MSDS No.
L8
Date Issued
MATERIAL SAFETY DATA SHEET
Nov. 15, 1985
Date Revised
April 4, 2008
Chemical/Trade Name (identity used on label) Chemical Family/Classification HMIS Rating for Sulfuric Acid
Lead Acid Battery Electric Storage Battery 3 0 2 X X= Acid
Synonyms/Common Name DOT, IATA and IMO Description
SLI Battery Battery, Wet, Filled with Acid, UN 2794, Class 8
Company Name Address
Johnson Controls Battery Group Inc. P.O. Box 591
Division or Department Milwaukee, WI 53201
Power Solutions
CONTACT TELEPHONE NUMBER
Questions Concerning MSDS Day:
Industrial Hygiene, Safety & Security - SLI: (800) 333-2222 ext. 3138
Automotive Systems, Battery
Transportation Emergencies
CHEMTREC 24 Hours: (800) 424-9300
II. Hazardous Ingredients
Material % by Wt. CAS Number Eight Hour Exposure Limits
OSHA ACGIH Other
PEL TLV
Specific Chemical Identity NIOSH
REL
Lead
50 g/m 150 g/m 100 g/m
3 3 3
Common Name 34 7439-92-1
Grid
Specific Chemical Identity NIOSH
REL
Lead Dioxide
50 g/m 150 g/m 100 g/m
3 3 3
Common Name 31 1309-60-0
Lead Oxide
Specific Chemical Identity NIOSH
REL
Lead Sulfate
<1 50 g/m 150 g/m 100 g/m
3 3 3
Common Name 7446-14-2
Anglesite
3
Specific Chemical Identity 1 mg/m NIOSH
STEL REL
Sulfuric Acid (35%)
3 3
1 mg/m3
34 7664-93-9 1mg/m 0.2 mg/m
Common Name
(respirable
Battery Electrolyte (Acid)
thoracic fraction)
NOTE: The contents of this product are toxic chemicals that are subject to the reporting requirements of
section 302 and 313 of the Emergency Planning and Community Right-To-Know Act of 1986
(40CFR 355 and 372).
III. Physical Data
Material is (at normal temperatures) Appearance and Odor
Solid Liquid Battery Electrolyte (acid) is a clear to cloudy liquid
with slight acidic odor. Acid saturated lead oxide
Boiling Point (at 760 mm Hg) Melting Point is a dark reddish-brown to gray solid with slight
Lead 1755oC Batt. Electrolyte Lead 327.4oC acidic odor.
o
(Acid) 110-112 C
o
Specific Gravity (H2O =1) (mm Hg at 20 C) Z(PSIG)
Vapor Pressure
Battery Electrolyte (Acid) 1.210 - 1.300 Battery Electrolyte (Acid) 11.7
Vapor Density (Air =1) Solubility is H2O
Battery Electrolyte (Acid) 3.4 Lead and Lead Dioxide are not soluble.
Battery Electrolyte (acid) is 100% soluble in water.
% Volatile By Weight Evaporation rate (Butyl Acetate = 1)
Not Determined Not Determined
Form 8573 (Rev. 06/02)
IV. Health Hazard Information
NOTE: Under normal conditions of battery use, internal components will not present a health hazard. The following
information is provided for battery electrolyte (acid) and lead for exposure that may occur during battery production or
container breakage or under extreme heat conditions such as fire
ROUTES AND METHODS OF ENTRY
Inhalation
Acid mist generated during battery formation may cause respiratory irritation. Spillage of acid from batteries in
confined areas may also lead to exposure to sulfuric acid mist.
Skin Contact
Battery electrolyte (acid) can cause severe irritation, burns and ulceration.
Skin Absorption
Skin absorption is not a significant route of entry.
Eye Contact
Battery electrolyte (acid) can cause severe irritation, burns, and cornea damage upon contact.
Ingestion
Hands contaminated by contact with internal components of a battery can cause ingestion of lead/lead compounds.
Hands should be washed prior to eating, drinking, or smoking.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
Acute Effects
Acute effects of overexposure to lead compounds are GI (gastrointestinal) upset, loss of appetite, diarrhea, constipation
with cramping, difficulty in sleeping, and fatigue. Exposure and/or contact with battery electrolyte (acid) may lead to
acute irritation of the skin, corneal damage of the eyes, and irritation of the mucous membranes of the eyes and upper
respiratory system, including lungs.
Chronic Effects
Lead and its compounds may cause chronic anemia, damage to the kidneys and nervous system. Lead may also cause
reproductive system damage and can affect developing fetuses in pregnant women. Battery electrolyte (acid) may lead
to scarring of the cornea, chronic bronchitis, as well as erosion of tooth enamel in mouth breathers in repeated
exposures.
POTENTIAL TO CAUSE CANCER
The National Toxicological Program (NTP) and The International Agency for Research on Cancer (IARC) have classified
"strong inorganic acid mist containing sulfuric acid" as a Category 1 carcinogen, a substance that is carcinogenic to
humans. The ACGIH has classified "strong inorganic acid mist containing sulfuric acid" as an A2 carcinogen
(suspected human carcinogen). These classifications do not apply to liquid forms of sulfuric acid or sulfuric acid
solutions contained within a battery. Inorganic acid mist (sulfuric acid mist) is not generated under normal use of this
product. Misuse of the product, such as overcharging, may result in the generation of sulfuric acid mist.
The NTP and the IARC have classified lead as an A3 carcinogen (animal carcinogen). While the agent is carcinogenic in
experimental animals at relatively high doses, the agent is unlikely to cause cancer in humans except under
uncommonly high levels of exposure. For further information, see the ACGIH's pamphlet, 1996 Threshold Limit Values
and Biological Exposure Indices.
EMERGENCY AND FIRST AID PROCEDURES
Inhalation
Remove from exposure and consult a physician if any of the acute effects listed above develop.
Skin
Wash thoroughly with soap and water. If acid is splashed on clothing, remove and discard. If acid is splashed in
shoes, remove them immediately and discard. Acid cannot be removed from leather.
Eyes
Immediately rinse with cool running water for at least 15 minutes. Seek medical attention immediately after rinsing.
Ingestion
Lead/Lead compounds: Consult a physician.
Battery Electrolyte (Acid): Do not induce vomiting. Refer to a physician immediately.
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE
Inorganic lead and its compounds can aggravate chronic forms of kidney, liver, and neurological diseases. Contact of
battery electrolyte (acid) with the skin may aggravate skin diseases such as eczema and contact dermatitis.
V. Fire and Explosion Data
Flash Point (test method) Autoignition Temperature Flammable Limits in Air, % by Vol.
Hydrogen - 259oC Hydrogen 580篊 Hydrogen LEL - 4.1 UEL - 74.2
Extinguishing Media
Dry chemical, foam, or CO2
Special Fire Fighting Procedures
Use positive pressure, self-contained breathing apparatus.
Unusual Fire and Explosion Hazard
Hydrogen and oxygen gases are produced in the cells during normal battery operations, hydrogen is
flammable and oxygen supports combustion. These gases enter the air through the vent caps. To avoid
the chance of a fire or explosion, keep sparks and other sources of ignition away from the battery.
VI. Reactivity Data
Stability Conditions to Avoid
Unstable Stable Sparks and other sources of ignition may ignite hydrogen gas.
Incompatibility (materials to avoid)
Lead/lead compounds: Potassium, carbides, sulfides, peroxides, phosphorus, sulfur.
Battery electrolyte (acid): Combustible materials, strong reducing agents, most metals, carbides, organic
materials, chlorates, nitrates, picrates, and fulminates.
Hazardous Decomposition Products
Lead/Lead compounds: Oxides of lead and sulfur
Battery electrolyte (acid): Hydrogen, sulfur dioxide, sulfur trioxide
Hazardous Polymerization Conditions to Avoid
High temperature. Battery electrolyte (acid) will react with water to
May Occur Will Not Occur produce heat. Can react with oxidizing or reducing agents.
VII. Control Measures
Engineering Controls
Store lead acid batteries with adequate ventilation. Room ventilation is required for batteries utilized for
standby power generation. Never recharge batteries in an unventilated, enclosed space.
Work Practices
Make certain vent caps are on tightly. Place a minimum of two layers of corrugated cardboard between
layers of batteries. When stacking in trailer, stack no more than three layers high. Use a battery carrier
to lift a battery or place hands at opposite corners to avoid spilling acid through the vents. Avoid contact
with internal components of the batteries.
PERSONAL PROTECTIVE EQUIPMENT
Respiratory Protection
None required under normal handling conditions. During battery formation (high-rate charge condition),
acid mist can be generated, which may cause respiratory irritation. If irritation occurs, wear a respirator
suitable for protection against acid mist.
Eyes and Face
Chemical splash goggles are preferred. Also acceptable are "Visor-Gogs" or a chemical face shield
worn over safety glasses with solid side shields.
Hands, Arms, and Body
Vinyl-coated, PVC, gauntlet-type gloves with rough finish.
Other Special Clothing and Equipment
Safety shoes worn with rubber or neoprene boots or steel-toed rubber or neoprene boots worn over
socks. Place pants legs over boots to keep acid out of boots. All footwear must meet requirements of
ANSI Z41.1-1991.
VIII. Safe Handling Precautions
Hygiene Practices
Wash hands thoroughly before eating, drinking, or smoking after handling batteries.
Protective Measures to be Taken During Non-Routine Tasks, Including Equipment Maintenance
Wear recommended eye protection. If clothing becomes saturated with acid, remove and wash affected
area with water for 15 minutes. Discard saturated clothing.
SPILL OR LEAK PROCEDURES
Protective Measures to be Taken if Material is Released or Spilled
Remove combustible materials and all sources of ignition. Contain spill by diking with soda ash (sodium
carbonate) or quicklime (calcium oxide). Cover spill with either chemical. Mix well. Make certain the
mixture is neutral, then collect residue and place in a drum or other suitable container. Dispose of as a
hazardous waste.
Wear acid-resistant boots, chemical face shield, chemical splash goggles, and acid-resistant gloves.
DO NOT RELEASE UNNEUTRALIZED ACID!
Waste Disposal Method
Battery Electrolyte (Acid): Neutralize as above for a spill, collect residue, and place in a drum or suitable
container. Dispose of as a hazardous waste.
DO NOT FLUSH LEAD-CONTAMINATED ACID INTO SEWER.
Batteries: Send to lead smelter for reclamation following applicable Federal, state, and local regulations.
OTHER HANDLING AND STORAGE PRECAUTIONS
An eyewash fountain and safety shower should be located in or near the production or storage area(s) for
lead/lead acid batteries. Such storage areas should be equipped with a containment facility which
captures acid spills so that they may be neutralized, collected, and disposed of properly.
IX. Other Regulatory Information
TSCA Registry: Ingredients listed in the TSCA Registry are lead, lead oxide, lead sulfate and sulfuric acid.
Proposition 65 Warning: Battery posts, terminals and related accessories contain lead and lead compounds, chemicals known
to the State of California to cause cancer and reproductive harm. Batteries also contain other chemicals known to the State of
California to cause cancer. Wash hands after handling.
Disclaimer: This information has been compiled from sources considered to be dependable and is, to the best of our
knowledge and belief, accurate and reliable as of the date compiled. However, no representation, warranty (either
express or implied) or guarantee is made to the accuracy, reliability or completeness of the information contained
herein. This information relates to the specific material designated and may not be valid for such material used in
combination with any other materials or in any process. It is the user's responsibility to satisfy himself as to the
suitability and completeness of this information for his own particular use. We do not accept liability for any loss or
damage that may occur, whether direct, indirect, incidental or consequential, from use of this information.
|