MATERIAL SAFETY DATA SHEET
EC-RE-016
(Lithium Chloride Reference Electrolyte)
rd
Last updated on 3 September 2008
EUTECH INSTRUMENTS PTE LTD.
Blk 55, Ayer Rajah Crescent, #04-16/24, Singapore 139949
Tel: (65) 6778 6876, Fax: (65) 6773 0836
Website: http://www.eutechinst.com
E-mail: eutech@thermofisher.com
This information is believed to be accurate and represents the best information currently available to us. However, we
make no warranty of merchantability, or fitness for any particular use, or any other warranty, express or implied, with
respect to this information, and we assume no liability resulting from the use of this information. Users should make
their own investigations to determine the suitability of the information for their particular needs and purposes.
GENERAL INFORMATION
PRODUCT NAME: EC-RE-016
MANUFACTURE'S NAME: Eutech Instrument PTE LTD
DISTRIBUTED BY: Eutech Instrument PTE LTD
CHEMICAL NAME: Lithium Chloride in Acetic Acid
CHEMICAL FAMILY: Complex Solution
INGREDIENTS
CAS NO: Lithium Chloride 12125-02-9
CAS NO: Acetic Acid 64-19-7
4.24%
% of : LiCl
% of Acetic Acid 95.76%
25 mg/cm3
OSHA/PEL:
15 ppm
ACGIH/TLV:
LD50(mg/kg) oral-rat of: LiCl 4 3310mg/kg
PHYSICAL DATA
Appearance & Odor: Liquid, Colorless & Pungent, vinegar-like, sour (strong)
Physical State: Liquid
Lowest known value is 1000C . Average weighted: 116.290C
Boiling Point:
Highest known value is 2.3kPa (@ 200C). Average weighted:
Vapour Pressure
1.58kPa (Air = 1)
Freezing Point: NA
Vapour Density: Highest known value is 2.07 (Air=1) Average weighted: 1.92
(Air=1)
Specific Gravity: 105 ( Water = 1)
Solubility: NA
pH: Acidic
Environmental Instruments Division Eutech Instruments Pte Ltd (65) 6778-6876 (8 Lines) Company Registration No. www.thermofisher.com
Water Analysis Instruments Blk 55, Ayer Rajah Crescent (65) 6773-0836 Fax 199606802C
#04-16/24, Singapore 139949
Page 1 of 4 MSDS#: MSDS-ELE-004 Rev 0
FIRE AND EXPLOSION HAZARD DATA
Lowest known value is CLOSED CUP: 390C. OPEN CUP: 430C
Flash Point:
4630C
Auto ignition Temperature:
Fire Extinguishing Media: Flammable liquid, soluble or dispersed in water.
SMALL FIRE: Use DRY chemical powder.
LARGE FIRE: Use alcohol foam, water spray or fog. Cool
containing vessels with water jet in order to prevent pressure
build-up, autoignition or explosion.
Special Fire-fighting procedures: Reacts with metals to produces flammable hydrogen gas. It
will ignite on contact with potassium-tert-butoxide. A mixture
of ammonium nitrate and acetic acid ignites when warmed,
especially if warmed.
Unusual Fire and Explosion Hazards: Acetic acid vapors may foam explosive mixtures with air.
Reactions between acetic acid and the following materials are
potentially explosive: 5-azidotetrazole, bromine pentaflouride,
chromium trioxide and acetic acid is very violent, sometimes
explosive.
Dilute acetic acid and dilute hydrogen can undergo an
exothermic reaction if heated, forming peracetic acid which is
explosive at 110 degree C
Reaction between chlorine triflouride and acetic acid is very
violent, sometimes explosive.
HEALTH HAZARD DATA
Effects of Overexposure: NA
Skin : Wash with soap and water. Cover the irritated skin with an
emollient. Get medical attention if irritation develops. Cold
water may be used
Eyes Check for and remove any contact lenses. In case of contact,
immediately flush eyes with plenty of water for at least
15mins. Cold water may be used. Get medical attention if
irritation occurs..
Ingestion/Inhalation: If inhaled, remove to fresh air. If not breathing, give artificial
respiration. If breathing is difficult, give oxygen. Get medical
attention immediately.
DO NOT induce vomiting unless directed to do so by medical
personnel. Never give anything by mouth to an unconscious
person. Loosen tight clothing such as collar, tie, belt or
waistband.
Serious Ingestion Medical conditions Aggravated by Exposure:
Persons with pre-existing kidney, respiratory, eye, or
neurological problems might be more sensitive to Ethylene
Glycol.
Notes to Physician:
1. Support vital functions, correct for dehydration and shock,
and manage fluid balance.
2. The currently recommended medical management of
Ethylene Glycol and metabolites. Elimination of Ethylene
Glycol may be achieved by the following methods:
a. Emptying the stomach by gastric lavage. It is useful if
initiated within < 1 of ingestion.
b. Correct metabolic acidosis with intravenous administration
of sodium bicarbonate, adjusting the administration rate
according to repeated and frequent measurement of
Environmental Instruments Division Eutech Instruments Pte Ltd (65) 6778-6876 (8 Lines) Company Registration No. www.thermofisher.com
Water Analysis Instruments Blk 55, Ayer Rajah Crescent (65) 6773-0836 Fax 199606802C
#04-16/24, Singapore 139949
Page 2 of 4 MSDS#: MSDS-ELE-004 Rev 0
acid/base status.
c. Administer ethanol (orally or by IV (intravenously)) or
fomepizole (4-methylpyrazole or Antizol)) therapy by IV as an
antidote to inhibit the ormation of toxic metabolite
d. If patients are diagnosed and treated early in the course
with the above methods, hemodialysis may be avoided if
fomepizole or ethanol therapy is effective and has corrected
the metabolic acidosis, and no renal failure is present.
However, once severe acidosis and real failure occurred,
however, hemodialysis is necessary. It is effective I removing
Ethylene Glycol and toxic metabolite, and correcting
metabolic acidosis.
REACTIVITY DATA
Stability: Stable
Condition to avoid: Excess heat, incompatible materials
Incompatibles: Reactive with oxidizing agents, acids, alkalis
Special remarks on reactivity Hygroscopic. Absorbs moisture from air. Avoid contamination
with materials with hydroxyl compounds. Also incompatible
with aliphatic amines, isocyanates, chlorosulfonic acid, and
oleum, potassium hydroxide, sodium hydroxide, phosphorus
isocyanate, ethylenediamine, thylene imine.
Hazardous polymerization: Will not occur
SPILL AND DISPOSAL PROCEDURES
Steps to be taken in the events of a spill or Dilute with water and mop up, or absorb with an inert dry
discharge: material and place in an appropriate waste disposal
container. If necessary: Neutralize the residue with a dilute
solution of sodium carbonate
Disposal procedure: Dispose in accordance with all applicable federal, state and
local environmental regulations
Ventilation: None
Respiratory protection: Approved vapor respirator
Eye/Skin protection: Splash glasses / Lab coat
STORAGE AND HANDLING PRECAUTIONS
Storage requirements: Store on segregated and approved area. Keep container in a
cool, well-ventilated area. Keep container tightly closed and
sealed until ready to use. Avoid all possible sources of
ignition (spark or flame). Do not store above 240C
Environmental Instruments Division Eutech Instruments Pte Ltd (65) 6778-6876 (8 Lines) Company Registration No. www.thermofisher.com
Water Analysis Instruments Blk 55, Ayer Rajah Crescent (65) 6773-0836 Fax 199606802C
#04-16/24, Singapore 139949
Page 3 of 4 MSDS#: MSDS-ELE-004 Rev 0
TRANSPORTATION DATA AND ADDITIONAL INFORMATION
Domestic (D.O.T.)
Proper shipping name: Class 8:Corrosive material
Class 3: Flammable liquid
International (I.M.O.)
Proper shipping name: N/A (Not Regulated for Shipping)
Marine pollutants: Acid
Air (I.C.A.O.)
Proper shipping name: N/A (Not Regulated for Shipping)
Copyright ?2008 Eutech Instruments Pte Ltd. eutech@thermofisher.com
Environmental Instruments Division Eutech Instruments Pte Ltd (65) 6778-6876 (8 Lines) Company Registration No. www.thermofisher.com
Water Analysis Instruments Blk 55, Ayer Rajah Crescent (65) 6773-0836 Fax 199606802C
#04-16/24, Singapore 139949
Page 4 of 4 MSDS#: MSDS-ELE-004 Rev 0
|