Material Safety Data Sheet
Trade name: ALEXSEAL-Fairing Compound 202 Converter C2075
Status: 3/19/2009
Product no.: 1552078403 Version: 3.0.0 / USA
1.) Identification of the substance/preparation and of the
company/undertaking
Identification of the substance or preparation
Trade name
ALEXSEAL-Fairing Compound 202 Converter C2075
Company/undertaking identification
Address
Mankiewicz Coatings L.L.C
831 South 21st Street
St. Louis, Missouri 63103
USA
Telephone no. +1 314 783-2110
Emergency telephone
CHEMTREC: 800-424-9300 OR 703-527-3887
2.) Hazards identification
Immediate hazards
General
DANGER
Causes:
skin and eye burns.
May cause allergic skin reaction.
Harmful if inhaled.
May be harmful if absorbed through skin or swallowed.
Potential environmental effects
Toxic to fish and other water organisms.
Potential Health Effects
Eye
Causes: eye burns
Skin
Causes: skin burns; May cause: Allergic skin reaction; May be harmful if absorbed through skin.
Inhalation
Harmful if inhaled. May cause respiratory tract irritation.
Ingestion
May be harmful if swallowed.
Cancer
None of the components present in this material at concentrations equal or greater than 0.1% is listed
by IARC, NTP, OSHA or ACGIH as a carcinogen.
3.) Composition / information on ingredients
Hazardous ingredients
BENZYL ALCOHOL
CAS no. 100-51-6
Concentration > 10 < 30 %-b.w.
3,6,9-TRIAZAUNDECAMETHYLENEDIAMINE
CAS no. 112-57-2
Concentration > 1 < 5 %-b.w.
m-PHENYLENEBIS(METHYLAMINE)
CAS no. 1477-55-0
Concentration > 1 < 5 %-b.w.
Mankiewicz Coatings LLC
page: 1(2)
Material Safety Data Sheet
Trade name: ALEXSEAL-Fairing Compound 202 Converter C2075
Status: 3/19/2009
Product no.: 1552078403 Version: 3.0.0 / USA
POLY(METHYLENECYCLOHEXYLAMINE)
CAS no. 135108-88-2
Concentration > 30 < 50 %-b.w.
4.) First aid measures
General information
In all cases of doubt, or when sickness symptoms persist, seek medical attention. Never give anything
by mouth to an unconscious person.
After inhalation
Remove to fresh air, keep patient warm and at rest. Irregular breathing/no breathing: artificial
respiration. If unconscious place in recovery position and seek medical advice.
After skin contact
Wash skin thoroughly with soap and water or use recognised skin cleaner. Do NOT use solvents or
thinners !
After eye contact
Remove contact lenses, irrigate copiously with clean, fresh water for at least 10 minutes, holding the
eyelids apart and seek medical advice.
After ingestion
When swallowed seek medical aid immediately and show the physician the packaging or the label of
the packaging. Do not induce vomiting.
5.) Firefighting measures
Suitable extinguishing media
Alcohol resistant foam, CO2, powders, water spray
Extinguishing media that must not be used for safety reasons
Full water jet
Special exposure hazards arising from the substance or preparation itself, its combustion
products or from resulting gases
Fire will produce dense black smoke. Exposure to decomposition products may cause a health hazard.
Special protective equipment for firefighting
As in any fire, wear self-contained breathing apparatus pressure - demand, MSHA/ NIOSH (approved
or equivalent) and full protective gear.
Other information
Cool endangered containers with water in case of fire. Do not allow run-off from firefighting to enter
drains or water courses.
6.) Accidental release measures
Personal precautions
Exclude sources of ignition and ventilate the area. Do not inhale vapours. Refer to protective measures
listed in sections 7 and 8.
Environmental precautions
Do not allow to enter drains. If the product contaminates lakes, rivers or sewage, inform appropriate
authorities in accordance with local regulations.
Methods for cleaning up/taking up
Contain and collect spillage with non-combustible absorbent materials, e.g. sand, earth, vermiculite,
diatomaceous earth and place in suitable container for disposal. Clean preferably with a detergent;
avoid use of solvents.
Mankiewicz Coatings LLC
page: 2(2)
Material Safety Data Sheet
Trade name: ALEXSEAL-Fairing Compound 202 Converter C2075
Status: 3/19/2009
Product no.: 1552078403 Version: 3.0.0 / USA
7.) Handling and storage
Handling
Advice on safe handling
Prevent the creation of flammable or explosive concentrations of vapour in air and avoid vapour
concentrations higher than the occupational exposure limits. The product should only be used in areas
from which all naked lights and other sources of ignition have been excluded. Take precautionary
measures against electrostatic loading. Refer to protective measures listed in section 8. Comply with
the health and safety at work laws.
Advice on protection against fire and explosion
Vapors are heavier than air and may spread along floors. Vapors may form explosive mixtures with air.
Storage
Requirements for storage rooms and vessels
Electrical equipment should be protected to the appropriate standard. Floors should be of the
conducting type. Keep container tightly closed. Never use pressure to empty: container isnot a
pressure vessel. No smoking. Prevent unauthorized access. Containers which are opened must be
carefully resealed and kept upright to prevent leakage.
Hints on storage assembly
Keep away from oxidizing agents, from strongly alkaline and strongly acid materials.
Further information on storage conditions
Always keep in containers of same material as the original one. See also instructions on the label.
Avoid heating and direct sunlight. Keep container in a cool, well-ventilated place.
8.) Exposure controls / personal protection
Exposure limit values
m-PHENYLENEBIS(METHYLAMINE)
CAS no. 1477-55-0
EC no. 216-032-5
ACGIH
m-Xylene a,a'-diamine
Ceiling Limit 0.1 mg/m?br>
Skin resorption / Skin
sensibilisation
Exposure controls
Occupational exposure controls
Provide adequate ventilation. Where reasonably practicable this should be achieved by the use of local
exhaust ventilation and good general extraction. If these are not sufficient to maintain concentrations
of particulates and solvent vapour below the OEL (=Occupational ExposureLimit), suitable respiratory
protection must be worn.
Personal protective equipment
Respiratory protection
If workers are exposed to concentrations above the exposure limit they must use appropriate, certified
respirators. Use NIOSH/MSHA approved dust respirator if concentation exceeds recommended
exposure levels.
Hand protection
Glove permeation data does not exist for this material. The following glove(s) should be used for
splash protection only.
Appropriate Material nitrile
Eye protection
Use chemical splash goggles and face shield (ANSI Z87.1 or approved equivalent).
Mankiewicz Coatings LLC
page: 3(3)
Material Safety Data Sheet
Trade name: ALEXSEAL-Fairing Compound 202 Converter C2075
Status: 3/19/2009
Product no.: 1552078403 Version: 3.0.0 / USA
Skin protection
fire-resistant antistatic protective clothing
General protective and hygiene measures
Remove soiled or soaked clothing immediately. Avoid the inhalation of dust from sanding, particulates
and spray mist arising from the application of this preparation. Do not eat, drink or smoke during work
time.
9.) Physical and chemical properties
General information
Form Pasty
Color various colour shades
Odor amine-like
Important health, safety and environmental information
Changes in physical state
Type Starts to boil
Value 401 癋
Pressure 1013 mbar
Flash point
Value 266 癋
self ignition
Value not applicable
Density
Value 5.81 lbs/gallon
Reference temperature 68 癋
Viscosity
Type Efflux time
Value > 150 s
Method DIN cup 4 mm
Solubility in water
Remarks insoluble
10.) Stability and reactivity
Conditions to avoid
Stable under recommended storage and handling conditions(See section 7).
Materials to avoid
Keep away from oxidizing agents, strongly alkaline and strongly acid materials in order to avoid
exothermic reactions.
Hazardous decomposition products
When exposed to high temperatures may produce hazardous decomposition products such as carbon
monoxide and dioxide, smoke, oxides of nitrogen.
11.) Toxicological information
Irritant/corrosive effects
Irritant effect on skin
Evaluation corrosive
Irritant effect on eyes
Evaluation corrosive
Experience in practice
Possibility of sensitization through skin contact.
Mankiewicz Coatings LLC
page: 4(4)
Material Safety Data Sheet
Trade name: ALEXSEAL-Fairing Compound 202 Converter C2075
Status: 3/19/2009
Product no.: 1552078403 Version: 3.0.0 / USA
12.) Ecological information
Other adverse effects
There are no data available on the preparation itself.
13.) Disposal considerations
Product
Dispose in accordance with federal, state and local regulations.
14.) Transport information
US DOT
Class 8
Packaging group II
Label 8
UN/NA number UN3259
Technical name Polyamines, solid, corrosive, n.o.s.
Danger releasing substance m-phenylenebis(methylamine)
POLY(METHYLENECYCLOHEXYLAMINE)
Marine transport IMDG
Class 8
Packaging group II
UN number 3259
Proper shipping name Polyamines, solid, corrosive, n.o.s.
Danger releasing substance m-phenylenebis(methylamine)
POLY(METHYLENECYCLOHEXYLAMINE)
EmS F-A,S-B
Label 8
Air transport ICAO/IATA
Class 8
Packaging group II
UN number 3259
Proper shipping name Polyamines, solid, corrosive, n.o.s.
Danger releasing substance m-phenylenebis(methylamine)
POLY(METHYLENECYCLOHEXYLAMINE)
Label 8
Mankiewicz Coatings LLC
page: 5(5)
Material Safety Data Sheet
Trade name: ALEXSEAL-Fairing Compound 202 Converter C2075
Status: 3/19/2009
Product no.: 1552078403 Version: 3.0.0 / USA
15.) Regulatory information
Regulations
US Federal Regulations
TSCA (Toxic Substances Control Act)
All of the components of this product are either listed on the TSCA Inventory or are not subject to the
notification requirements (exempt).
Clean Water Act (CWA)
None of the ingredients is listed.
Clean Air Act
None of the ingredients is listed.
OSHA: Hazardous by definition of Hazard Communication Standard ( 29 CFR 1910.1200)
Following ingredients are Hazardous by definition of Hazard Communication Standard:
CAS-No. 100-51-6; 112-57-2; 135108-88-2; 1477-55-0
SARA Section 302 (RQ):
None of the ingredients is listed.
SARA HAZARD CATEGORY (Section 311/312)
Acute Health Hazards
SARA Section 313
None of the ingredients is listed.
HAPS (Hazardous Air Pollutants) according to Clean Air Act
None of the ingredients is listed.
State Regulations
California Proposition 65.
None of the ingredients is listed.
Pennsylvania HAZARDOUS SUBSTANCE LIST
Following ingredients are listed:
CAS-No. 100-51-6; 112-57-2; 1477-55-0
New Jersey Worker and Community Right to Know Act.
Following ingredients are listed:
CAS-No. 112-57-2
Other international listings
IARC
None of the ingredients is listed in group 1, 2A or 2B.
Volatile organic compounds (VOC)
pound/gallon 0.72
16.) Other information
HMIS Classification
Health 2
Flammability : 1
Reactivity 0
PPE E
NFPA Rating
Health 2
Fire Hazard 1
Reactivity 0
Mankiewicz Coatings LLC
page: 6(6)
Material Safety Data Sheet
Trade name: ALEXSEAL-Fairing Compound 202 Converter C2075
Status: 3/19/2009
Product no.: 1552078403 Version: 3.0.0 / USA
Other information
Abbreviations:
ACGIH American Conference of Governmental Hygienics
CAS Chemical Abstracts Service
HAPS Hazardous Air Pollutants
HMIS Hazardous Material Identifikation System
IARC International Agency for Research on Cancer
IDLH Immediate Dangerous to Life and Health
LEL Lower Explosion Limit
NTP National Toxicology Program
OEL Occupational Exposure Limit
OSHA Occupational Safety and Health Administration
PEL Permissible Exposure Limit
PPE Personal Protection Equipment
SARA Superfund Amendments and Reauthorization Act
STEL Short-Term Exposure Level (15 minutes)
TWA Time-Weighted Average (8 hours)
UEL Upper Explosion Limit
VOC Volatile Organic Compounds
WEEL Workplace Environmental Exposure Level
Department issuing safety data sheet
UMCO Umwelt Consult GmbH
Georg-Wilhelm-Str. 183 b, D-21107 Hamburg, Germany
Tel.: +49 40 / 41 92 13 00 Fax: +49 40 / 41 92 13 57 e-mail: umco@umco.de
This information is based on our present state of knowledge. However, it should not constitute a
guarantee for any specific product properties and shall not establish a legally valid relationship.
Mankiewicz Coatings LLC
page: 7(7)
|