MATERIAL SAFETY DATA SHEET
Product Name: Bondline 7080
Chemical Name: Epoxy
Preparation Date: 11/8/1999
Revision Date: 2/9/2004
Revision: C
Section 1: Identification
Bondline Electronic Adhesives
756 N. Pastoria Avenue
Sunnyvale, CA 94085
Telephone: 408-830-9200 Fax: 408-830-9266
Web: www.bondline.net
Section 2: Hazardous Ingredients & Section 313 Supplier Notification
TLV per ACGIH1,3 Exposure Limit PEL 2,3
Hazardous Material Cas Number % Codes
2ppm N/A
Epich. Dimer Fatty Acid Based Resin 68475-94-5 <17 H
N/A N/A
Bisphenol A Epoxy resin 25068-38-6 Trade secret H
Hazard Codes
C = Carcinogen ( OSHA,NTP,IARC) 1= TLV means threshold limit values.
H= Hazardous ( OSHA ) 2= PEL means Permitted exposure limit set fourth by OSHA.
P= California Prop 65 ( Carcinogen ) 3= All exposure limits in mg/m3 values for airborne dust.
A= Superfund Amendments Reauthorization Act(SARA) a= mmpcf million particles per cubic foot of air.
b= respirable.
ACGIH= The American Conference of Governmental Industrial Hygienists
TWA= TWA means 8 hour time weighted average.
Section 3: Physical Data
Boiling point N/A
Vapor pressure @ 25癈 <1mm
Vapor density ( Air = 1 ) >1
Solubility in H2O Slight
Appearance Blue paste
Specific gravity 2.1
% Volatile by weight 0.07%
Evaporation rate N/A
Odor Slight
Section 4: Fire and Explosion Hazard Data
Flash point
Flammable Limits in Air Not Tested
Extinguishing media Carbon dioxide, dry chem, foam, water fog
Unusual fire & Explosion Hazd. Toxic fumes may be evolved upon exposure to heat or open flame. Exothermic reaction can
occur in large masses.
Special fire fighting procedure Self contained breathing apparatus and protective clothing should be worn.
Page 1
MATERIAL SAFETY DATA SHEET
Bondline 7080
Section 5: Health and Hazard Information
Effects of overexposure
Inhalation May be harmful if inhaled. Can cause irritation to the nose, throat and respiratory tract, and nausea.
Eye contact Can cause severe irritation to the eyes.
Irritation upon direct contact. Prolonged exposure may result in skin sensitization. Wash skin thoroughly
Skin Contact
with soap and water.
First aid & Emergency procedure
Eye contact Flush with water for at least 15 minutes, can cause severe irritation to the eyes. Seek medical attention.
Skin contact Wash immediately with soap and water
Inhaled Remove to fresh air immediately.
Ingestion Seek medical attention immediately and show MSDS.
Suspected cancer agent Product is not considered to be carcinogenic.
Section 6: Reactivity Data
Stability Stable when stored at -40癈 or colder. Will harden at room temperature.
Incompatibility ( materials to avoid ) Strong oxidizing agents
Conditions to avoid Excessive heat or flames
Haz. decomposition products Carbon monoxide, acids, aldehydes
Hazardous polymerization Will not occur
Section 7: Spill, leak and disposal procedures
Spill or leak Use paper towels to wipe up epoxy. Epoxy will harden at room temperature.
Waste disposal method Cure epoxy ( see data sheet ) Can be disposed in land fill.
Section 8: Special protection information
Ventilation Local exhaust is preferred. Use material in a well ventilated work area.
Eye protection Safety goggles.
Gloves Rubber gloves or finger cottles.
Respiratory protection Use NIOSH approved dust mask, or NIOSH approved organic respirator if needed.
Curing ovens vent to outdoors
Section 9: Special precautions
Storage and handling Refrigerated storage at -40癈 or colder is required.
Shelf life 6 months when stored at -40癈 or colder.
Section 10: Regulatory Information
SARA/TITLE III-Toxic Chemicals List: This product contains chemicals subject to the reporting requirements of section 313
of Title III of the Superfund Amendments and Reauthorization Act of 1986 part 372.
Cas Number %
Epichlorohydrin
106-89-8 <1ppm
107-13-1 <5ppm Acrylonitrile
TSCA Inventory Status: Chemical components listed on TSCA Inventory
California Prop. 65: This product does contain toxic chemicals currently on the California
list of known carcinogens and reproductive toxins.
<0.5 ppm
Disclaimer: All statements, technical information and recommendations contained herein are based on tests we believe to be accurate, but the accuracy or
completeness thereof is not guaranteed, and the following is made in lieu of warranty express or implied. Seller and manufacturer's only obligation shall be to
replace such quantity of the product proved to be defective. Neither seller nor manufacturer shall be liable for any injury, loss or damage, direct or
consequential, arising from use or inability to use the project. Before using, user shall determine the suitability of the product for his/her intended use, and user
assumes all risk and liability whatsoever in connection therewith. No statement or recommendation not contained herein shall have any force or effect unless in
an agreement signed by officers of seller and manufacturer.