Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

121-82-4 3964-18-9 7429-90-5 7439-92-1

File Name: 121-82-4_3964-18-9_7429-90-5_7439-92-1.asp

`

Accurate Energetic Systems, LLC

MATERIAL SAFETY DATA SHEET

BI-DI (Bidirectional Destruct Charge)
MSDS NO. 1004.003

HAZARD RATING: Health - 2 Flammability - 3 Reactivity - 4 Special - High Explosive




SECTION I - MANUFACTURE'S INFORMATION
Manufacture/Distributor Name: Accurate Energetic Systems, LLC
Address: 5891 Highway 230 West, McEwen, TN 37101
Telephone Number: (931) 729-4207
Emergency Telephone Number: 1-800-255-3924
Date Prepared: 04/25/01 Supercedes: 12/13/99




SECTION II - CHEMICAL COMPOSITION
Component CAS # % OSHA PEL ACGIH TLV Other Limits
0.5 mg/m3 TWA 1.5 mg/m3 NIOSH TWA
RDX 121-82-4 89.9% - 92.0% n/a
3.0 mg/m3 STEL; skin
(cyclotrimethylene trinitramine; hexogen; cyclonite) skin
Polyisobutylene 2.1% - 2.5% n/a n/a n/a
Dioctyl Adipate (DOA) or 5.3% - 5.9% n/a n/a n/a
Dioctyl Sebacate (DOS)
Petroleum Oil 1.4% - 1.6% n/a n/a n/a
Identifiers: 0.5% - 2.0%
DMDNB 3964-18-9 n/a n/a 1.5 mg/m3 PEL*
(2,3-dimethyl-2,3-dinitrobutane)
(* established by United States Army Center for Health Promotion and Preventive Medicine (USACHPPM)
MNT n/a n/a n/a
(ortho-mononitrotoluene)
15 mg/m (total dust) 10 mg/m3-metal dust
3
10 mg/m3(total dust)
Aluminum (casing) 7429-90-5
5 mg/m3(resp.fract) 5 mg/m3(resp.fract)
- metal dust - metal dust; NIOSH
Steel (casing) n/a n/a n/a
0.05 mg/m3 0.05 mg/m3 <0.1 mg/m3 -NIOSH
Lead (liner) 7439-92-1


NOTE: Hazard Class 1, Division 1; SCG "D"

NOTE: Materials in this product are subject to the reporting requirements of SARA, Title III, Section 313 as follows:
Aluminum (fume or dust); lead



SECTION III - PHYSICAL AND CHEMICAL DATA (NOTE: Data is for Composition C-4 only except
for "Appearance and Odor"

Boiling Point: n/a
Specific Gravity: 1.7
1900-2000C (RDX)
Melting Point:
4.08 X 10-4 @ 1100C (RDX)
Vapor Pressure (mm Hg):

MSDS NO. 1004.003 Page 1 of 4
`
SECTION III - PHYSICAL AND CHEMICAL DATA (cont.)
Vapor Density (Air = 1): n/a
Evaporation Rate (Butyl Acetate = 1): n/a
Solubility In Water: Insoluble
Appearance And Odor: Explosive charge encased in a thin circular metallic case with no
distinguishing odor.




SECTION IV - FIRE AND EXPLOSION HAZARDS
Flash Point: n/a
Flammable Limits: LEL n/a UEL n/a
Extinguishing Media: Water sprinkler or deluge system which is automatically activated.
Special Fire Fighting Procedures:
Do not attempt to fight fires involving high explosives. Isolate area and immediately evacuate all personnel from
the area to a safe distance using as much protective cover as possible.
Unusual Fire And Explosion Hazards:
HIGH EXPLOSIVE!! The explosive material is under confinement and may be caused to detonate by burning
material surrounding the charge. Metallic fragments are a secondary hazard.




SECTION V - REACTIVITY/COMPATIBILITY DATA
Stability:
Stable under normal conditions. High heat, shock, impact, electrical discharge when supplied in sufficient energy
may cause the charge to detonate.
Incompatibility (materials to avoid):
Alkalis and acids which may react with the metallic casing. In case of exposure to explosive material: Avoid
alkalis, acids, initiating explosives, and physical sensitizers such as glass, sand, and metal fragments.
Hazardous Decomposition Products:
During decomposition, emits toxic oxides of nitrogen.
Hazardous Polymerization:
Will not occur




SECTION VI - HEALTH HAZARD DATA
NOTE: Under normal conditions of handling, personnel should not come in contact with the explosive material in the
charge. The metallic casing should not pose a serious health threat except possibly through post-detonation fumes.

Routes Of Entry:
Eye? Unlikely
Inhalation? Yes (post-detonation fumes)
Skin? Unlikely
Ingestion? Yes (post-detonation fumes)
Effects Of Over-Exposure:
Acute - Slight to serious effects
Chronic - Not fully known




MSDS NO. 1004.003 Page 2 of 4
`
SECTION VI - HEALTH HAZARD DATA (cont.)
Signs And Symptoms Of Exposure:
Post-detonation fumes are toxic. NOTE: The following information is for the explosive material. Can cause
allergic skin reaction and eye irritation. Excessive exposure may cause convulsions, unconsciousness. Inhalation
and ingestion can result in systemic poisoning, usually affecting the bone marrow and the liver. The
polyisobutylene, DOA or DOS, and petroleum oil components of this material are not expected to present any
significant health effects.
Medical Conditions Generally Aggravated By Exposure:
Personnel should be in generally good health
Emergency First Aid Procedures:
Eye - Flush with water for 15 minutes. Remove contact lenses prior to flushing, if applicable. Get
medical attention.
Inhalation - Remove to fresh air. Give oxygen if necessary. Get medical attention.
Skin - Wash with soap and warm water. Get medical attention for rash or irritation.
Ingestion - If conscious, drink large quantities of water and induce vomiting immediately. Contact a
physician or Poison Control Center immediately.
Other - Accidental detonation may result in severe personal injury. Provide first aid as applicable and
obtain medical attention immediately.
Carcinogenicity:
NTP? Not listed
IARC Monographs? Not listed
OSHA Regulated? Not listed
NOTE: Per EPA-C: cyclonite - possible human carcinogen



SECTION VII - PRECAUTIONS FOR SAFE HANDLING AND USE
Steps To Follow If Material Is Spilled Or Released:
Should not occur due to the fact that the charge is a completely sealed unit. In case of extreme situation whereas
the explosive material is exposed, remove all sources of ignition and avoid any and all situations which could
initiate the material, such as friction, impact, heat, sparks, or electrostatic discharge. Wet down material with
water. Sweep up spill with a soft bristle brush and a non-sparking pan or shovel. Place material in a properly
labeled storage container and store in an approved storage magazine for further disposition.
Waste Disposal Method:
Dispose of in accordance with applicable local, state, and federal regulations.
Precautions To Be Taken In Handling And Storage:
Handle with care. Store only in authorized High Explosives magazine with compatible material and away from all
sources of ignition and flammable materials. Do not store with detonators, initiating explosives, or any other
material which could react with the metallic casing.
Other Precautions:
The bi-directional destruct charge is UNO Class 1.1 hazardous material and the storage compatibility group (SCG)
is D. Material should remain in original shipping container or equivalent for storage purposes.



SECTION VIII - PERSONAL PROTECTION INFORMATION
Respirator Protection (Specify Type):
Under normal handling, none required.
Ventilation:
Local Exhaust - Under normal handling, none required.
Mechanical (General) - Under normal handling, none required.
Special - n/a
Other - n/a

MSDS NO. 1004.003 Page 3 of 4
`
SECTION VIII - PERSONAL PROTECTION INFORMATION (cont.)
Protective Gloves:
Under normal handling, none required.
Eye Protection:
Safety glasses or goggles that meet or exceed ANSI Z87.1 (latest revision)
Other Protective Clothing Or Equipment:
Hearing protection should be worn during test firings.
Work/Hygienic Practices:
n/a



SECTION IX - SPECIAL PRECAUTIONS
Precautions To Be Taken:
CAUTION: High explosives are extremely dangerous. When initiated, the charge detonates producing a severe
blast overpressure with high velocity metallic fragments being generated along with secondary fragments from the
surface which the charge is placed against. The charge should be handled only by qualified personnel who are
experienced and highly trained in the use of and familiar with the hazards inherent with this charge. When the
charge is detonated or destructively tested, all personnel must be protected from the effects of blast overpressure
and fragmentation. Allow the post-detonation fumes and dust to clear prior to entering the area. Follow all safety
regulations and precautions when handling, storing, or utilizing explosive material.



The information contained herein is believed to be accurate and represents the best information currently available.
Accurate Energetic Systems, LLC makes no warranties or guarantees with respect to the safety or suitability of this
product or the results obtained, either expressed or implied. Buyer and user assume any and all risk, responsibility,
and liability for any and all injury (including death), loss, or damage arising from usage.




MSDS NO. 1004.003 Page 4 of 4

Search    ENTER KEYWORD
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
3937-56.asp 3937-56-2
395-33-5.asp 395-33-5
3952-78-1.asp 3952-78-1
44-20-8_58-93-5_396-01.asp 44-20-8 58-93-5 396-01-0
78-11-5_9004-70-0_77-90-7_3964-18-9.asp 78-11-5 9004-70-0 77-90-7 3964-18-9
121-82-4_3964-18-9_7429-90-5_7439-92-1.asp 121-82-4 3964-18-9 7429-90-5 7439-92-1
3992-42.asp 3992-42-5
4005-49-6.asp 4005-49-6
401-81-0.asp 401-81-0
1022786812.asp N/A
404-86-4_57-55-6.asp 404-86-4 57-55-6
8042-47-5_64-17-5_67-63-0_9010-79-1_404-86-4.asp 8042-47-5 64-17-5 67-63-0 9010-79-1 404-86-4
7727-37-9_404-86-4.asp 7727-37-9 404-86-4
404-86.asp 404-86-4
404-86-4.asp 404-86-4
404-86.asp 404-86-4
404-86-4_57-55-6.asp 404-86-4 57-55-6
404-86.asp 404-86-4
404-86-4.asp 404-86-4
7727-37-9_592-41-6_78-78-4_7688-21-3_4050-45-7_760-21-4_110-54.asp 7727-37-9 592-41-6 78-78-4 7688-21-3 4050-45-7 760-21-4 110-54-3 107-83-5
74-85-1_74-84-0_7727-37-9_106-98-9_592-41-6_109-66-0_4050-45.asp 74-85-1 74-84-0 7727-37-9 106-98-9 592-41-6 109-66-0 4050-45-7 7688-21-3
40615-36-9.asp 40615-36-9
407-25-0.asp 407-25-0
407-25-0_7664-39.asp 407-25-0 7664-39-3
407-25.asp 407-25-0
407-25.asp 407-25-0
760572214.asp N/A
7732-16-5_497-19-8_107-21-1_1310-58-3_4080-31-3_100-97-0_542-75-6.asp 7732-16-5 497-19-8 107-21-1 1310-58-3 4080-31-3 100-97-0 542-75-6 75-09-2 144-55-8
1344-28-1_4080-31-3_9004-67-5.asp 1344-28-1 4080-31-3 9004-67-5
52640-81-0_7778-18-9_7732-18-5_13463-67-7_141-32-2_4080-31.asp 52640-81-0 7778-18-9 7732-18-5 13463-67-7 141-32-2 4080-31-3
27176-87-0_9004-08-4_127087-87-0_68603-42-9_1310-73-2_4080-31-3.asp 27176-87-0 9004-08-4 127087-87-0 68603-42-9 1310-73-2 4080-31-3
1330-43-4_292601-83-3_929-06-6_102-71-6_4080-31.asp 1330-43-4 292601-83-3 929-06-6 102-71-6 4080-31-3
144-55-8_497-19-8_4080-31-3_7732-18.asp 144-55-8 497-19-8 4080-31-3 7732-18-5
4080-31-3_100-97-0_542-75-6_75-09-2_144-55.asp 4080-31-3 100-97-0 542-75-6 75-09-2 144-55-8
7732-18-5_102-71-6_4080-31-3.asp 7732-18-5 102-71-6 4080-31-3
112-34-5_4080-31.asp 112-34-5 4080-31-3
40876-98.asp 40876-98-0
4089-07.asp 4089-07-0
01-05-0_41044-12-6.asp 01-05-0 41044-12-6
41122-70-7_64-17-5.asp 41122-70-7 64-17-5
41122-70-7.asp 41122-70-7
01-05-0_41175-45-5.asp 01-05-0 41175-45-5
01-05-0_41267-76-9.asp 01-05-0 41267-76-9
4131-74.asp 4131-74-2
4131-74-2.asp 4131-74-2
41621-49-2_100-51-6_1338-41-6_112-72-1_9005-67-8_68155-06.asp 41621-49-2 100-51-6 1338-41-6 112-72-1 9005-67-8 68155-06-6 8042-47-5 124-29-8 112-92-5 5333-42-6
123-73-9_4170-30.asp 123-73-9 4170-30-3
4170-30.asp 4170-30-3
4170-30.asp 4170-30-3
4170-30-3.asp 4170-30-3


HBCChem,Inc

Chemical Information Net chemcas.orgCopyright Reserved

Trading Lead

Leputech HPLC Laboratory