http://siri.org/msds/f2/cgn/cgnck.html
TREIBACHER SCHLEIFMITTEL CORP. -- LIONITE, ALUMINUM OXIDE -- 5350-00-174-6460
===================== Product Identification =====================
Product ID:LIONITE, ALUMINUM OXIDE
MSDS Date:11/01/1994
FSC:5350
NIIN:00-174-6460
MSDS Number: CGNCK
=== Responsible Party ===
Company Name:TREIBACHER SCHLEIFMITTEL CORP.
Address:2000 COLLEGE AVE.
Box:1438
City:NIAGARA FALLS
State:NY
ZIP:14302
Country:US
Info Phone Num:716-286-1250
Emergency Phone Num:716-286-1234
CAGE:KO436
=== Contractor Identification ===
Company Name:TREIBACHER SCHLEIFMITTEL CORP.
Address:2000 COLLEGE AVE.
Box:1438
City:NIAGARA FALLS
State:NY
ZIP:14302
Country:US
Phone:716-286-1250
CAGE:KO436
============= Composition/Information on Ingredients =============
Ingred Name:ALUMINUM OXIDE (AL202)
CAS:1344-28-1
RTECS #:BD1200000
Fraction by Wt: 99.4%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:10 MG/M3
ACGIH TLV:10 MG/M3
Ingred Name:SODIUM OXIDE (NA20)
CAS:12401-86-4
RTECS #:WC4800000
Fraction by Wt: 0.3%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:2 MG/M3
ACGIH TLV:2 MG/M3
Ingred Name:SILICON DIOXIDE (SIO2)
CAS:112945-52-5
RTECS #:VV7310000
Fraction by Wt: 0.2%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:10 MG/M3
ACGIH TLV:10 MG/M3
Ingred Name:IRON OXIDE (FE203)
CAS:1309-37-1
RTECS #:NO7400000
Fraction by Wt: 0.1%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:10 MG/M3
ACGIH TLV:5 MG/M3
Ingred Name:MAGNESIUM OXIDE (MGO)
CAS:1309-48-4
RTECS #:OM3850000
Fraction by Wt: 0.1%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:15 MG/M3
ACGIH TLV:10 MG/M3
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: IRRITATION. SKIN: IRRITATION.
INHAL: RESPIRATORY DISORDERS, MUCOUS MEMBRANE IRRIT. SYMPTOMS OF
EXCESS EXPOSURE MIGHT INCLUDE DEPOSITS OF MATERIALS IN EYES, EARS,
NASAL PASSAGES.
Medical Cond Aggravated by Exposure:INDIVIDUALS W/IMPAIRED PULMONARY
FUNCTION SHOULD NOT BE SUBJECT TO EXCESS AIRBORNE CONCENTRATIONS.
======================= First Aid Measures =======================
First Aid:EYE: FLUSH W/WATER. SKIN: FLUSH W/WATER. INHAL: REMOVE TO
FRESH AIR. IN ALL CASES, GET MED AID.
===================== Fire Fighting Measures =====================
Flash Point:NON-FLAMMABLE
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:NA
Fire Fighting Procedures:NA
Unusual Fire/Explosion Hazard:NA
================== Accidental Release Measures ==================
of 2 10/17/2007 4:22 AM
http://siri.org/msds/f2/cgn/cgnck.html
Spill Release Procedures:NORMAL PRECAUTION FOR INERT OR NUISANCE DUST
OR PARTICLES.
====================== Handling and Storage ======================
Handling and Storage Precautions:USE HANDLING PROCEDURES WHICH WILL
LIMIT EXPOSURE TO EXCESSIVE AIRBORNE DUST.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE NIOSH APPROVED RESPIRATOR DEVICES FOR
NUISANCE DUST.
Ventilation:USE LOCAL EXHAUST TO KEEP AIRBORNE CONCENTRATIONS BELOW
TLV.
Protective Gloves:REQUIRED
Eye Protection:REQUIRED
Other Protective Equipment:ARM SLEEVES OR BARRIER CREAMS MAY BE USEFUL
TO PREVENT SKIN CONTACT.
Work Hygienic Practices:MAINTAIN NORMAL HOUSEKEEPING PROCEDURES FOR
NUISANCE DUST.
Supplemental Safety and Health
NK
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:NA
Melt/Freeze Pt:M.P/F.P Text:3722F,2050C
Vapor Pres:0
Vapor Density:NA
Spec Gravity:3.95 H2O =1
Evaporation Rate & Reference:NA
Solubility in Water:INSOLUBLE
Appearance and Odor:LIGHT TO DARK BROWN, NO ODOR.
Percent Volatiles by Volume:NA
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
INCOMPATIBLE W/HOT CHLORINATED RUBBER.
Stability Condition to Avoid:NA
Hazardous Decomposition Products:NA
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/FEDERAL, STATE AND
LOAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
of 2 10/17/2007 4:22 AM
|