MATERIAL SAFETY DATA SHEET Page 1 or 4
PRODUCT NAME: PVC COMPOSITE MATERIAL
Rendered by Manufacturer and Released to: PHONE NUMBER
123 Columbia Court North, Suite 201, Chaska MN 55318 1-800-448-3134
CHEMICAL NAME AND SYNONYMS:
FUSED PVC VINYLPlastisol COMPOSITE
TRADE NAME AND SYNONYMS:
1.0 LB> / 1.5 LB./ft2 ?Loaded Solid Barrier, Solid Sound Barrier WITH VINYL FOAM COMPOSITE
CHEMICAL FAMILY: FORMULA:
Plasticized Polyvinylchloride Dispersion (C2H3CI) x Mixture
C.A.S. REGISTRY NUMBER: ISSUE DATE: REVISION DATE:
See Next Section 06/10/2005 10/9/99
II. HAZARDOUS INGREDIENTS / COMPOSITION INFORMATION
ITEM CAS Number % TLV Hazard
This product contains no known hazardous ingredients as defined under the Hazardous
Communication Program Standard, Section 1910.1200
SARA Title III Information ?See `Regulatory Information' Section, Page 4
*See `Additional Comments' Section, Page 4
III. HEALTH HAZARD SUMMARY
SIGNS AND SYMPTOMS OF EXPOSURE:
This product contains 15-16% mixed phthalate esters. They have low toxicity. AOGIH and OSHA
have not established specific exposure limits for these plasticizers, but chemically-similar plasticizers
have OSHA/AOGIH exposure limits of 5 mg/m3, 8 hour time weighted average.
Subjecting the material to temperature above 250癋 may liberate modest quantities of plasticizer
( ~ 2%). At temperatures above 400癋, the product may decompose to HCI, CO2, and other gases.
PRIMARY ROUTES OF EXPOSURE: EXPOSURE LIMITS: TLV
Inhalation of Processing Vapors
TOXICOLOGICAL PROPERTIES:
?PLASTICIZER PORTION ONLY ?br>
Upon exposure, these plasticizers represent a low hazard in the areas of inhalation, eyes, skin, and
ingestion, for the usual industrial or commercial handing by trained personnel.
?Soundproofing Products ?SonexTM Ceiling & Wall Panels ?Sound Control Curtains ?Equipment Enclosures ?Acoustical Baffles & Banners ?Solid Wood & Veneer Acoustical Ceiling & Wall Systems
?Professional Audio Acoustics ?Vibration & Damping Control ?Fire Retardant Acoustics ?Hearing Protection ?Moisture & Impact Resistant Products ?Floor Impact Noise Reduction
?Sound Absorbers ?Noise Barriers ?Fabric Wrapped Wall Panels ?Acoustical Foam (Egg Crate) ?Acoustical Sealants & Adhesives ?Outdoor Noise Control ?Assistive Listening Devices
?OSHA, FDA, ADA Compliance ?On-Site Acoustical Analysis ?Acoustical Design & Consulting ?Large Inventory ?Fast Shipment ?No Project too Large or Small ?Major Credit Cards Accepted
Acoustical Surfaces, Inc.
Acoustical
Surfaces, Inc.
SOUNDPROOFING, ACOUSTICS, NOISE & VIBRATION CONTROL SPECIALISTS
We identify and
123 Columbia Court North = Suite 201 = Chaska, MN 55318
(952) 448-5300 = Fax (952) 448-2613 = (800) 448-0121
Email: sales@acousticalsurfaces.com
Vi s i t o u r We b s i t e : w w w. a c o u s t i c a l s u r f a c e s . c o m
Your Noise Problems
Sound Transmission Obscuring Products
Soundproofing, Acoustics,
Noise & Vibration
Control Specialists
We Identify and S.T.O.P. Your Noise Problems
TM
IV. EMERGENCY AND FIRST AIR PROCEDURES
EYE CONTACT:
Flush eyes for 15 minutes with plenty of water, Call a physician if irritation persists.
SKIN CONTACT:
Wash with soap and water.
INHALATION:
When heated to decomposition, provide ventilation or use a NIOSH-approved respirator.
INGESTION:
N/A
V. PHYSICAL DATA
SPECIFIC GRAVITY (H2O = 1 g/cm3):
BOILING POINT:
2.14 g/cm3 (solid at 0.090 in)
VAPOR PRESSURE: VAPOR DENSITY (AIR = 1):
FREEZING POINT: MOLECULAR WT.:
VAPOR PRESSURE: VAPOR DENSITY (AIR = 1):
SOLUBILITY IN WATER: APPEARANCE AND ODOR:
Not soluble Solid; Mild characteristic odor
VI. FIRE AND EXPLOSION HAZARD DATA
FLASH POINT (METHOD USED): AUTO-IGNITION TEMPERATURE: FLAMMABLE LIMITS (% BY VOL):
>400 F. COC >600 F LEL N/A UEL
EXTINGUISHING MEDIA:
Fires involving this product can be extinguished by dry chemical, CO2, foam, or water. Use
NIOSH-approved pressure demand self-contained breathing apparatus, due to possible liberation
of HCI, CO, or other gasses.
UNUSUAL FIRE AND EXPLOSION HAZARDS:
None Known
VII. REACTIVITY DATA
STABILITY: CONDITIONS TO AVOID
Unstable None
x
Stable
INCOMPATIBILITY (Materials to Avoid):
Not Reactive
HAZARDOUS DECOMPOSITION PRODUCTS:
Thermal Oxides of Carbon (CO, CO2).
HAZARDOUS POLYMERIZATION: CONDITIONS TO AVOID
Unstable None
x
Stable
Acoustical Surfaces, Inc.
Acoustical
Surfaces, Inc.
SOUNDPROOFING, ACOUSTICS, NOISE & VIBRATION CONTROL SPECIALISTS
We identify and
123 Columbia Court North = Suite 201 = Chaska, MN 55318
(952) 448-5300 = Fax (952) 448-2613 = (800) 448-0121
Email: sales@acousticalsurfaces.com
Vi s i t o u r We b s i t e : w w w. a c o u s t i c a l s u r f a c e s . c o m
Your Noise Problems
Sound Transmission Obscuring Products
Soundproofing, Acoustics,
Noise & Vibration
Control Specialists
We Identify and S.T.O.P. Your Noise Problems
TM
VIII. OCCUPATIONAL CONTROL PROCEDURES
EYE PROTECTION:
N/A.
SKIN PROTECTION:
N/A.
RESPIRATORY PROTECTION:
When heated to decomposition, provide ventilation or NIOSH-approved chemical cartridge respirator.
OTHER PROTECTIVE EQUIPMENT:
VENTILATION:
IX. SPILL, LEAK OR DISPOSAL INFORMATION
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED:
Re-roll, pick-up, sweep, shovel, or vacuum
WASTE DISPOSAL METHOD:
Waste vinyl is not a hazardous material as defined by the Resource Conservation and Recovery Act. This
material is suitable for landfilling or component recovery. Vinyl material may be incinerated under conditions
which control associated chlorine formation.
X. SPECIAL STORAGE / HANDLING REQUIREMENTS
Store product below 120癋 to minimize the volatilization of the plasticizer components. Follow good
ergonomic principles when handling.
XI. LABEL REQUIREMENTS
N/A
Acoustical Surfaces, Inc.
Acoustical
Surfaces, Inc.
SOUNDPROOFING, ACOUSTICS, NOISE & VIBRATION CONTROL SPECIALISTS
We identify and
123 Columbia Court North = Suite 201 = Chaska, MN 55318
(952) 448-5300 = Fax (952) 448-2613 = (800) 448-0121
Email: sales@acousticalsurfaces.com
Vi s i t o u r We b s i t e : w w w. a c o u s t i c a l s u r f a c e s . c o m
Your Noise Problems
Sound Transmission Obscuring Products
Soundproofing, Acoustics,
Noise & Vibration
Control Specialists
We Identify and S.T.O.P. Your Noise Problems
TM
XII. REGULATORY INFORMATION
ITEM C.A.S. Number %
This product contains no known SARA Title III, 313 reportable chemicals at or above de minis amounts.
CMA TRANSPORTATION EMERGENCY ASSISTANCE CHEMTREC (800) 424-9300
ADDITIONAL COMMENTS
PREPARED BY: REVIEWED BY:
Ron L. King Ron L. King
Chemist/Safety Officer Chemist/Technical Director
"Information on this form is furnished solely or the purpose of compliance with the Occupational Safety and
Health Act of 1970 and applicable regulations, and should not be used for any other purpose. No warranty,
expressed or implied, of merchantability, fitness for purpose, or any other nature regarding this data or the
product is made herein."
?Soundproofing Products ?SonexTM Ceiling & Wall Panels ?Sound Control Curtains ?Equipment Enclosures ?Acoustical Baffles & Banners ?Solid Wood & Veneer Acoustical Ceiling & Wall Systems
?Professional Audio Acoustics ?Vibration & Damping Control ?Fire Retardant Acoustics ?Hearing Protection ?Moisture & Impact Resistant Products ?Floor Impact Noise Reduction
?Sound Absorbers ?Noise Barriers ?Fabric Wrapped Wall Panels ?Acoustical Foam (Egg Crate) ?Acoustical Sealants & Adhesives ?Outdoor Noise Control ?Assistive Listening Devices
?OSHA, FDA, ADA Compliance ?On-Site Acoustical Analysis ?Acoustical Design & Consulting ?Large Inventory ?Fast Shipment ?No Project too Large or Small ?Major Credit Cards Accepted
|