ETHYLENE GLYCOL 39.4ppm ceil ar None
100mg/m3 ceil a
3. HAZARDS IDENTIFICATION
Toxicity: Liquid is an eye and skin irritant.
Vapors may irritate eye, nose and throat.
Estimated oral LD50 more than 5000 mg/kg.
Estimated dermal LD50 more than 2000 mg/kg.
Primary Routes of Entry: None known
LOCTITE CORPORATION 09/11/96
ROCKY HILL, CONNECTICUT 06067
EMERGENCY PHONE: (860) 571-5100
Signs and symptoms
of Exposure: Irritation of eyes, skin , nose or throat. May
cause dermatitis on,prolonged contact in sensitive
individuals.
Existing Conditions
Aggravated by Exposure: Acrylic acid: Upper respiratory and lung diseases.
Literature Referenced Carcinogen
Ingredients Target Organ and Other Health Effects NTP IARC OSHA
Polyurethane methacrylate No Data NO NO NO
Polyglycol dimethacrylate ALG IRR NO NO NO
SILICA, AMORPHOUS TREATED NUI NO N/A NO
ACRYLIC ACID ALG COR IRR NO N/A NO
CUMENE HYDROPEROXIDE ALG CNS COR IRR MUT NO NO NO
ETHYLENE GLYCOL AC4 CNS DEV IRR KID MET NO NO NO
1-Acetyl-2-phenylhydrazine ALG NO NO NO
SACCHARIN No Data YES 2B NO
-------------------------------------------------------------------------------
Abbreviations
N/A Not Applicable 2B Possibly carcinogenic to humans
AC4 ACGIH-Unclassifiable as human carc. ALG Allergen
CNS Central nervous system COR Corrosive
DEV Developmental IRR Irritant
KID Kidney MET Metabolic
MUT Mutagen NUI Nuisance dust
4. FIRST AID MEASURES
Ingestion: Do not induce vomiting. Keep individual calm.
Obtain medical attention.
Inhalation: Remove to fresh air. If symptoms persist, obtain
medical attention.
Skin Contact: Wash thoroughly with soap and water
Eye Contact: Flush at least 15 minutes with water. Obtain
medical attention.
5. FIRE FIGHTING MEASURES
Flash Point: More than 200癋 Method: Tag Closed Cup
Recommended
Extinguishing Agents: Carbon dioxide, foam, dry chemical
Hazardous Products formed
by Fire or Thermal Decomp Irritating organic vapors.
LOCTITE CORPORATION 09/11/96
ROCKY HILL, CONNECTICUT 06067
EMERGENCY PHONE: (860) 571-5100
Explosive Limits:
(% by volume in air)Lower 2.0% Acrylic acid
(% by volume in air)Upper 8.0% Acrylic acid
6. ACCIDENTAL RELEASE MEASURES
Steps to be taken in case
of spill or leak: Scrape up as much as possible and store in a
partly filled, closed container until disposal.
Residues may be cleaned up with solvent.
7. HANDLING AND STORAGE
Safe Storage: Store below 100 deg. F
(Contact Loctite Customer Service 1-800-243-4874 for shelf Life information)
Handling: Avoid skin and eye contact. Avoid breathing vapor
8. EXPOSURE CONTROLS, PERSONAL PROTECTION
Eyes: Safety glasses or goggles.
Skin: Rubber or plastic gloves.
Ventilation: Sufficient to maintain vapor concentration below
TLV
See Section 2 for Exposure Limits.
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance: Red gel
Odor: Mild
Boiling Point: More than 300癋
pH: Does not apply
Solubility in Water: Low
Specific Gravity 1.1 at 80癋
Volatile Organic Compound
(EPA Method 24) 13.0%; 143 grams per liter
Vapor Pressure: Less than 5mm at 80癋
Vapor Density: Not available
Evaporation Rate
(Ether = 1) Not available
LOCTITE CORPORATION 09/11/96
ROCKY HILL, CONNECTICUT 06067
EMERGENCY PHONE: (860) 571-5100
Stability: Stable
Hazardous Polymerization: Will not occur
Incompatibility: None
Hazardous Decomposition
Products (non-thermal): None
11. TOXICOLOGICAL INFORMATION
See Section 3.
12. ECOLOGICAL INFORMATION
No data available
13. DISPOSAL CONSIDERATIONS
Recommended methods of
disposal: Incinerate following EPA and local regulations.
EPA Hazardous Waste
Number NH - Not a RCRA Hazardous Waste Material
14. TRANSPORT INFORMATION
DOT (49 CFR 172)
Domestic Ground Transport
Proper Shipping Name: Unrestricted
Hazard Class or
Division: Unrestricted
Identification Number: None
Marine Pollutant: None
IATA
Proper Shipping Name: Unrestricted
Class or Division: Unrestricted
UN or ID Number: None
15. REGULATORY INFORMATION
CA Proposition 65: WARNING: This product contains chemicals known to
the State of California to cause cancer
and birth defects or other reproductive
harm.
Ethylene Oxide
This product contains Saccharin. No Prop65 hazard
warning is necessary if this product is used as
reasonably anticipated.
LOCTITE CORPORATION 09/11/96
ROCKY HILL, CONNECTICUT 06067
EMERGENCY PHONE: (860) 571-5100