LOCTITE CORPORATION 07/02/97
ROCKY HILL, CONNECTICUT 06067
EMERGENCY PHONE: (860) 571-5100
MATERIAL SAFETY DATA SHEET Page 01 of 05
LOCQUIC(R) PRIMER N 7649
21348
1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
Product Name: LOCQUIC(R) PRIMER N 7649
Item No.: 21348
Product Type: Aerosol accelerator
2. COMPOSITION, INFORMATION ON INGREDIENTS
Ingredients CAS No. %
ACETONE 67-64-1 75-80
ISOBUTANE 75-28-5 20-25
2-Ethylhexanoic acid 149-57-5 0.1-1
Organo-copper compound 22221-10-9 0.1-1
Trialkylammonium Carboxylate 58823-74-8 0.1-1
Ingredients which have exposure limits
Exposure Limits (TWA) ACGIH OSHA OTHER
Ingredients (TLV) (PEL)
ACETONE 750 ppm TWA 750 ppm TWA None
1780 mg/m3 1800 mg/m3
Organo-copper compound Cu 0.2mg/m3fume Cu 0.1mg/m3 None
Cu 1 mg/m3 dust Cu 1 mg/m3 dust
Exposure Limits (STEL) ACGIH OSHA
Ingredients (TLV) (PEL)
ACETONE 1000 ppm 1000 ppm
2380 mg/m3 2400 mg/m3
3. HAZARDS IDENTIFICATION
Toxicity: Harmful if inhaled or swallowed.
Possible eye and respiratory irritant.
Narcotic at high concentrations.
Prolonged inhalation may cause headaches.
Moderately toxic by ingestion
Liquid may defat skin.
Primary Routes of Entry: Inhalation, ingestion, contact.
Signs and symptoms
of Exposure: Vapors irritate eyes, nose and throat.
Liquid is an eye irritant and may irritate skin.
Existing Conditions
Aggravated by Exposure: None known
LOCTITE CORPORATION 07/02/97
ROCKY HILL, CONNECTICUT 06067
EMERGENCY PHONE: (860) 571-5100
MATERIAL SAFETY DATA SHEET Page 02 of 05
Product Name: LOCQUIC(R) PRIMER N 7649
Item No.: 21348
3. HAZARDS IDENTIFICATION (continued)
Literature Referenced Carcinogen
Ingredients Target Organ and Other Health Effects NTP IARC OSHA
ACETONE BLO CNS IRR NO NO NO
ISOBUTANE CAR CNS LUN NO NO NO
2-Ethylhexanoic acid IRR NO NO NO
Organo-copper compound No Data NO NO NO
Trialkylammonium Carboxylate No Data NO NO NO
-------------------------------------------------------------------------------
Abbreviations
BLO Blood CAR Cardiac
CNS Central nervous system IRR Irritant
LUN Lung
4. FIRST AID MEASURES
Ingestion: Give water to dilute. Do not induce vomiting.
Keep individual calm. Obtain medical attention.
Inhalation: Remove to fresh air. If symptoms persist, obtain
medical attention.
Skin Contact: Wash with soap and water.
Eye Contact: Flush with water for at least 15 minutes. Obtain
medical attention.
5. FIRE FIGHTING MEASURES
Flash Point: Approximately -4癋(Base) Method: Tag Closed Cup
Recommended
Extinguishing Agents: Carbon dioxide, foam, dry chemical
Hazardous Products formed
by Fire or Thermal Decomp Irritating organic vapors
Unusual Fire or
Explosion Hazards: Cans may burst in fires.
Explosive Limits:
(% by volume in air)Lower Acetone: 2.6%
Isobutane: 1.8%
(% by volume in air)Upper Acetone: 13%
Isobutane: 8.4%
6. ACCIDENTAL RELEASE MEASURES
Steps to be taken in case
of spill or leak: Avoid flame and sparks. Maintain adequate
ventilation. Soak up in an inert absorbent and
LOCTITE CORPORATION 07/02/97
ROCKY HILL, CONNECTICUT 06067
EMERGENCY PHONE: (860) 571-5100
MATERIAL SAFETY DATA SHEET Page 03 of 05
Product Name: LOCQUIC(R) PRIMER N 7649
Item No.: 21348
6. ACCIDENTAL RELEASE MEASURES (continued)
store in a closed container until disposal.
7. HANDLING AND STORAGE
Safe Storage: Store away from flame and sparks and below 120F
(Contact Loctite Customer Service 1-800-243-4874 for shelf Life information)
Handling: Avoid prolonged breathing of fumes. Avoid skin
or eye contact. Do not use near heat, sparks, or
open flame.
8. EXPOSURE CONTROLS, PERSONAL PROTECTION
Eyes: Safety glasses or goggles.
Skin: Rubber or plastic gloves.
Ventilation: Sufficient to maintain vapor concentration
below TLV.
See Section 2 for Exposure Limits.
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance: Green liquid (Base only)
Odor: Acetone
Boiling Point: 133癋 (Base only)
pH: Does not apply
Solubility in Water: Miscible
Specific Gravity 0.7936 (Base only)
Volatile Organic Compound
(EPA Method 24) 1.48%;11.7 grams per liter of material (Base only)
Vapor Pressure: Approximately 172 mm Hg at 68癋 (Base only)
Vapor Density: Not available
Evaporation Rate
(Ether = 1) 1.9 (Base only)
10. STABILITY AND REACTIVITY
Stability: Stable
Hazardous Polymerization: Will not occur
Incompatibility: Strong oxidizers, peroxides
Conditions to Avoid: Not available
Hazardous Decomposition
Products (non-thermal): None
11. TOXICOLOGICAL INFORMATION
See Section 3.
LOCTITE CORPORATION 07/02/97
ROCKY HILL, CONNECTICUT 06067
EMERGENCY PHONE: (860) 571-5100
MATERIAL SAFETY DATA SHEET Page 04 of 05
Product Name: LOCQUIC(R) PRIMER N 7649
Item No.: 21348
12. ECOLOGICAL INFORMATION
No data available
13. DISPOSAL CONSIDERATIONS
Recommended methods of
disposal: Use disposal service licensed to handle flammable
aerosols.
EPA Hazardous Waste
Number D001 - Hazardous waste per 40CFR 261.21
14. TRANSPORTATION INFORMATION
DOT (49 CFR 172)
Domestic Ground Transport
Proper Shipping Name: Consumer Commodity
Hazard Class or
Division: ORM-D
Identification Number: None
Marine Pollutant: None
IATA
Proper Shipping Name: Aerosols, flammable, n.o.s.
Class or Division: Division 2.1
UN or ID Number: UN 1950
15. REGULATORY INFORMATION
CA Proposition 65: WARNING: This product contains a chemical known to
the State of California to cause cancer
and birth defects or other reproductive
harm.
Traces of lead and nickel
16. OTHER INFORMATION
Estimated NFPA(R) Code:
Health Hazard: 2
Fire Hazard: 4
Reactivity Hazard: 0
Specific Hazard: Does not apply
Estimated HMIS(R) Code:
Health Hazard: 2
Flammability Hazard: 4
Reactivity Hazards: 0
Personal Protection: See Section 8.
NFPA is a registered trademark of the National Fire Protection Assn.
HMIS is a registered trademark of the National Paint and Coatings Assn.
LOCTITE CORPORATION 07/02/97
ROCKY HILL, CONNECTICUT 06067
EMERGENCY PHONE: (860) 571-5100
MATERIAL SAFETY DATA SHEET Page 05 of 05
Product Name: LOCQUIC(R) PRIMER N 7649
Item No.: 21348
16. OTHER INFORMATION (continued)
Prepared By: Stephen Repetto
Title: Research Chemist, Environmental Health & Safety
Company: Loctite Corp., 1001 Tr Br Cr, Rocky Hill CT 06067
(24hr.) Phone: (860) 571-5100
Revision Date: January 22, 1996 Revision: 0004
|