http://hazard.com/msds/f2/bsc/bsckg.html                                                    09/07/2005 09:50 AM



JOHNSON MATTHEY CATALOG CO -- WOODS METAL, 33218 -- 6810-00N044822
===================== Product Identification =====================

Product ID:WOODS METAL, 33218
MSDS Date:12/27/1988
FSC:6810
NIIN:00N044822
MSDS Number: BSCKG
=== Responsible Party ===
Company Name:JOHNSON MATTHEY CATALOG CO
Address:30 BOND ST
City:WARD HILL
State:MA
ZIP:01835-0747
Country:US
Info Phone Num:508-521-6300
Emergency Phone Num:508-521-6300;800-424-9300(CHEMTREC)
CAGE:0JVJ1
=== Contractor Identification ===
Company Name:JOHNSON MATTHEY CATALOG CO INC ALFA AESAR
Address:30 BOND ST
Box:City:WARD HILL
State:MA
ZIP:01835-0747
Country:US
Phone:978-521-6300
CAGE:0JVJ1

============= Composition/Information on Ingredients =============

Ingred Name:BISMUTH
CAS:7440-69-9
RTECS #:EB2600000
Fraction by Wt: 50%
OSHA PEL:N/K
ACGIH TLV:N/K

Ingred Name:LEAD
CAS:7439-92-1
RTECS #:OF7525000
Fraction by Wt: 25%
OSHA PEL:0.05 MG/M3
ACGIH TLV:0.15 MG/M3 DUST
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:TIN
CAS:7440-31-5
RTECS #:XP7320000
Fraction by Wt: 12.5%
OSHA PEL:2 MG/M3
ACGIH TLV:2 MG/M3

Ingred Name:CADMIUM
CAS:7440-43-9

http://hazard.com/msds/f2/bsc/bsckg.html Page 1 of 3
http://hazard.com/msds/f2/bsc/bsckg.html 09/07/2005 09:50 AM


RTECS #:EU9800000
Fraction by Wt: 12.5%
OSHA PEL:0.005 MG/M3 DUST
ACGIH TLV:0.05 MG/M3
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS

===================== Hazards Identification =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: INHALATION MAY CAUSE
IRRITATION. POISONING MAY OCCUR. CADMIUM MAY CAUSE CANCER. NOTE:
LEAD APPEARS ON NAVY LISTING OF OCCUPATIONAL CHEMICAL REPRODUCTIVE
HAZARDS. SEEK CONSULTATION FROM A PPROPRIATE HEALTH PROFESSIONALS
CONCERNING LATEST HAZARD LIST INFO & SAFE HANDLING & EXPOS INFO .
Explanation of Carcinogenicity:LEAD: IARC MONOGRAPHS, SUPPLEMENT, VOL
7, PG 230, 1987:GRP 2B. CADMIUM: IARC MONOGRAPHS, SUPPLEMENT, VOL
7, (SUPP DATA)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

======================= First Aid Measures =======================

First Aid:INHAL: REMOVE FROM EXPOSURE. EYES: FLUSH WITH COPIOUS AMOUNTS
OF WATER FOR AT LEAST 15 MINUTES. SKIN: REMOVE ANY CONTAMINATED
CLOTHING. FLOOD SKIN W/LG VOLUMES OF WATER FOR 15 MINUTES.
INGEST/INHAL: S EEK PROMPT, COMPETENT MEDICAL ATTENTION.

===================== Fire Fighting Measures =====================

Extinguishing Media:USE WATER, CARBON DIOXIDE, DRY CHEMICAL
EXTINGUISHING AGENTS, DRY SAND, OR DRY GROUND DOLOMITE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . IF W/OUT RISK, REMOVE MATERIAL FROM FIRE
AREA. COOL CONTRS W/WATER FROM MAXIMUM DISTANCE.
Unusual Fire/Explosion Hazard:MAY EMIT TOXIC FUME IF THERMALLY
DECOMPOSED.

================== Accidental Release Measures ==================

Spill Release Procedures:WEARING FULL PROTECTIVE CLOTHING AND
RESPIRATORY PROTECTION, ELIMINATE ALL SOURCES OF IGNITION. COVER
SPILL W/DRY SAND/DRY VERMICULITE, MIX WELL & CAREFULLY TRANSFER TO
A WELL-MARKED CONTAINER. CLOSE CONTAINER TIGHTLY. SUBMIT/RETAIN
FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

====================== Handling and Storage ======================

Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED. STORE
IN A COOL, DRY, WELL-VENTILATED AREA.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:NIOSH/MSHA APPROVED HIGH EFFICIENCY PARTICULATE
http://hazard.com/msds/f2/bsc/bsckg.html Page 2 of 3
http://hazard.com/msds/f2/bsc/bsckg.html 09/07/2005 09:50 AM


Respiratory Protection:NIOSH/MSHA APPROVED HIGH EFFICIENCY PARTICULATE
RESPIRATOR FOR ORDINARY USE AND SCBA FOR EMERGENCY USE.
Ventilation:LOC EXHAUST: ACCEPTABLE.
Protective Gloves:RUBBER.
Eye Protection:OSHA APPROVED SAFETY GOGGLES.
Other Protective Equipment:LAB COAT & APRON, FLAME & CHEM RESISTANT
COVERALLS, EYEWASH CAPABLE OF SUSTAINED FLUSHING, SFTY DRENCH (SUPP
DATA)
Work Hygienic Practices:WASH THOROUGHLY AFTER USE.
Supplemental Safety and Health
% VOLAT: NONVOLATILE. EXPLAN OF CARCIN: PG 139, 1987 GRP 2A. NTP 6TH
ANNUAL REPORT ON CARCINS, 1991: ANTIC TO BE CARCIN. CADMIUM: IARC
MONOGRAPHS, SUPPLEMENT, VOL 7, PG 139, 1987: GRP 2A. NTP 6TH ANNU
AL REPORT ON CARCIN, 1991: ANTIC TO BE CARCIN. OTHER PROT EQUIP:
SHOWER AND HYGIENIC FACILITIES FOR WASHING.

================== Physical/Chemical Properties ==================

HCC:N1
Melt/Freeze Pt:M.P/F.P Text:150F,66C
Spec Gravity:9.7G/CM3
Solubility in Water:INSOLUBLE
Appearance and Odor:SILVER COLOR CRYSTALS
Percent Volatiles by Volume:SUPDAT

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
ACIDS, OXIDIZERS, NH*4NO*3, C1F*3, BRF*3, HALOGENS.
Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAMES.
Hazardous Decomposition Products:PB FUMES, SN FUMES, CD FUMES.

==================== Disposal Considerations ====================

Waste Disposal Methods:CONSULT STATE, LOCAL, AND FEDERAL REGULATIONS
FOR PROPER DISPOSAL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.




http://hazard.com/msds/f2/bsc/bsckg.html Page 3 of 3

ALL Chemical Analysis PAGES IN THIS GROUP
NAMECAS
etiusa_com_FRAGOIL_1.asp N/A
etiusa_com_LIQSOAP_1.asp N/A
euclidchemical_com_027_55_C.asp N/A
euclidchemical_com_133_99_C.asp N/A
7440-02-0.asp 7440-02-0 7440-47-3 7439-89-6 1309-37-1
1344-28-1.asp 1344-28-1
7647-14-5.asp 7647-14-5 7558-79-4 7778-77-0 7447-40-7
7440-69-9.asp 7440-69-9 7439-92-1 7440-31-5 7440-43-9
evic_com_au_M750.asp N/A
7732-18-5.asp 7732-18-5
8052-41-3.asp 8052-41-3 64742-82-1 64742-48-9 103-65-1 25551-13-7 95-63-6
101-68-8.asp 101-68-8 9016-87-9 26447-40-5 103-71-9
115-10-6.asp 115-10-6 64-17-5
64742-47-8.asp 64742-47-8
farmoz_com_au_Aphidex_WG_msds.asp N/A
fc_bryanisd_org_MSDS.ws.asp N/A
56-81-5.asp 56-81-5 7732-18-5 9048-46-8
67-68-5.asp 67-68-5 64-17-5 7240-90-6
64-17-5.asp 64-17-5 75-28-5 74-98-6 90-43-7
ffgeneralsupply_com_9010.asp N/A
8008-20-6.asp 8008-20-6 64742-48-9 1344-28-1
fiberlock_com_3001_MSDS.asp N/A
111-76-2.asp 111-76-2 34590-94-8
111-76-2.asp 111-76-2 67-63-0
9011-14-7.asp 9011-14-7
111-76-2.asp 111-76-2
fiberlock_com_3007_MSDS.asp N/A
111-76-2.asp 111-76-2
5989-27-5.asp 5989-27-5
5989-27-5.asp 5989-27-5 1569-01-3
7732-18-5.asp 7732-18-5 34590-94-8 111-76-2 9016-45-9 6834-92-0 1310-58-3
112-34-5.asp 112-34-5
64-17-5.asp 64-17-5
13463-67-7.asp 13463-67-7
13463-67-7.asp 13463-67-7
13463-67-7.asp 13463-67-7
13463-67-7.asp 13463-67-7 1897-45-6
13463-67-7.asp 13463-67-7
13463-67-7.asp 13463-67-7 107-21-1
13463-67-7.asp 13463-67-7
fiberlock_com_fibertack_msds.asp N/A
37244-96-5.asp 37244-96-5 7732-18-5 1332-58-7 1313-13-9 1317-61-9 1310-58-3 7631-86-9
7732-18-5.asp 7732-18-5 14808-60-7 1317-65-3 25036-16-2 12001-26-2 111-77-3 85-68-7 13463-67-7 13983-17-0 8031-18-3
7722-84-1.asp 7722-84-1
fiberlock_com_iaq_2000_msds.asp N/A
fiberlock_com_iaq_2500_msds.asp N/A
13463-67-7.asp 13463-67-7 107-21-1
13463-67-7.asp 13463-67-7 1314-13-2
13463-67-7.asp 13463-67-7 1314-13-2
13463-67-7.asp 13463-67-7


HBCChem,Inc

Chemical Information Net chemcas.orgCopyright Reserved

Trading Lead

Leputech HPLC Laboratory