Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

7440-70-2 7440-21-3 7440-39-3 7429-90-5 7440-47-3 7440-02-0

File Name: 7440-70-2_7440-21-3_7440-39-3_7429-90-5_7440-47-3_7440-02-0.asp

ELKEM METALS  -- CALCIUM-SILICON ALLOYS, HYPERCAL ALLOY 
MATERIAL SAFETY DATA SHEET
FSC: 3439
NIIN: 00N044298
Manufacturer's CAGE: 1DS52
Part No. Indicator: A
Part Number/Trade Name: CALCIUM-SILICON ALLOYS, HYPERCAL ALLOY
===========================================================================
General Information
===========================================================================
Company's Name: ELKEM METALS CO *
Company's P. O. Box: 1344 *
Company's City: NIAGARA FALLS *
Company's State: NY *
Company's Country: US *
Company's Zip Code: 14302 *
Company's Emerg Ph #: 716-286-7548;800-424-9300(CHEMTREC) *
Company's Info Ph #: 716-286-7548 *
Safety Data Action Code: C
Record No. For Safety Entry: 001
Tot Safety Entries This Stk#: 001
Status: SMJ *
Date MSDS Prepared: 01DEC85 *
Safety Data Review Date: 18OCT95 *
MSDS Serial Number: BTLTX
Hazard Characteristic Code: N1 *
===========================================================================
Ingredients/Identity Information
===========================================================================
Proprietary: NO
Ingredient: CALCIUM
Ingredient Sequence Number: 01
Percent: 10-32
NIOSH (RTECS) Number: EV8040000
CAS Number: 7440-70-2
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
-------------------------------------
Proprietary: NO
Ingredient: SILICON
Ingredient Sequence Number: 02
Percent: 38-65
NIOSH (RTECS) Number: VW0400000
CAS Number: 7440-21-3
OSHA PEL: 10 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
-------------------------------------
Proprietary: NO
Ingredient: BARIUM
Ingredient Sequence Number: 03
Percent: 0-18
NIOSH (RTECS) Number: CQ8370000
CAS Number: 7440-39-3
OSHA PEL: 0.5 MG/M3
ACGIH TLV: 0.5 MG/M3
-------------------------------------
Proprietary: NO
Ingredient: ALUMINUM
Ingredient Sequence Number: 04
Percent: 1-21
NIOSH (RTECS) Number: BD0330000
CAS Number: 7429-90-5
OSHA PEL: 15MG/M3 DUST;5 FUME
ACGIH TLV: 10MG/M3 DUST
-------------------------------------
Proprietary: NO
Ingredient: CHROMIUM
Ingredient Sequence Number: 05
Percent: <0.5
NIOSH (RTECS) Number: GB4200000
CAS Number: 7440-47-3
OSHA PEL: 1 MG/M3
ACGIH TLV: 0.5 MG/M3
-------------------------------------
Proprietary: NO
Ingredient: NICKEL
Ingredient Sequence Number: 06
Percent: <0.5
NIOSH (RTECS) Number: QR5950000
CAS Number: 7440-02-0
OSHA PEL: 1 MG/M3
ACGIH TLV: 1 MG/M3
-------------------------------------
Proprietary: NO
Ingredient: EXPLAN OF CARCIN: TO MAN, VOL 49, PG 257, 1990: GRP 2B. NTP
6TH ANNUAL RPT ON CARCIN, 1991: ANTIC TO BE CARCIN.
Ingredient Sequence Number: 07
NIOSH (RTECS) Number: 9999999ZZ
OSHA PEL: NOT APPLICABLE
ACGIH TLV: NOT APPLICABLE
===========================================================================
Physical/Chemical Characteristics
===========================================================================
Appearance And Odor: GREY METALLIC, ODORLESS *
Boiling Point: N/K *
Melting Point: SUPP DATA *
Vapor Pressure (MM Hg/70 F): N/K *
Vapor Density (Air=1): N/K *
Specific Gravity: 2.0-2.5 *
Decomposition Temperature: N/K *
Evaporation Rate And Ref: N/K *
Solubility In Water: INSOLUBLE *
Percent Volatiles By Volume: N/K *
pH: N/K *
Corrosion Rate (IPY): N/K *
===========================================================================
Fire and Explosion Hazard Data
===========================================================================
Flash Point: N/K *
Flash Point Method: N/P *
Lower Explosive Limit: N/K *
Upper Explosive Limit: N/K *
Extinguishing Media: CLASS D FIRES: USE DRY CHEM, DRY SAND/CARBON DIOXIDE
TO SMOTHER FIRE. FIRE MAY ALSO BE ISOLATED & ALLOWED TO (SUPP DATA) *
Special Fire Fighting Proc: WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT (FP N). *
Unusual Fire And Expl Hazrds: BASED UPON COMBUSTIBILITY TESTS, FINE MATL
IS CONSIDERED VERY ACTIVE. CONCS OF ALLOY DUST, WHEN SUSPENDED IN AIR, CAN
BE IGNITED, PROPAGATE FLAME (SUPP DATA) *
===========================================================================
Reactivity Data
===========================================================================
Stability: YES *
Cond To Avoid (Stability): PRLNGD CONT W/MOISTURE DURING STOR.VENT SHOULD
BE SUPPLIED IN AREAS OF EXTENDED STOR.AVOID GENERATION OF AIRBORNE DUSTS. *
Materials To Avoid: MOISTURE, ACIDS. *
Hazardous Decomp Products: SM AMTS OF ARSINE, PHOSPHINE, & HYDROGEN MAY
EVOLVE IF MOISTURE IS PRESENT. RXN W/ACIDS CAN PRDCE SILANES (SUPP DATA) *
Hazardous Poly Occur: NO *
Conditions To Avoid (Poly): NOT RELEVANT *
===========================================================================
Health Hazard Data
===========================================================================
LD50-LC50 Mixture: NONE SPECIFIED BY MANUFACTURER. *
Route Of Entry - Inhalation: YES *
Route Of Entry - Skin: NO *
Route Of Entry - Ingestion: NO *
Health Haz Acute And Chronic: ACUTE: ALLOYS ARE OF LOW TOXICITY IN LUMP
FORM AND NO RESIDUAL INJURY IS EXPECTED. HIGH CONCENTRATION OF METALLIC
DUST MAY CAUSE SOME IRRITATION TO EYE, NOSE AND THROAT. CHRONIC: NO
RESIDUAL INJURY IS EXPECTED. *
Carcinogenicity - NTP: NO *
Carcinogenicity - IARC: YES *
Carcinogenicity - OSHA: NO *
Explanation Carcinogenicity: CHROMIUM: IARC MONOGRAPHS, VOL 49, PG 49,
1990:GRP 1. NTP 6TH ANNUAL RPT ON CARCINS, 1991: KNOWN TO BE CARCIN.
(SUPDAT) *
Signs/Symptoms Of Overexp: SEE HEALTH HAZARDS. *
Med Cond Aggravated By Exp: NONE SPECIFIED BY MANUFACTURER. *
Emergency/First Aid Proc: INHAL: REMOVE FROM DUSTY AREA TO FRESH AIR.
SKIN: NO HAZARD ASSOCIATED W/SKIN CONTACT. FLUSH WITH COPIOUS AMOUNTS OF
WATER. CALL MD (FP N). EYE: FLUSH WITH WATER FOR AT LEAST 15 MINUTES TO BE
SURE THAT NO PARTICLES REMAIN IN EYE. INGEST: CALL MD IMMED (FP N). *
===========================================================================
Precautions for Safe Handling and Use
===========================================================================
Steps If Matl Released/Spill: AVOID USING COMPRESSED AIR TO MANEUVER
SPILLS/LEAKS OF FINE MATERIAL. FINE MATERIAL SHOULD BE SWEPT UP/VACUUMED.
NO PROBLEM IS ASSOCIATED WITH SPILLS/LEAKS OF LUMP MATERIAL. KEEP WET
MATERIAL SEPARATED FROM DRY MATERIAL. *
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER. *
Waste Disposal Method: AVOID REPACKING WET MATERIAL IN SEALED CONTAINERS.
DISPOSE OF I/A/W APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS. *
Precautions-Handling/Storing: EXCLUDE CONT W/MOISTURE & ACIDS AS MUCH AS
POSS. CALCIUM-SILICON ALLOYS SHOULD BE KEPT AWAY FROM SPARKS, HEAT & OPEN
FLAMES IN A WELL VENTD AREA. *
Other Precautions: MILLING: SPECIAL PREC, SUCH AS USE OF INERT ATMOSPHERE,
SHOULD BE USED WHEN SIZING TO MINUS 8 MESH. MINIMIZE AND CONTROL DUSTY
OPERATIONS. GRINDING WET MATL MAY BE HAZ DUE TO THE POSSIBILITY OF HYDROGEN
EVOLUTION. *
===========================================================================
Control Measures
===========================================================================
Respiratory Protection: IN DUSTY AREAS, USE NIOSH/MSHA APPROVED SCHEDULE
21C RESPIRATOR. *
Ventilation: LOCAL FOR DUSTY AREAS. PROVIDE VENTILATION DURING STORAGE OR
HANDLING OF MOIST MATERIAL. *
Protective Gloves: IMPERVIOUS GLOVES (FP N). *
Eye Protection: ANSI APVD CHEMICAL SAFETY GOGGLES (FP N) *
Other Protective Equipment: AS WITH OTHER METAL DUSTS AVOID CONTAMINATION
OF WORK CLOTHING. *
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER. *
Suppl. Safety & Health Data: MP:>1292F,>700C. EXTING MEDIA: BURN ITSELF
OUT. DO NOT DISTURB METAL WHILE EXTING FIRE. EXPLO HAZ: READILY, GENERATE
IARC MONOGRAPHS ON EVAL OF CARCIN RISK OF CHEM (ING 7) *
===========================================================================
Transportation Data
===========================================================================
===========================================================================
Disposal Data
===========================================================================
===========================================================================
Label Data
===========================================================================
Label Required: YES
Label Status: G
Common Name: CALCIUM-SILICON ALLOYS, HYPERCAL ALLOY
Special Hazard Precautions: ACUTE: ALLOYS ARE OF LOW TOXICITY IN LUMP FORM
AND NO RESIDUAL INJURY IS EXPECTED. HIGH CONCENTRATION OF METALLIC DUST MAY
CAUSE SOME IRRITATION TO EYE, NOSE AND THROAT. CHRONIC: NO RESIDUAL INJURY
IS EXPECTED. SEE HEALTH HAZARDS.
Label Name: ELKEM METALS CO
Label P.O. Box: 1344
Label City: NIAGARA FALLS
Label State: NY
Label Zip Code: 14302
Label Country: US
Label Emergency Number: 716-286-7548;800-424-9300(CHEMTREC)
=======================================================================
URL for this msds http://hazard.com. If you wish to change, add to, or
delete information in this archive please sent updates to dan@hazard.com.
Search    ENTER KEYWORD
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
63148-62-9_112945-52-5_17689-77-9_4253-34-3_13463-67-7_64-19.asp 63148-62-9 112945-52-5 17689-77-9 4253-34-3 13463-67-7 64-19-7
63148-62-9_112945-52-5_17689-77-9_4253-34-3_64-19.asp 63148-62-9 112945-52-5 17689-77-9 4253-34-3 64-19-7
n37187016.asp N/A
n443580795.asp N/A
n845233275.asp N/A
71-36-3.asp 71-36-3
n839848978.asp N/A
1492178500.asp N/A
1330-20-7_108-88-3_64-17-5_95-63-6_71-43-2_100-41-4_110-54.asp 1330-20-7 108-88-3 64-17-5 95-63-6 71-43-2 100-41-4 110-54-3 110-82-7 91-20-3
888-00-0_110-54-3_8012-95-1_71-43-2_1317-65-3.asp 888-00-0 110-54-3 8012-95-1 71-43-2 1317-65-3
n1687332145.asp N/A
1610562798.asp N/A
270980567.asp N/A
n379409109.asp N/A
71-55-6.asp 71-55-6
64475-85-0_71-55-6.asp 64475-85-0 71-55-6
71-55-6_63449-39-8_8016-28-2_109-87-5_75-65-0_106-88-7_119-36-8.asp 71-55-6 63449-39-8 8016-28-2 109-87-5 75-65-0 106-88-7 119-36-8 03-05-8
71-55-6_8030-30-6_108-88-3_124-38-9.asp 71-55-6 8030-30-6 108-88-3 124-38-9
1265949087.asp N/A
54395.asp N/A
1974381937.asp N/A
1135166762.asp N/A
1317-36-8_7758-97-6_7446-14-2_10190-55-3_1344-37-2_12656-85.asp 1317-36-8 7758-97-6 7446-14-2 10190-55-3 1344-37-2 12656-85-8 18454-12-1 7319-86-0 301-08-6 1314-41-6 10099-74-8 61790-14-5 1309-60-0 1319-46-6
51274-00-1_14808-60-7_20344-49-4_7440-38-2_7440-43-9_7440-02-0.asp 51274-00-1 14808-60-7 20344-49-4 7440-38-2 7440-43-9 7440-02-0 7439-92-1 62-53-3
7440-70-2_7440-21-3_7440-39-3_7429-90-5_7440-47-3_7440-02-0.asp 7440-70-2 7440-21-3 7440-39-3 7429-90-5 7440-47-3 7440-02-0
n1404540820.asp N/A
75-74-1_78-00-2_1163-19-5_25637-99.asp 75-74-1 78-00-2 1163-19-5 25637-99-4
7447-40-7_7778-53-2.asp 7447-40-7 7778-53-2
301341-58-2_7778-80-5_61789-30-8_7447-40.asp 301341-58-2 7778-80-5 61789-30-8 7447-40-7
75-05-8.asp 75-05-8
n1717798250.asp N/A
00075-07-0.asp 00075-07-0
14567-73-8_17068-78-9_108-05-4_75-07-0_7732-18.asp 14567-73-8 17068-78-9 108-05-4 75-07-0 7732-18-5
1317-65-3_13463-67-7_14808-60-7_1333-86-4_7664-41-7_75-07.asp 1317-65-3 13463-67-7 14808-60-7 1333-86-4 7664-41-7 75-07-0 107-13-1 50-00-0 79-06-1
96828-31-8_140-88-5_79-41-5_67-64-1_75-65-0_50-00-0_75-07.asp 96828-31-8 140-88-5 79-41-5 67-64-1 75-65-0 50-00-0 75-07-0
75-09.asp 75-09-2
108-88-3_75-09-2_67-64-1_74-98-6_1330-20-7.asp 108-88-3 75-09-2 67-64-1 74-98-6 1330-20-7
75-09-2.asp 75-09-2
00075-15-0.asp 00075-15-0
75-45.asp 75-45-6
75-10-5_75-45-6_75-71-8_74-87-3_75-43.asp 75-10-5 75-45-6 75-71-8 74-87-3 75-43-4
75-52-5_78-93-3.asp 75-52-5 78-93-3
n1557598521.asp N/A
00075-56-9.asp 00075-56-9
00075-65-0.asp 00075-65-0
75-71-8.asp 75-71-8
67-64-1_74-98-6_107-83-5_110-82-7_96-14-0_75-83-2_79-29-8_110-54.asp 67-64-1 74-98-6 107-83-5 110-82-7 96-14-0 75-83-2 79-29-8 110-54-3
994-05-8_67-56-1_563-46-2_513-35.asp 994-05-8 67-56-1 563-46-2 513-35-9
00094-36-0.asp 00094-36-0
n845233275.asp N/A


HBCChem,Inc

Chemical Information Net chemcas.orgCopyright Reserved

Trading Lead

Leputech HPLC Laboratory