Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

7790-80-9
007-00-8

File Name: AA35683-03.asp

                                                                       Page 1/8
Material Safety Data Sheet
acc. to OSHA and ANSI
Printing date 03/15/2005 Reviewed on 12/01/2004

1 Identification of substance:
Product details:
Product name: Cadmium iodide
Stock number: 35683
Manufacturer/Supplier:
Alfa Aesar, A Johnson Matthey Company
Johnson Matthey Catalog Company, Inc.
30 Bond Street
Ward Hill, MA 01835-8099
Emergency Phone: (978) 521-6300
CHEMTREC: (800) 424-9300
Web Site: www.alfa.com
Information Department: Health, Safety and Environmental Department
Emergency information:
During normal hours the Health, Safety and Environmental
Department. After normal hours call Chemtrec at (800) 424-9300.

2 Composition/Data on components:
Chemical characterization:
Description: (CAS#)
Cadmium iodide (CAS# 7790-80-9); 100%
Identification number(s):
EINECS Number: 232-223-6
EU Number: 048-007-00-8

3 Hazards identification
Hazard description:

T Toxic
N Dangerous for the environment

Information pertaining to particular dangers for man and
environment
R 23/25 Toxic by inhalation and if swallowed.
R 33 Danger of cumulative effects.
R 68 Possible risk of irreversible effects.
R 50/53 Very toxic to aquatic organisms, may cause long-term
adverse effects in the aquatic environment
Classification system
HMIS ratings (scale 0-4)
(Hazardous Materials Identification System)
HEALTH 3 Health (acute effects) = 3
Flammability = 0
FIRE 0
Reactivity = 1
REACTIVITY 1

USA
(Contd. on page 2)




DR
Page 2/8
Material Safety Data Sheet
acc. to OSHA and ANSI
Printing date 03/15/2005 Reviewed on 12/01/2004

Product name: Cadmium iodide

(Contd. of page 1)

4 First aid measures
General information
Immediately remove any clothing soiled by the product.
Remove breathing apparatus only after contaminated clothing has
been completely removed.
In case of irregular breathing or respiratory arrest provide
artificial respiration.
After inhalation
Supply fresh air. If required, provide artificial respiration. Keep
patient warm.
Seek immediate medical advice.
After skin contact
Immediately wash with water and soap and rinse thoroughly.
Seek immediate medical advice.
After eye contact
Rinse opened eye for several minutes under running water. Then
consult a doctor.
After swallowing
Do not induce vomiting; immediately call for medical help.
Seek immediate medical advice.

5 Fire fighting measures
Suitable extinguishing agents
Product is not flammable. Use fire fighting measures that suit the
surrounding fire.
Special hazards caused by the material, its products of combustion
or resulting gases:
In case of fire, the following can be released:
Hydrogen iodide (HI)
Toxic metal oxide fume
Protective equipment:
Wear self-contained respirator.
Wear fully protective impervious suit.

6 Accidental release measures
Person-related safety precautions:
Wear protective equipment. Keep unprotected persons away.
Ensure adequate ventilation
Measures for environmental protection:
Do not allow material to be released to the environment without
proper governmental permits.
Measures for cleaning/collecting:
Dispose contaminated material as waste according to item 13.
Ensure adequate ventilation.
Additional information:
See Section 7 for information on safe handling
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.
USA
(Contd. on page 3)




DR
Page 3/8
Material Safety Data Sheet
acc. to OSHA and ANSI
Printing date 03/15/2005 Reviewed on 12/01/2004

Product name: Cadmium iodide

(Contd. of page 2)

7 Handling and storage
Handling
Information for safe handling:
Keep container tightly sealed.
Store in cool, dry place in tightly closed containers.
Ensure good ventilation at the workplace.
Open and handle container with care.
Prevent formation of dust.
Information about protection against explosions and fires:
The product is not flammable
Storage
Requirements to be met by storerooms and receptacles:
No special requirements.
Information about storage in one common storage facility:
Not required.
Further information about storage conditions:
This product is hygroscopic.
Keep container tightly sealed.
Store in cool, dry conditions in well sealed containers.
Store under lock and key and with access restricted to technical
experts or their assistants only.

8 Exposure controls and personal protection
Additional information about design of technical systems:
Properly operating chemical fume hood designed for hazardous
chemicals and having an average face velocity of at least 100 feet
per minute.
(Contd. on page 4)
USA




DR
Page 4/8
Material Safety Data Sheet
acc. to OSHA and ANSI
Printing date 03/15/2005 Reviewed on 12/01/2004

Product name: Cadmium iodide

(Contd. of page 3)
Components with limit values that require monitoring at the
workplace:

Cadmium and compounds, as Cd
mg/m3
ACGIH TLV 0.01; Suspected human carcinogen
Austria Carcinogen
Belgium TWA 0.05
Denmark TWA 0.01
Finland TWA 0.02; Carcinogen
France VME 0.05
Germany Carcinogen
Ireland TWA 0.025; Carcinogen
Japan OEL 0.05; Group 1 carcinogen
Korea TLV 0.01; Suspected human carcinogen
Netherlands MAC-TGG 0.02; 0.1-MAC-K
Norway TWA 0.05
Poland TWA 0.02; 0.05-STEL (fume)
Poland TWA 0.04; 0.2-STEL (dust)
Russia 0.01; 0.05-STEL
Sweden NGV 0.05 (total dust)
Sweden TWA 0.01 (resp. dust)
Switzerland MAK-W 0.05; Carcinogen
United Kingdom TWA 0.025
USA PEL 0.005
Additional information: No data
Personal protective equipment
General protective and hygienic measures
The usual precautionary measures for handling chemicals should be
followed.
Keep away from foodstuffs, beverages and feed.
Remove all soiled and contaminated clothing immediately.
Wash hands before breaks and at the end of work.
Store protective clothing separately.
Breathing equipment:
Use suitable respirator when high concentrations are present.
Refer to 29CFR1910.1027 for regulations on respiratory protection
required during exposure to cadmium and cadmium compounds.
Protection of hands: Impervious gloves
Eye protection: Safety glasses
Body protection: Protective work clothing.

9 Physical and chemical properties:
General Information
Form: Powder
Color: Light green
Odor: Odorless
Change in condition
Melting point/Melting range: 387掳C (729掳F)
Boiling point/Boiling range: 796掳C (1465掳F)
(Contd. on page 5)
USA




DR
Page 5/8
Material Safety Data Sheet
acc. to OSHA and ANSI
Printing date 03/15/2005 Reviewed on 12/01/2004

Product name: Cadmium iodide

(Contd. of page 4)
Sublimation temperature /
start: Not determined
Flash point: Not applicable
Ignition temperature: Not determined
Decomposition temperature: Not determined
Danger of explosion: Product does not present an
explosion hazard.
Explosion limits:
Lower: Not determined
Upper: Not determined
Vapor pressure: Not determined
Density: Not determined
Solubility in / Miscibility with
Water: Soluble


10 Stability and reactivity
Thermal decomposition / conditions to be avoided:
Decomposition will not occur if used and stored according to
specifications.
Materials to be avoided: Water/moisture
Dangerous reactions No dangerous reactions known
Dangerous products of decomposition:
Hydrogen iodide (HI)
Toxic metal oxide fume

11 Toxicological information
Acute toxicity:
LD/LC50 values that are relevant for classification:
Oral LD50 166 mg/kg (mus)
222 mg/kg (rat)
LDLo 81 mg/kg (hmn)
Primary irritant effect:
on the skin: Irritant to skin and mucous membranes.
on the eye: Irritating effect.
Sensitization: No sensitizing effects known.
Subacute to chronic toxicity:
Cadmium and cadmium compounds are highly toxic and experimental
carcinogens. Exposure affects the respiratory tract, kidneys, and
liver. Ingestion may cause nausea, salivation, vomiting and
diarrhea. Ingestion or inhalation of cadmium/cadmium compounds may
be fatal.
(Contd. on page 6)
USA




DR
Page 6/8
Material Safety Data Sheet
acc. to OSHA and ANSI
Printing date 03/15/2005 Reviewed on 12/01/2004

Product name: Cadmium iodide

(Contd. of page 5)
Prolonged exposure to iodides may cause skin rash, running nose,
headache and irritation of the mucous membranes. In severe cases
the skin may show pimples, boils, redness, black and blue spots,
hives and blisters. Iodides are readily diffused across the
placenta.
Additional toxicological information:
To the best of our knowledge the acute and chronic toxicity of this
substance is not fully known.
EPA-B1: Probable human carcinogen, limited evidence of
carcinogenicity from epidemiologic studies.
IARC-1: Carcinogenic to humans: sufficient evidence of
carcinogenicity.
NTP-2: Reasonably anticipated to be a carcinogen: limited evidence
from studies in humans or sufficient evidence from studies in
experimental animals.
Carcinogen as defined by OSHA.
ACGIH A2: Suspected human carcinogen: Agent is carcinogenic in
experimental animals at dose levels, by route(s) of administration,
at site(s), of histologic type(s), or by mechanism(s) considered
relevant to worker exposure. Available epidemiologic studies are
conflicting or insufficient to confirm an increased risk of cancer
in exposed humans.
The Registry of Toxic Effects of Chemical Substances (RTECS)
contains tumorigenic and/or carcinogenic and/or neoplastic data for
components in this product.

12 Ecological information:
Ecotoxical effects:
Remark: Very toxic for fish
General notes:
Also poisonous for fish and plankton in water bodies.
Do not allow material to be released to the environment without
proper governmental permits.
Very toxic for aquatic organisms

13 Disposal considerations
Product:
Recommendation
Consult state, local or national regulations to ensure proper
disposal.
Uncleaned packagings:
Recommendation:
Disposal must be made according to official regulations.
Recommended cleansing agent:
Water, if necessary with cleansing agents.
USA
(Contd. on page 7)




DR
Page 7/8
Material Safety Data Sheet
acc. to OSHA and ANSI
Printing date 03/15/2005 Reviewed on 12/01/2004

Product name: Cadmium iodide

(Contd. of page 6)

14 Transport information
DOT regulations:




Hazard class: 6.1
Identification number: UN2570
Packing group: III
Proper shipping name (technical
name): Cadmium compound, cadmium iodide
Land transport ADR/RID (cross-border)




ADR/RID class: 6.1 Toxic substances
Item: 61c
Danger code (Kemler): 60
UN-Number: 2570
Description of goods: Cadmium compound, cadmium iodide
Maritime transport IMDG:




IMDG Class: 6.1
UN Number: 2570
Packaging group: III
Proper shipping name: Cadmium compound, cadmium iodide
Air transport ICAO-TI and IATA-DGR:




ICAO/IATA Class: 6.1
UN/ID Number: 2570
Packaging group: III
Proper shipping name: Cadmium compound, cadmium iodide


15 Regulations
Product related hazard informations:
Hazard symbols:
T Toxic
N Dangerous for the environment
Risk phrases:
23/25 Toxic by inhalation and if swallowed.
(Contd. on page 8)
USA



DR
Page 8/8
Material Safety Data Sheet
acc. to OSHA and ANSI
Printing date 03/15/2005 Reviewed on 12/01/2004

Product name: Cadmium iodide

(Contd. of page 7)
33 Danger of cumulative effects.
68 Possible risk of irreversible effects.
50/53 Very toxic to aquatic organisms, may cause long-term adverse
effects in the aquatic environment
Safety phrases:
22 Do not breathe dust.
45 In case of accident or if you feel unwell, seek medical advice
immediately.
60 This material and its container must be disposed of as hazardous
waste.
61 Avoid release to the environment. Refer to special instructions/
Safety data sheets
National regulations
All components of this product are listed in the U.S. Environmental
Protection Agency Toxic Substances Control Act Chemical substance
Inventory.
All components of this product are listed on the Canadian Domestic
Substances List (DSL).
Information about limitation of use:
For use only by technically qualified individuals.
This product contains cadmium and is subject to the reporting
requirements of section 313 of the Emergency Planning and Community
Right to Know Act of 1986 and 40CFR372.
Other regulations, limitations and prohibitive regulations
Refer to 29CFR1910.1027 for regulations concerning cadmium and
cadmium compounds.

16 Other information:
Employers should use this information only as a supplement to other
information gathered by them, and should make independent judgement
of suitability of this information to ensure proper use and protect
the health and safety of employees. This information is furnished
without warranty, and any use of the product not in conformance
with this Material Safety Data Sheet, or in combination with any
other product or process, is the responsibility of the user.
Department issuing MSDS:
Health, Safety and Environmental Department.
Contact: Darrell R. Sanders
USA




DR

ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
AA35644-K7.asp 7647-01-0 7732-18-5
AA35644-M4.asp 7647-01-0 7732-18-5
AA35645-K2.asp 7772-98-7 7732-18-5
AA35645-K7.asp 7772-98-7 7732-18-5
AA35645-M4.asp 7772-98-7 7732-18-5
AA35646-K2.asp 7647-01-0 7732-18-5
AA35646-K7.asp 7647-01-0 7732-18-5
AA35646-M4.asp 7647-01-0 7732-18-5
AA35647-K2.asp 7772-98-7 7732-18-5
AA35647-K7.asp 7772-98-7 7732-18-5
AA35648-K2.asp 7647-01-0 7732-18-5
AA35648-K7.asp 7647-01-0 7732-18-5
AA35648-M4.asp 7647-01-0 7732-18-5
AA35649-K2.asp 7664-93-9 7732-18-5 020-00-8
AA35649-K7.asp 7664-93-9 7732-18-5 020-00-8
AA35649-M4.asp 7664-93-9 7732-18-5 020-00-8
AA35650-K2.asp 13590-82-4 7732-18-5
AA35650-K7.asp 13590-82-4 7732-18-5
AA35651-K2.asp 7664-93-9 7732-18-5 020-00-8
AA35651-K7.asp 7664-93-9 7732-18-5 020-00-8
AA35651-M4.asp 7664-93-9 7732-18-5 020-00-8
AA35654-AP.asp 10043-52-4 7732-18-5
AA35654-K2.asp 10043-52-4 7732-18-5
AA35656-K2.asp 7758-02-3 7758-01-2 7732-18-5
AA35656-K7.asp 7758-02-3 7758-01-2 7732-18-5
AA35660-03.asp 12006-40-5 002-00-5
AA35660-06.asp 12006-40-5 002-00-5
AA35663-09.asp 12036-32-7
AA35663-18.asp 12036-32-7
AA35666-03.asp 12055-23-1 1314-23-4
AA35666-06.asp 12055-23-1 1314-23-4
AA35666-14.asp 12055-23-1 1314-23-4
AA35667-09.asp 37264-20-3
AA35667-18.asp 37264-20-3
AA35669-18.asp 7790-75-2
AA35669-30.asp 7790-75-2
AA35670-09.asp 12008-29-6
AA35670-18.asp 12008-29-6
AA35671-18.asp 12060-00-3 001-00-6
AA35671-30.asp 12060-00-3 001-00-6
AA35672-04.asp 12008-21-8
AA35672-09.asp 12008-21-8
AA35674-06.asp 7727-15-3
AA35675-06.asp 7784-23-8
AA35675-14.asp 7784-23-8
AA35681-03.asp 7787-64-6
AA35681-06.asp 7787-64-6
AA35681-14.asp 7787-64-6
AA35683-03.asp 7790-80-9 007-00-8
AA35683-06.asp 7790-80-9 007-00-8


HBCChem,Inc

Chemical Information Net chemcas.orgCopyright Reserved

Trading Lead

Leputech HPLC Laboratory