Triamcinolone Acetonide Tablets (NADA 137-694)
Material Safety Data Sheet
DOT HCS Risk Phrases Protective Clothing
Not an HCS controlled material in
USA
Trap-N-A-Sak (Bulk)
Section 1: Product Identification and Uses
Common/Trade
Triamcinolone Acetonide Tablets (NADA 137-
name
CI# Not available
694)
Synonyms Triamcinolone Acetonide Tablets TSCA TSCA inventory:
No products were found.
Chemical name Not available CAS# Not applicable
Chemical formula Not available Code MSDS ID#: P137-694
Chemical family Glucocorticoid Molecular Not available
weight
Manufacturer Boehringer Ingelheim Vetmedica, Inc.
Supplier Boehringer Ingelheim Vetmedica, Inc. 2621 North Belt Hwy
2621 North Belt Hwy St. Joseph MO 64506-2002
St. Joseph MO 64506-2002 816-233-2571
Material uses Potent glucocorticoid effective in the treatment of inflammation and related disorders in dogs and cats. This
product is used for the treatment and management of acute arthritis and allergic and dermatologic disorders.
Section 2: Hazardous Ingredients
Name CAS# % by Weight TLV/PEL LC50 / LD 50
LD50, Oral-Mouse, 5
1)Triamcinolonle 76-25-5 0.5 mg/tablet or 1.5 Not available
gm/kg
Acetonide mg/tablet
Section 3: First Aid Measures
Eye contact IMMEDIATELY flush eyes with running water for at least 15 minutes, keeping eyelids open. COLD water may
be used.
Skin contact NO known EFFECT on skin contact, rinse with water for a few minutes.
Hazardous skin No additional information.
contact
Slight inhalation Allow the victim to rest in a well ventilated area.
Hazardous inhalation No additional information.
Slight ingestion No information available regarding ingestion. Notify physician or Poison Control Center immediately.
Hazardous ingestion Not available
Section 4: Physical Data
Solid tablet (251 embossed on the 0.5 mg tablet,
Physical state and
252 embossed on the 1.5 mg tablet)
appearance
Odor Odorless
PH (1% soln/water) Not available Taste Not available
Odor threshold
Not available Color Pink. (Light.)
Triamcinolone Acetonide Tablets (NADA 137-694)
Volatility Not available
Melting/Sublimation point Not available
Boiling/Condensation point Not available
Specific gravity (Water=1) Not available
Vapor density Not available
Vapor pressure Not available
Water/oil dist. Coeff. Not available
Ionicity (surface active Not available
agent)
Critical temperature Not available
Instability temperature Not available
Conditions of instability No additional remark
Dispersion properties Not available
Solubility Very slightly soluble in cold water, hot water.
Section 5: Fire and Explosion Data
The product is: Not applicable
Auto-ignition Not available
temperature
Fire degradation Toxic and/or noxious fumes may be emitted when burned.
products
Flash points Not available
Flammable limits Not available
Fire extinguishing SMALL FIRE: Use DRY chemicals, CO2, water spray or foam
procedures
LARGE FIRE: Use water spray, fog or foam. DO NOT use water jet. NIOSH approved SCBA and full
protective gear is recommended to fire fighters.
Flammability Not applicable
Risks of explosion Risks of explosion of the product in presence of mechanical impact: Not available.
Risks of explosion of the product in presence of static discharge: Not available.
No specific information is available in our database regarding the product鈥檚 risks of explosion in the presence
of various materials.
Page 2 of 4
Triamcinolone Acetonide Tablets (NADA 137-694)
Section 6: Reactivity Data
Stability The product is stable.
Hazardous decomp. Noxious fumes
products
Degradability Not available
Product of Noxious fumes
degradation
Not available
Corrosivity No specific information is available in our database regarding the corrosivity of this product in the presence
of various materials.
Reactivity No incompatible product according to our data base.
Section 7: Toxicological Properties
Routes of entry Absorbed through skin. Ingestion.
TLV Not available
Not available
Toxicity for animals
Environmental hazards Not available
Chronic effects on humans Carcinogenic Effects: Not available
Mutagenic Effects: Not available
Teratogenic Effects: Not available
Developmental Toxicity: Not available. There is no known effect from chronic exposure to this product.
Repeated or prolonged exposure is not known to aggravate medical condition.
Acute effects on humans Elevated blood pressure, electrolyte imbalances, pituitary-adrenal/suppression, increased susceptibility
to infection, peptic ulcers, weakness in the arms and legs.
Section 8: Preventive Measures
Waste information Dispose of in accordance with all laws.
Waste stream Not available
Storage Store at room temperature in a dry place.
Precautions Keep out of reach to label directions.
Small spill and leak Absorb with an inert material and place in an appropriate waste disposal container.
Large spill and leak No additional information
Protective Clothing Rubber gloves. Safety glasses.
Page 3 of 4
Triamcinolone Acetonide Tablets (NADA 137-694)
Section 9: Classification
DOT Not a DOT controlled material (United States).
Maritime
Not applicable
transportation
Not an HCS controlled material in USA
HCS
Federal and
Not applicable
State
Regulations
HMIS (U.S.A.)
National Fire Protection
Health Hazard 1
Fire Hazard
0
Association (U.S.A.)
Fire Hazard 0
1 0
Reactivity 0
Reactivity
B
Personal Protection
Specific hazard
Section 10: Protective Measures
Protective Gloves, safety glasses
clothing
Engineering Good general ventilation should be sufficient to control airborne levels.
controls
Section 11: Other Information
References Not available
Validated by Company: 3/28/05
CALL: (800) 821-7467
Emergency Medical: (800)530-5432
Chemtrec: (800)424-9300
The information provided herein is offered by Boehringer Ingelheim Vetmedica, Inc. (鈥淏IV鈥?) in good faith as accurate as of the date hereof, but
without guarantee. This information includes information which has been generated by other parties and provided to BIV, and which BIV has
not independently verified. The information provided herein relates only to the specific product designated, and may not be valid where such
product is used in combination with any other materials or in any process. The information provided herein is offered solely for your
consideration, investigation and verification, and Boehringer Ingelheim Vetmedica, Inc. (鈥淏IV鈥?) expressly disclaims all liability for reliance
thereon. BIV EXPRESSLY DISCLAIMS ALL WARRANTIES OF EVERY KIND AND NATURE (INCLUDING WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE) WITH RESPECT TO THE USE OR SUITABILITY OF THE
PRODUCT. In addition, since the conditions of use and suitability of the product for particular uses are beyond BIV鈥檚 control, ALL RISKS OF
USE OF THE PRODUCT ARE THEREFORE ASSUMED BY THE USER, AND BIV EXPRESSLY
DISCLAIMS ANY AND ALL LIABILITY AS TO ANY RESULTS OBTAINED OR ARISING FROM ANY USE OF THE PRODUCT. Use or
retransmission of the information contained herein in any other format than the format as presented is strictly prohibited. Nothing herein shall
be construed as a permission or recommendation for the use of the product in a manner that might infringe an existing patent. BIV neither
represents nor warrants that the format, content or product formulas contained in this document comply with the laws of any other country
except the United States of America.
漏 Copyright 2001 Boehringer Ingelheim Vetmedica, Inc. All rights reserved.
Page 4 of 4
Triamcinolone Acetonide Tablets (NADA 137-694)
Triamcinolone Acetonide Tablets (NADA 137-694)
Trap-N-A-Sak (Bulk)
The information provided herein is offered by Boehringer Ingelheim Vetmedica, Inc. (鈥淏IV鈥?) in
good faith as accurate as of the date hereof, but without guarantee. This information includes
information which has been generated by other parties and provided to BIV, and which BIV has
not independently verified. The information provided herein relates only to the specific product
designated, and may not be valid where such product is used in combination with any other
materials or in any process. The information provided herein is offered solely for your
consideration, investigation and verification, and Boehringer Ingelheim Vetmedica, Inc. (鈥淏IV鈥?)
expressly disclaims all liability for reliance thereon. BIV EXPRESSLY DISCLAIMS ALL
WARRANTIES OF EVERY KIND AND NATURE (INCLUDING WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE) WITH RESPECT
TO THE USE OR SUITABILITY OF THE PRODUCT. In addition, since the conditions of use
and suitability of the product for particular uses are beyond BIV鈥檚 control, ALL RISKS OF USE
OF THE PRODUCT ARE THEREFORE ASSUMED BY THE USER, AND BIV EXPRESSLY
DISCLAIMS ANY AND ALL LIABILITY AS TO ANY RESULTS OBTAINED OR
ARISING FROM ANY USE OF THE PRODUCT.
Use or re-transmission of the information contained herein in any other format than the format as
presented is strictly prohibited. Nothing herein shall be construed as a permission or
recommendation for the use of the product in a manner that might infringe an existing patent.
BIV neither represents nor warrants that the format, content or product formulas contained in this
document comply with the laws of any other country except the United States of America.
漏 Copyright 2001 Boehringer Ingelheim Vetmedica, Inc. All rights reserved.
Disclaimer.doc
|