Material Safety Data Sheet
Responsible Name Pierce Administration
Section 1. Chemical Product and Company Identification
IQTM Kinase Assay Reagent B*, 300 碌L
Common Name
Code 1858725
Supplier Pierce Biotechnology
P.O. Box 117
Rockford, IL 61105
USA
815.968.0747 or
1.800.874.3723
In Case of Emergency CALL CHEMTREC:
800.424.9300
OUTSIDE US:
202.483.7616
Print Date 6/21/2002
Validation Date 6/21/2002
MSDS# 5125 *Patent Pending
Manufacturer Pierce Biotechnology
P.O. Box 117
Rockford, IL 61105
USA
815.968.0747 or
1.800.874.3723
Section 2. Composition and Information on Hazardous (OSHA) Ingredients
Name CAS # % by Weight Exposure Limits
TWA: 1 (mg/m3) from OSHA (PEL) [United States] [2000]**
1) IQ Reagent B Ingredient 1 <50
**This exposure limit is applicable to ingredient in dry form only.
Section 3. Hazards Identification
Review the most current and approved institutional guideline, protocol, standard operating procedure(s)
and MSDS(s) for the proper handling of institutional materials/equipment associated with the use of this
Pierce product.
Emergency Overview DANGER!
CAUSES SEVERE EYE AND SKIN IRRITATION.
CONTAINS MATERIAL WHICH CAUSES DAMAGE TO THE FOLLOWING ORGANS:
MUCOUS MEMBRANES, RESPIRATORY TRACT, SKIN, EYES.
Avoid contact with eyes, skin and clothing. Wash thoroughly after handling.
Routes of Entry Absorbed through skin. Eye contact. Inhalation. Ingestion.
Potential Acute Health Very hazardous in case of skin contact (irritant), of eye contact (irritant). Non-hazardous in case of
Effects ingestion. Non-hazardous in case of inhalation. Corrosive to skin and eyes on contact. Liquid or spray
mist may produce tissue damage particularly on mucous membranes of eyes, mouth and respiratory tract.
Skin contact may produce burns. Inhalation of the spray mist may produce severe irritation of respiratory
tract, characterized by coughing, choking, or shortness of breath. Inflammation of the eye is characterized
by redness, watering, and itching. Skin inflammation is characterized by itching, scaling, reddening, or,
occasionally, blistering.
Carcinogenic Effects Data CARCINOGENIC EFFECTS: Not available.
MUTAGENIC EFFECTS: Not available.
TERATOGENIC EFFECTS: Not available.
Medical Conditions Aggravated Repeated or prolonged contact with spray mist may produce chronic eye irritation and severe skin irritation.
by Overexposure: Repeated or prolonged exposure to spray mist may produce respiratory tract irritation leading to frequent
attacks of bronchial infection.
Continued on Next Page
IQTM Kinase Assay Reagent B*, 300 碌L Page: 2/5
EU Regulations R36/38- Irritating to eyes and skin.
S2- Keep out of the reach of children.
S46- If swallowed, seek medical advice immediately and show this container or label.
Irritant
See Toxicological Information (section 11)
Section 4. First Aid Measures
SKIN: Wash contaminated skin with soap and water.
EYES: Flush with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids.
Seek medical attention.
Inhalation: Move exposed person to fresh air. If irritation persists, get medical attention.
Ingestion: Do not induce vomiting. If affected person is conscious, give plenty of water to drink. Seek
medical attention.
Section 5. Fire Fighting Measures
Flammability of the Product Non-flammable.
Flash Points Not applicable.
Fire Hazards in Presence of Not applicable.
Various Substances
Fire Fighting Media Not applicable.
and Instructions
Protective Clothing (Fire) Not applicable.
Section 6. Accidental Release Measures
Small Spill and Leak Dilute with water and mop up, or absorb with an inert dry material and place in an appropriate waste disposal
container. If necessary: Neutralize the residue with a dilute solution of sodium carbonate.
Large Spill and Leak Corrosive liquid.
Stop leak if without risk. Absorb with DRY earth, sand or other non-combustible material. Do not get water
inside container. Do not touch spilled material. Use water spray curtain to divert vapor drift. Prevent entry
into sewers, basements or confined areas; dike if needed. Call for assistance on disposal. Neutralize the
residue with a dilute solution of sodium carbonate. Be careful that the product is not present at a
concentration level above TLV. Check TLV on the MSDS and with local authorities.
Continued on Next Page
IQTM Kinase Assay Reagent B*, 300 碌L Page: 3/5
Section 7. Handling and Storage
Handling Avoid contact with eyes, skin, and clothing. Wash thoroughly after handling.
Storage Keep container tightly closed. Keep container in a cool, well-ventilated area.
Section 8. Exposure Controls/Personal Protection
Engineering Controls Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors below
Personal Protection their respective threshold limit value.
Splash goggles.
Eyes
Lab coat.
Body
Not applicable.
Respiratory
Gloves.
Hands
Protective Clothing
(Pictograms)
Consult local authorities for acceptable exposure limits.
Section 9. Physical and Chemical Properties
Physical State and Liquid.
Odor Odorless.
Appearance
Molecular Weight Not applicable. Taste Not available.
Color Yellowish.
pH (1% Soln/Water) 2 to 3 [Acidic.]
Boiling/Condensation Point The lowest known value is 100掳C (212掳F) (Milli-Q Water).
Melting/Freezing Point May start to solidify at -0.1掳C (31.8掳F) based on data for: Milli-Q Water.
Specific Gravity Weighted average: 1.02 (Water = 1)
Vapor Pressure The highest known value is 2.3 kPa (@ 20掳C) (Milli-Q Water).
Vapor Density The highest known value is 0.62 (Air = 1) (Milli-Q Water).
Evaporation Rate 0.36 (Milli-Q Water) compared to Butyl acetate.
Dispersion Properties See solubility in water.
Solubility Soluble in cold water, hot water.
Section 10. Stability and Reactivity
Stability and Reactivity The product is stable.
Incompatibility with Various Slightly reactive to reactive with oxidizing agents.
Substances
Hazardous Polymerization Will not occur.
Hazardous Decomposition These products are halogenated compounds.
Products
Continued on Next Page
IQTM Kinase Assay Reagent B*, 300 碌L Page: 4/5
Section 11. Toxicological Information
Other Toxic Effects on Humans Non-hazardous in case of inhalation. Non-irritant for lungs.
Section 12. Ecological Information
Toxicity of the Products of The product itself and its products of degradation are not toxic.
Biodegradation
Section 13. Disposal Considerations
Waste Information Waste must be disposed of in accordance with federal, state and local environmental control regulations.
Waste Stream Not available.
Consult your local or regional authorities.
Section 14. Transport Information
Contact Pierce for all transport information.
Section 15. Regulatory Information
HCS Classification Irritating substance.
U.S. Federal Regulations TSCA 8(b) inventory: Milli-Q Water
SARA 302/304/311/312 extremely hazardous substances: No products were found.
SARA 302/304 emergency planning and notification: No products were found.
SARA 302/304/311/312 hazardous chemicals: No products were found.
SARA 311/312 MSDS distribution - chemical inventory - hazard identification: No products were found.
SARA 313 toxic chemical notification and release reporting: No products were found.
Clean Water Act (CWA) 307: No products were found.
Clean Water Act (CWA) 311: No products were found.
Clean air act (CAA) 112 accidental release prevention: No products were found.
Clean air act (CAA) 112 regulated flammable substances: No products were found.
Clean air act (CAA) 112 regulated toxic substances: No products were found.
WHMIS (Canada) CLASS E: Corrosive liquid.
CEPA DSL: Milli-Q Water
International Regulations
EINECS Not available.
DSCL (EEC) R36/38- Irritating to eyes and skin.
International Lists Australia (NICNAS): Milli-Q Water
Korea (TCCL): Milli-Q Water
Philippines (RA6969): Milli-Q Water
State Regulations No products were found.
California prop. 65: No products were found.
Continued on Next Page
IQTM Kinase Assay Reagent B*, 300 碌L Page: 5/5
Section 16. Other Information
Hazardous Material Health National Fire Protection
* 2 Fire Hazard
Information System (U.S.A.) Association (U.S.A.) 0
0
Fire Hazard
2 0
Health Reactivity
0
Reactivity
Specific Hazard
Personal Protection
Validated by Pierce Administration on 6/21/2002. Verified by Pierce Administration.
Printed 6/21/2002.
Notice to Reader
To the best of our knowledge, the information contained herein is accurate. However, neither the above named supplier nor any of its subsidiaries
assumes any liability whatsoever for the accuracy or completeness of the information contained herein.
Final determination of suitability of any material is the sole responsibility of the user. All materials may present unknown hazards and should be used
with caution. Although certain hazards are described herein, we cannot guarantee that these are the only hazards that exist.*Patent Pending
|