ACL Incorporated ACL 10R Floor Sealer
MSDS Information
Section 1. CHEMICAL PRODUCT SECTION
STATICIDE庐 ACL 10R Floor Sealer
Product Name:
Product Number: # ACL 10R-1, ACL 10R-5, ACL 10R-2
Manufacturer: ACL Incorporated For Chemical Emergency,
1960 E. Devon Avenue Spill, Leak, Fire Exposure,
Elk Grove Village, IL 60007 Or Accident Call INFOTRAC
PH: (01) 847.981.9212 [U.S.A.] DAY OR NIGHT (01) 800.535.5053
FAX: (01) 847.981.9278 [U.S.A.]
Section 2. INFORMATION ON HAZARDOUS INGREDIENTS
CHEMICAL C.A.S. Number Weight %
Ektasolve 2807-30-9 6鈥?8
Butyl Carbitol 112-34-5 1鈥?3
EB Glycol 111-76-2 <1
M-Pyrol 872-50-4 <1
Propylene Glycol 57-55-6 <1
Alkylamines 121-44-8 <2
OSHA HAZARDOUS COMPONENTS (29 CFR 1910.1200):
Exposure Limits 8 Hours TWA (PPM)
OSHA PEL ACGIH TLV Supplier
M-Pyrol 100 NE NE
Section 3. HAZARD IDENTIFICATION
Potential Health Effects:
Inhalation: No specific information available. Contains materials that could cause
headaches, nauseous, dizziness and respiratory irritations if inhaled.
Eyes: No specific information available. Contains material that may cause eye
injury which may persist for several days.
Skin: No specific information available. Contains materials that may be moderately
toxic.
Ingestion: No specific information available. Contains materials that my be slightly
toxic.
Chronic Effect Of Overexposure: No specific information available. Contains
solvents that are reported to be associated with central nervous system damage after
repeated and prolonged use. Contains solvents that may cause injury to liver,
kidneys, bone marrows and blood cells after repeated over exposure.
Page 1 of 6
ACL Incorporated ACL 10R Floor Sealer
Section 4. FIRST AID MEASURES
Inhalation: In case of exposure to a high concentration of vapor or ist, remove
person to fresh air. If breathing has stopped, administer CPR and seek medical
attention immediately.
Eye Contact: Flush with water for at least 15 minutes, contact a physician if
necessary.
Skin Contact: Remove contaminated clothing and wash contact area with soap and
water for 15 minutes.
Ingestion: If appreciable quantities are swallowed, seek medical attention.
Section 5. FIRE FIGHTING MEASURES
Flash Point & Method: NA
Flammable Limits: LEL: NA UEL: NA
Autoignition Temperature: NA
General Hazard: Remove all ignition sources.
Fire Fighting Instructions: Fire fighters should wear self contained breathing apparatus
and complete personal protective equipment when entering confined where potential for
exposure to vapors or products of combustion exists.
Extinguishing Media: Use carbon dioxide or dry chemical for small fires, aqueous foam
or water for large fires.
Unusual Fire & Explosion Hazards: Closed containers may rupture (due to buildup of
pressure) when exposed to extreme heat.
Section 6. ACCIDENTAL RELEASE MEASURES
Land spill: Dike spill. Absorb with inert material and collect for disposal. Flush area
with water. Prevent washing from entering water ways.
Water spill: NA
Section 7. HANDLING AND STORAGE
Handling: Wash thoroughly after handling.
Storage Temperatures: Ambient (40掳 - 90掳 F)
Storage Pressure: Atmospheric
General: Do not Freeze. Keep away from heat. Fumes produced when heated. Ground
containers when transferring from one to another. Do not apply to hot surfaces or use in
areas where exposed to electric sparks
Page 2 of 6
ACL Incorporated ACL 10R Floor Sealer
Section 8. EXPOSURE CONTROL / PERSONAL PROTECTION
Engineering Controls:
(X) Local Exhaust ventilation acceptable
() Mechanical ventilation recommended
() Use explosion 鈥? proof ventilation equipment.
() Do not use in confined space without mechanical ventilation
equipment.
See section 2 for component exposure guidelines.
Personal Protection:
Respirator:
Wear a properly fitted NIOSH/MSHA approved resprirator
whenever exposure to vapor/mist is likely unless levels are below
applicable limits.
Hand Protection:
( X) Gloves Recommended.
( ) Solvex ( X) Neoprene
( )Butyl ( ) Buna
( ) Natural Latex ( ) Cotton/Jersey
Eye Protection:
( ) Safety Glasses with sideshields ( X) Chemical Goggles
Other Recommendations:
For operations where contact can occur, a safety shower and eye wash
station should be available.
Section 9. PHYSICAL AND CHEMICAL PROPERTIES
Boiling Point鈥︹?︹??.. 鈥?212-301掳 F % Volatile鈥︹?︹?︹?︹?︹?︹?︹??10
Solubility in Water鈥?..鈥iscible Appearance:鈥︹?︹?︹?︹??.Clear
Vapor Density (Air=1)鈥eavier than air Evaporation Rate鈥lower than Butyl
Physical State鈥︹?︹?︹?︹?︹??.liquid Odor鈥︹?︹?︹?︹?︹?︹?︹?? Mild
Section 10. STABILITY AND REACTIVITY
General: This product is stable under normal storage conditions.
Hazardous Polymerization: Will not occur
Incompatible Materials and Conditions to Avoid:
Avoid excessive heat. Fumes produced when heated.
Contamination with strong acids, bases, amines, or mercaptans can cause
polymerization.
Hazardous Decomposition: Fumes produced when heated decomposition may include:
Carbon monoxide, carbon dioxide.
Page 3 of 6
ACL Incorporated ACL 10R Floor Sealer
Section 11. TOXICOLOGY INFORMATION
Results of Component Toxicity Test Performed:
No information.
Human Experience:
No information.
Section 12. ECOLOGICAL INFORMATION
No information
Section 13. DISPOSAL CONSIDERATIONS
RCRA 40 CFR 261 Classifications:
As packaged, if this product becomes a waste, it does not meet the criteria of a hazardous
waste as defied under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261,
since it has neither the characteristics of Subpart C nor is listed in Subpart D.
Federal, State, and Local laws governing disposal of material can differ.
Ensure proper disposal compliance with proper authorities before disposal.
Section 14. TRANSPORTATION INFORMATION
U.S. DOT Information
Basic Description: NON HAZARDOUS MATERIAL
Proper Shipping Name: NA
Hazard Class: NA
Packaging Group: NA
UN Number: NA
Limitations: NA
IATA
Proper Shipping Name: NON HAZARDOUS MATERIAL
Hazard Class: NA
Packing Group: NA
UN Number: NA
Limitations: NA
Page 4 of 6
ACL Incorporated ACL 10R Floor Sealer
Section 15. REGULATORY INFORMATION
United States Federal Regulations:
MSDS complies with the OSHA Hazard Communication Rule, 29 CFR 1910.1200.
CERCLA/Superfund, 40 CFR 117. 302:
---None of the chemicals have a reportable quantity--
SARA Superfund and Reauthorization Act of 1986 Title III sections 302, 311,312 and 313:
Section 302 鈥? Extremely hazardous substances (40 CFR 355):
---None of the chemicals are Section 302 hazards ---
Section 311/312 鈥? Material Safety Data Sheet Requirements (40 CFR 370):
(X ) By our hazard evaluation, this product is non-hazardous.
() By our hazard evaluation, this product is hazardous. It should be reported
under the following EPA hazard.
() Immediate (acute) health hazard
() Delayed (chronic) health hazard
() Sudden release of pressure hazard
() Reactive hazard
Section 313 鈥? List of Toxic Chemicals (40CFC 372):
This product contains the following chemicals ( at level of 1% or greater)
which are found on the 313 list of Toxic Chemicals.
Chemical C.A.S. NUMBER WEIGHT %
Alkylamines 121-44-8 <2
Toxic Substance Control Act (TSCA): All substances are TSCA listed.
Resource Conservation and Recovery Act (RCRA 40 CFR 261) Subpart C & D:
Refer to Section 13 for RCRA classification.
Federal Water Pollution Control Act, Clean Water Act, 40 CFR 401.15 (formerly section 307) 40 CFR 116
(formerly section 311)
This product contains no chemicals which are listed
Clean Air Act: No information
STATE REGULATIONS:
For details on your regulatory requirements you should contact the appropriate agency in your state
STATE CHEMICAL C.A.S. NUMBER WEIGHT %
----no information----
California Proposition 65: --- None of the chemicals are on the Proposition 65 list---
INTERNATIONAL REGULATIONS:
Canada WHMIS: This product has been classified in accordance with the hazard criteria of the CPR and the
MSDS contains all the information required by the CPR.
Europe EINECS Numbers: Ektasolve #220-548-6
Butyl Carbitol #203-961-6
EB Glycol (313) #203-905-0
M-Pyrol # 212-828-1
Propylene Glycol #57-55-6
Alkylamines # 204-469-4
Page 5 of 6
ACL Incorporated ACL 10R Floor Sealer
Sections 16. OTHER INFORMATION
LABEL INFORMATION:
For Shipping Label information refer to section 14
NFPA HAZARD RATING:
(0) Fire (1 ) Health (0) Reactivity
REVISION DATES, SECTIONS, REVISED BY:
15-FEB-92 Original release date
02-APR-01, Reviewed
22-APR-05 Revised all Sections, mkb
ABBREVIATIONS USED IN THIS DOCUMENT:
NE 鈥? Not Established, NA 鈥? Not Applicable, NIF 鈥? No Information Found
ABRIDGED LIST OF REFERENCES:
Code of Federal Regulations (CFR)
The Sigma-Aldrich Library of Regulatory and Safety Data
Chemical Guide and OSHA Hazardous Communication Standard
The Environmental Protection Agency (www.epa.gov)
American National Standards Institute
To the best of our knowledge, the information contained herein is accurate.
However, neither ACL STATICIDE nor any of its subsidiaries assumes any liability
whatsoever for the accuracy or completeness of the information contained herein.
Final determination of suitability of any material is the sole responsibility of the user. All
materials may present unknown hazards and should be used with caution. Although certain
hazards are described herein, we cannot guarantee that these are the only hazards which
exist.
Page 6 of 6
|