PERSONAL PROTECTION SECTION 13: DISPOSAL INFORMATION
Engineering Measures: Use with sufficient ventilation to keep employee exposure below the
Dispose of waste material according to Federal,
recommended exposure limit, especially in enclosed and low places. Mechanical ventilation should
State and Local regulations. Do not puncture or
be used in low or enclosed places.
incinerate containers.
Respiratory Protection: Use OSHA/NIOSH approved respiratory protection if level of air
contaminants is excessive.
Protective Gloves: Use impervious gloves.
Eye Protection: Safety glasses or chemical splash goggles.
Other: Eyewash, safety shower and impervious clothing are recommended.
SECTION 9: PHYSICAL & CHEMICAL PROPERTIES SECTION 14: TRANSPORT INFORMATION
Appearance: Milky white liquid Not regulated.
Odor: Ethereal odor
Solubility: NA
Boiling Point: 97 癋 (36 癈)
Melting Point: NA
Flash Point: NA
Vapor Pressure: 497 mmHg@ 77 癋 (25 癈)
Vapor Density: NA
Evaporation Rate: NA
SECTION 15: REGULATORY INFORMATION
pH Information: 7
Flammable Limits LEL: 6
Toxic Substance Control Act TSCA: All ingredients are TSCA listed.
Flammable Limits UEL: 12
VOC Content: 97% CERCLA: Trans,1,2-dichloroethylene component only is classified as
a hazardous substance.
SECTION 10: STABILITY & REACTIVITY
SARA Title III: This product is categorized as an Acute Health risk.
Conditions to Avoid/Incompatibles: Alkalis, or alkaline earth metals, powdered Al,
Na, Mg, Zn, Be, etc. and strong bases such as NaOH, KOH, etc.
Decomposition Products: This product can be decomposed by high temperatures
(flame, glowing metal surfaces, etc.) forming hydrochloric and hydrofluoric acids and
carbonyl fluoride and unsaturated compounds of unknown toxicity.
Hazardous Polymerization: Will not occur.
SECTION 16: OTHER INFORMATION
Legend
SECTION 11: TOXICOLOGICAL INFORMATION NAIF: No Applicable Information Found
NA: Not Available/Applicable
NA
NE: None Established
DISCLAIMER: The above information and recommendations are
believed accurate and reliable. Because it is not possible to anticipate
all conditions of use, additional safety precautions may be required.
ALLIED HIGH TECH PRODUCTS, INC. makes no warranty, either
express or implied, as to its accuracy or completeness and none is
made as to the fitness of this material for any purpose. The
manufacturer/distributor shall not be liable for damages to person or
property resulting from its use. Nothing herein shall be construed as a
recommendation for use in violation of any patent.
Page 2 of 2: Form Prepared By: Allied High Tech Products, Inc. January 2010
|